Call (888)-671-2883
FREE SHIPPING
 on most items
Text message to Live Chat! (201) 898 - 2676

DIXON A100HC96A A100 OUTALARM W/ HTEMP CAPACITANCE PROBE 96" STD 1/2NPT GLAND

BRAND: Dixon | MODEL: A100HC96A | CONDITION: NEW | SKU: 2934089
DIXON A100HC96A A100 OUTALARM W/ HTEMP CAPACITANCE PROBE 96" STD 1/2NPT GLAND

Image for Illustration purposes only,
Actual product may vary
$0.00
FREE SHIPPING
Typically In Stock: confirm availability
Returnable: see conditions
Shipping from?: see locations Typically ships in 1 day
Weight: 4.50 lbs UOM: EA
100% SAFE SHOPPING
PAYMENT METHOD
 
 

Additional Description

Technical Specifications

Length 96"

Documents

Description

Applications
  • Specifically designed for liquid terminal operation on batch loading and overfill protection, tank cars, tank trucks, marine barges, suitable for open and close dome
Specifications
  • Intrinsically safe design per ANSI/UL913 Class I, Div I Groups A, B, C and D Hazardous Areas
Features
  • Totally self-contained; no wires, tubing or external power
  • Rugged weather and corrosion resistant construction
  • No moving parts, tip sensitive phase shift™ digital capacitance sensor for conductive and non-conductive fluid
  • Requires no calibration or adjustment
  • Operates up to 2500 hours on a single 9V alkaline battery
  • Adjustable insertion length through a standard 1/2" NPT fitting
  • High intensity audible and flashing visual outputs
  • Full, hard graduated laser engraved rod
  • Fail safe continuous battery monitor goes to alarm state on low battery
  • Activation point 1/4" above liquid surface
  • Battery current drain <0.23 ma during standby; <50 ma in alarm state
  • Horn intensity 101 dB at 2'
  • Light output 3 each 3000 mcd high intensity flashing LED's
  • Capacitance Phase Shift Probe
  • 1/2 NPT gland standard
  • Minimum dielectric constant 1.7
Construction
  • Wetted materials: 316 stainless steel, PTFE standard, other materials available
Available Options
  • 24", 36", 48" and 60" probe lengths standard, other lengths available
  • Optional opto-isolated solid state contact output
Safety notes
  • WARNING: This product contains a chemical known to the State of California to cause birth defects or other reproductive harm. Do not use in connection with drinking water. Wash hands after handling.
Part Number A100HC96A
Length 96"
Pressure Rating 50 PSI, consult Dixon® for applications up to 300 PSI
Temperature Range -14°F to 325°F (-26°C to 163°C)
Optional Pkg/Box Qty 1
Weight Lb 4.5000