114233.00 2HP 1440RPM 56H IP22 220V 1PH 50 HZ CONTINUOUS 40C 1.15SF RESILIENT C6K14DR13D

BRAND: Leeson | MODEL: 114233.00 | CONDITION: NEW | SKU: 2525820
114233.00 2HP 1440RPM 56H IP22 220V 1PH 50 HZ CONTINUOUS 40C 1.15SF RESILIENT C6K14DR13D

Image for Illustration purposes only,
Actual product may vary
$519.76
FREE SHIPPING
Returnable: see conditions
Shipping from?: see locations Typically ships in 1 day
Weight: 49.00 lbs UOM: EA
100% SAFE SHOPPING
PAYMENT METHOD
 
 

Additional Description

Technical Specifications

hz 50
voltage 220
phase 1
hp 2
rpm 1500
enclosure DP

Documents

Description

 Engineering Data
Volts 220 Volts Volts  
F.L. Amps 9.6 F.L. Amps F.L. Amps
S. F Amps 10.5 S. F Amps S. F Amps

RPM 1500 Hertz 50    
HP 2 Duty CONTINUOUS TYPE KD
KW 1.50        
Frame 56H Serv. Factor 1.15 Phase 1
Max Amb 40 Design NO DESIGN CODE Code H
Insul Class F Protection NOT Therm.Prot.
Eff 100% 78 Eff 75% PF 92
UL Yes CSA Yes Bearing OPE 6203
CC Number - CE Yes Bearing PE 6203
Load Type Inverter Type Speed Range NONE

Motor Wt. 52 LB Enclosure DP Lubrication POLYREX EM
Nameplate 080671 Mounting RESILIENT BASE Rotation SELECTIVE CCW
Assembly Shaft Dia. 5/8 IN Ext. Diag. 005413.01
Cust Part No Outline 028949-800B Ext. Diag2
Packaging B Winding K634287
Carton Label Leeson Gen Purpose     GROUP:
Iris Paint VERIFY Test Card 01

Form Factor   RMS Amps   Const Torque Speed Range  
Torque   Peak      
AB Code   Peak@DegC      
Resistance          
Connection          

Rework Status   Rework TYPE      

Hazardous Loc NONE  Brake Motors  
Explosion Proof   Temp Op Code FORCE
Class GROUP: VDC
Class GROUP: ADC
        Brake Coil OHMs @25 C
Performance
Torque UOM Inertia (WK²) .16 LB-FT^2  
Torque 17(Break Down) 16.9(Pull Up) 20.8(Locked Rotor)
CURRENT (amps) 0(Break Down) 0(Pull Up) 57(Locked Rotor)
Efficiency (%) 78(75% Load) 72.3(50% Load) 56.6(25% Load)
PowerFactor 86.8(75% Load) 74.9(50% Load) 55.1(25% Load)
Speed Torque Curve @ 50 Hz, 220 Volts
Curve Point Amps Amps(%) Torque Torque(%) RPM KW PF HP
BD - - 17.0 0.0 0.0 - - 2.0
LR 57.0 - 20.8 0.0 0.0 - - 2.0
PU - - 16.9 0.0 0.0 - - 2.0
SOURCE: CALCULATED GROUP: 4
Load Curve Data @50 Hz, 220 Volts, 2 Horsepower
Load Amps KW RPM Torque EFF PF Rise By Resis Frame Rise
0.0 5.0 0.334 1498 0.0 0.0 30.4 0.0 -
0.25 5.61 0.68 1465 1.85 56.6 55.1 0.0 -
0.5 6.4 1.054 1450 3.7 72.3 74.9 0.0 -
0.75 7.6 1.452 1436 5.55 78.0 86.8 0.0 -
1.0 9.34 1.89 1419 7.4 78.9 92.0 0.0 -
1.25 11.06 2.268 1400 9.25 81.1 93.2 0.0 -
1.5 13.32 2.768 1380 11.1 78.6 94.5 0.0 -
SOURCE: CALCULATED GROUP: 4