# IFM SM2001 Magnetic-inductive flow meter - MROSupply.com

***IFM SM2001 Magnetic-inductive flow meter***



## Product details:

- Catalog number: SM2001
- SKU: 96944327
- Price: ***$1,391.94*** Each
- Shipping: ***FREE SHIPPING***  ON ORDERS OVER $100
- Brand: [IFM](https://www.mrosupply.com/brands/ifm/)
- Category: 
    - [Automation](htts://www.mrosupply.com/automation/)
- Unit of measure: each
- Returns: Yes


## Product images:
- https://assets.mrosupply.com/images/noimage.webp


## Product attributes;

  
- Accuracy (In The Measuring Range): ± (0, 8 % MW + 0, 5 % MEW)
  

  
- Accuracy [K]: ± 1 (77 °F; Q > 4 gpm)
  

  
- Ambient Temperature (°F): 14...140
  

  
- Ambient temperature [°F]: 14...140
  

  
- Analog Current Output (Ma): 4...20
  

  
- Analog current output [mA]: 4...20; (scalable)
  

  
- Analog End Point (°F): 32...176
  

  
- Analog end point [°F]: 32...176
  

  
- Analog Start Point (°F): -4...140
  

  
- Analog start point [°F]: -4...140
  

  
- Analog Voltage Output (V): 0...10
  

  
- Analog voltage output [V]: 0...10; (scalable)
  

  
- Communication Interface: IO-Link
  

  
- Connector: 1 x M12; coding: A; Contacts: gold-plated
  

  
- Current Consumption (Ma): < 150
  

  
- Current consumption [mA]: < 150
  

  
- Damping Process Value dAP (S): 0...5
  

  
- Damping process value dAP [s]: 0...5
  

  
- Delay Time Programmable Ds, Dr (S): 0...50
  

  
- Delay time programmable dS, dr [s]: 0...50
  

  
- Dimensions (mm): 200 x 103 x 117
  

  
- Dimensions [mm]: 200 x 103 x 117
  

  
- Display Range (°F): -40...212
  

  
- Display range [°F]: -40...212
  

  
- Display Unit: 6 x LED, green (gpm, gph, gal, °F, 10³, 1000 x 10³)
  

  
- Dp: Pressure Loss
  

  
- Dynamic Response T05 / T09 (S): T09 = 3 (Q > 4 gpm)
  

  
- Dynamic response T05 / T09 [s]: T09 = 3 (Q > 4 gpm)
  

  
- Electrical Design: PNP / NPN
  

  
- File Number UL: E174189
  

  
- Frequency of The Output (Hz): 0.1...10000
  

  
- Frequency of the output [Hz]: 0.1...10000
  

  
- Housing: Rectangular
  

  
- In Steps of: 0.02 gal
  

  
- In steps of [°F]: 0.5
  

  
- Inlet Pipe Length: 3 x DN
  

  
- Inputs: Counter Reset
  

  
- Installation: Connection to pipe by means of an adapter
  

  
- IO-Link Revision: 1.1
  

  
- Max. load [Ω]: 500
  

  
- Max. voltage drop switching output DC [V]: 2
  

  
- Maximum Load (Ω): 500
  

  
- Maximum Voltage Drop Switching Output DC (V): 2
  

  
- Measured Values: alphanumeric display, 4-digit
  

  
- Measuring Dynamics: 1:120
  

  
- Measuring Principle: Magnetic-inductive
  

  
- Measuring Range (°F): -4...176
  

  
- Measuring range [°F]: -4...176
  

  
- Media: Conductive Liquids; Water; Water-based Media
  

  
- Medium Temperature (°F): 14...194
  

  
- Medium temperature [°F]: 14...194
  

  
- Min. load resistance [Ω]: 2000
  

  
- Min. process cycle time [ms]: 5
  

  
- Minimum Load Resistance (Ω): 2000
  

  
- Minimum Process Cycle Time (Ms): 5
  

  
- MTTF (Years): 85
  

  
- MTTF [years]: 85
  

  
- Number of Analog Outputs: 1
  

  
- Number of Digital Outputs: 2
  

  
- Number of inputs and outputs: Number of digital outputs: 2; Number of analog outputs: 1
  

  
- Operating Voltage (V): 18...32 DC
  

  
- Operating voltage [V]: 18...32 DC; (to SELV/PELV)
  

  
- Outlet Pipe Length: 1 x DN
  

  
- Output Function: Normally Open / Closed
  

  
- Overload Protection: Yes
  

  
- Permanent Current Rating of Switching Output DC (Ma): 250
  

  
- Permanent current rating of switching output DC [mA]: 250; (per output)
  

  
- Power-on Delay Time (S): 5
  

  
- Power-on delay time [s]: 5
  

  
- Process Connection: threaded connection G 2 external thread DN50 flat seal
  

  
- Process data analog: 3
  

  
- Process data binary: 2
  

  
- Programming: alphanumeric display, 4-digit
  

  
- Protection: IP 65; IP 67
  

  
- Protection Class: III
  

  
- Pulse Length (S): 0, 008...2
  

  
- Pulse length [s]: 0, 008...2
  

  
- Pulse Output: Flow Rate Meter
  

  
- Pulse Value: 0.02...160 E06 gal
  

  
- Q: Volumetric Flow Quantity
  

  
- Repeatability: ± 0, 2% MEW
  

  
- Required master port class: A
  

  
- Reset Point Rp (°F): -3...175
  

  
- Reset point rP [°F]: -3...175
  

  
- Resolution (°F): 0.5
  

  
- Resolution [°F]: 0.5
  

  
- Response Time (S): 0.35
  

  
- Response time [s]: 0.35; (dAP = 0)
  

  
- Reverse Polarity Protection: Yes
  

  
- SDCI Standard: IEC 61131-9 CDV
  

  
- Set Point SP (°F): -2...176
  

  
- Set point SP [°F]: -2...176
  

  
- Short-circuit Protection: Yes
  

  
- SIO mode: Yes
  

  
- Special feature: Gold-plated contacts
  

  
- Storage Temperature (°F): -13...176
  

  
- Storage temperature [°F]: -13...176
  

  
- Switching Status: 2 x LED, yellow
  

  
- Temperature Drift: ± 0, 0185 °F / K
  

  
- Total Number of Outputs: 2
  

  
- Transmission type: COM2 (38, 4 kBaud)
  

  
- Type of Short-circuit Protection: Yes (Non-latching)
  
## Product documents / software:

- [Product Data Sheet](https://docs.mrosupply.com/product_documents/96/94/96944327/ifm2FSM2001-01_EN-GB_AkXmLNR.pdf)