DTGB05504S Drive Isolation Transformer Three Phase 60 Hz 460 Delta Primary Volts 460Y/266 Secondary Volts

DTGB05504S Drive Isolation Transformer Three Phase 60 Hz 460 Delta Primary Volts 460Y/266 Secondary Volts

Image for Illustration purposes only,
Actual product may vary
Typically In Stock: confirm availability
Returnable: see conditions
Shipping from?: see locations Ships in 3 days
Weight: 2,580.00 lbs UOM: EA

Additional Description




A three leg wound center is used by all our DITs. This first-class layout has silent operation and really low losses. These two characteristics combine to reduce procedure costs and losses in comparison with other kinds of structures. All Acme DITs including the 220kVA and up to have copper conclusions. The transition from aluminum strip coil conductors to copper conclusions is carried through by a bonding procedure called "Koldwelding" This procedure was used by Acme for over 25 years to supply a trouble free, long-term bonding of both metals.

180°C and 220°C insulating material systems
Acme’s reinforced silent functioning is enhanced by center assemblies
Designed to be used with flexible frequency, AC or DC drives
Total capability pat are featured on all units. Taps are 2-2 1/2% ANFC and 2-2 1/2% BNFC.
All conventional drive systems are covered by complete variety of kVA evaluations
Considerable wiring compartment for easy cable entrance
Optional wall mounting brackets for specific sizes
Strain alleviation: Acme uses strip conductors (above 7.5 kVA) instead of wire for a DIT string that readily adapts the acute electric and mechanical stresses seen in now’s AC & DC motor drives. The built-in outstanding line isolation of these transformers is further improved with the additional protection of Acme’s Electrostatic Shield — .
Lower reductions: The harmonic currents produced by AC & DC drives raise eddy current losses (heat) in transformer windings. The thicker the greater the reductions, the winding conductor. Acme uses one turn per layer of thin strip conductor which supplies lower eddy current losses than wire wound units that are similar. Reductions that are lower = longer transformer life and cooler operation.
For additional protection all layouts 7.5 kVA and above use primary and secondary coils of identical axial length. This characteristic will negate short circuit forces that are axial, further enhancing transformer life expectancy.
Building, are of strip wound.

Out of Package Height (in) 57.840
Out of Package Width (in) 45.500
Out of Package Length/Depth (in) 41.490
Out of Package Weight (lbs) 2580.000