- Catalog number: MO325-16
- SKU: 6151687
- Price: ***$298.13*** Each
- Shipping: ***FREE SHIPPING***  ON ORDERS OVER $100
- Typically Ships in: 1 day
- Brand: [ABB](https://www.mrosupply.com/brands/abb/)
- Category: 
    - [Manual Motor Starters](htts://www.mrosupply.com/electrical/starters-and-contactors/manual-motor-starters/)
    - [Starters and Contactors](htts://www.mrosupply.com/electrical/starters-and-contactors/)
    - [Electrical](htts://www.mrosupply.com/electrical/)
- Unit of measure: each
- Returns: Yes


## Product images:
- https://static.mrosupply.com/images/noimage.webp


## Product attributes;

  
- Actuator type: Rotary Handle
  

  
- Ambient air temperature: Around the Enclosure 0 ... +40 C Operation -25 ... +50 C Storage -50 ... +80 C
  

  
- Ambient air temperature compensation: No
  

  
- Ampere rating UL/CSA: 16 A
  

  
- CB certificate: 1SAA918000-2002
  

  
- CCC certificate: 1SAA918000-3806
  

  
- Connecting capacity main circuit UL/CSA: Flexible 1/2x 14-8 AWG Stranded 1/2x 14-8 AWG
  

  
- Contact position indication: ON / OFF
  

  
- Conventional free-air thermal current (Ith): Main Circuit 16 A
  

  
- cUL certificate: cUL_E137861
  

  
- cULus certificate: E137861
  

  
- Data sheet, technical information: 2CDC130002C0206
  

  
- Declaration of conformity - CE: 1SAD938506-0037
  

  
- Degree of protection: IP20
  

  
- DNV certificate: 1SAA918000-0305
  

  
- eClass: 7.0 27370401
  

  
- Electrical durability: 50000 cycle
  

  
- ETIM 4: EC000074 - Motor protective circuit-breaker
  

  
- ETIM 5: EC000074 - Motor protective circuit-breaker
  

  
- ETIM 6: EC000074 - Motor protection circuit-breaker
  

  
- GL certificate: 1SAA918000-0403
  

  
- GOST certificate: 1SAA918000-2703
  

  
- LR certificate: 1SAA918000-0503
  

  
- Max operating altitude permissible: 2000 m
  

  
- Maximum operating voltage UL/CSA: Main Circuit 600 V AC
  

  
- Mechanical durability: 100000 cycle
  

  
- Mounting position: Position 1 to 6
  

  
- Number of poles: 3
  

  
- Object classification code: F
  

  
- Pollution degree: 3
  

  
- Power loss: at Rated Operating Conditions per Pole 1.7 W
  

  
- Rated frequency: Main Circuit 50 Hz Main Circuit 60 Hz
  

  
- Rated impulse withstand voltage (U imp): Main Circuit 6 kV
  

  
- Rated instantaneous short-circuit current setting (Ii): 240 A
  

  
- Rated insulation voltage (Ui): 690 V
  

  
- Rated operational current (Ie): 16 A
  

  
- Rated operational current AC-3 (Ie): 16 A
  

  
- Rated operational voltage: Main Circuit 690 V AC Main Circuit 440 V DC
  

  
- Rated service short-circuit breaking capacity (Ics): (230 V AC) 100 kA (400 V AC) 60 kA (440 V AC) 40 kA (500 V AC) 25 kA (690 V AC) 4 kA
  

  
- Rated ultimate short-circuit breaking capacity (Icu): (230 V AC) 100 kA (400 V AC) 60 kA (440 V AC) 40 kA (500 V AC) 25 kA (690 V AC) 4 kA
  

  
- Recommended screw driver: M3.5 Pozidriv 2
  

  
- Resistance to shock acc. to IEC 60068-2-27: 11 ms Pulse 15g
  

  
- Resistance to vibrations acc. to IEC 60068-2-6: 5g / 10 ... 150 Hz
  

  
- RINA certificate: 1SAA918000-0803
  

  
- RMRS certificate: 1SAA918000-0703
  

  
- RoHS information: 1SAA918001-4401
  

  
- RoHS status: Following EU Directive 2002/95/EC August 18, 2005 and amendment
  

  
- Standards: IEC/EN 60947-1 IEC/EN 60947-2 IEC/EN 60947-4-1 UL 508 CSA 22.2 No. 14
  

  
- Tightening torque: Main Circuit 1.4 Nm
  

  
- Tightening torque UL/CSA: Main Circuit 14 inlb
  

  
- UL certificate: UL_E137861
  

  
- Wire stripping length: Main Circuit 10 mm
  
## Product documents / software:

- [ABB Low Voltage Products MMS](https://documents.mrosupply.com/product_documents/61/51/6151090/Download_hVQfKH4.aspx)
- [B01_Electrical installation solutions for buildings_part B_01_MCBs_[EN]_(PDF)](https://documents.mrosupply.com/product_documents/61/51/6151687/Download_sFHQfTE.aspx)
- [Certifications and approvals overview - Manual Motor Starters](https://documents.mrosupply.com/product_documents/61/51/6151687/Download_bAQmhzP.aspx)
- [Coordinated protections of motor Starters](https://documents.mrosupply.com/product_documents/61/51/6151687/Download_Ou6Mv3E.aspx)
- [Day by DIN - technical journal - 1/13](https://documents.mrosupply.com/product_documents/61/51/6151687/Download_EOkkTK8.aspx)
- [Installation instruction - Short circuit signal contact CK-11 for MS325 / MO325](https://documents.mrosupply.com/product_documents/61/51/6151687/Download_bUJKKWc.aspx)
- [Lifecycle Phase Status Plan 2016-03](https://documents.mrosupply.com/product_documents/61/51/6151276/Download_stlqxtr.aspx)
- [Lifecycle Phase Status Plan 2016-07](https://documents.mrosupply.com/product_documents/61/51/6151049/Download_gx0cQDe.aspx)
- [Lifecycle Phase Status Plan 2017-09](https://documents.mrosupply.com/product_documents/61/51/6151017/Download_6HpvpIc.aspx)
- [Lifecycle Phase Status Plan 2018-01](https://documents.mrosupply.com/product_documents/61/51/6151017/Download_Tgjo2Xj.aspx)
- [Lifecycle Phase Status Plan 2018-07](https://documents.mrosupply.com/product_documents/61/51/6151089/Download_M91r4qF.aspx)
- [Lifecycle Phase Status Plan 2019-06](https://documents.mrosupply.com/product_documents/61/51/6151017/Download_HpDa8uk.aspx)
- [Lifecycle Phase Status Plan 2020-02](https://documents.mrosupply.com/product_documents/61/51/6151017/Download_IFIW3o2.aspx)
- [Lifecycle Phase Status Plan 2020-07](https://documents.mrosupply.com/product_documents/61/51/6151017/Download_qzTuxQS.aspx)
- [Lifecycle Phase Status Plan 2021-01](https://documents.mrosupply.com/product_documents/61/51/6151017/Download_4dmIFQH.aspx)
- [Lifecycle Phase Status Plan 2022-01](https://documents.mrosupply.com/product_documents/61/51/6151017/Download_QM4rHyT.aspx)
- [Lifecycle Phase Status Plan 2022-07](https://documents.mrosupply.com/product_documents/61/51/6151017/Download_MZQRPrb.aspx)
- [Lifecycle Phase Status Plan 2023-01 - PDF](https://documents.mrosupply.com/product_documents/61/51/6151017/Download_uhLeHaO.aspx)
- [Lifecycle Phase Status Plan 2023-08 - PDF](https://documents.mrosupply.com/product_documents/61/51/6151017/Download_s7ROM5G.aspx)
- [Line card - Low- and medium-voltage products and systems for wind applications](https://documents.mrosupply.com/product_documents/61/51/6151687/Download_jB5S3lZ.aspx)
- [MO325 Manual Motor Starter magnetic only - Data sheet - PDF](https://documents.mrosupply.com/product_documents/61/51/6151687/Download_MHzh4MD.aspx)
- [System pro M compact - Circuit Protection on Din Rail - US Version](https://documents.mrosupply.com/product_documents/61/51/6151057/Download_hNDyv8S.aspx)
- [Technical Application Papers No.7 - Three-phase asynchronous motors](https://documents.mrosupply.com/product_documents/61/51/6151025/Download_MVC7a9T.aspx)