# IFM SMF950 SMGX2KGFFRKG/UST Magnetic-inductive flow meter - MROSupply.com

***IFM SMF950 SMGX2KGFFRKG/UST Magnetic-inductive flow meter***



## Product details:

- Catalog number: SMF950
- SKU: 96944393
- Price: ***$4,626.16*** Each
- Shipping: ***FREE SHIPPING***  ON ORDERS OVER $100
- Brand: [IFM](https://www.mrosupply.com/brands/ifm/)
- Category: 
    - [Automation](htts://www.mrosupply.com/automation/)
- Unit of measure: each
- Returns: Yes


## Product images:
- https://assets.mrosupply.com/images/noimage.webp


## Product attributes;

  
- Accuracy (K): ± 1 (v > 0, 5 m / s)
  

  
- Accuracy [K]: ± 1 (v > 0, 5 m/s)
  

  
- Analog Current Output (Ma): 4...20
  

  
- Analog current output [mA]: 4...20; (skalierbar)
  

  
- Analog End Point (µS/Cm): 20000...100000
  

  
- Analog end point [µS/cm]: 20000...100000
  

  
- Analog Start Point (µS/Cm): 0...80000
  

  
- Analog start point [µS/cm]: 0...80000
  

  
- Binary Switching Information: 8
  

  
- BLOB: Binary Large Object Transfer
  

  
- Communication Interface: IO-Link
  

  
- Conductivity: 32
  

  
- Connector: 1 x M12; coding: A; Contacts: gold-plated
  

  
- Current Consumption (Ma): 250
  

  
- Current consumption [mA]: 250; (24 V)
  

  
- Damping Process Value dAP (S): 0...5
  

  
- Damping process value dAP [s]: 0...5
  

  
- Diagnostic functions: Direction of flow detection; liquid detection
  

  
- Dimensions (mm): Ø 255 / L = 200
  

  
- Dimensions [mm]: Ø 255 / L = 200
  

  
- DIN IEC 68-2-27: 20 g (18ms)
  

  
- DIN IEC 68-2-6: 5 g (10...2000Hz)
  

  
- Electrical Design: PNP / NPN
  

  
- Factory setting: M³/h; °C; μS/cm
  

  
- File Number UL: E174189
  

  
- Flow: 32
  

  
- Housing: Tubular
  

  
- In The Range of 100...20000 µS/Cm: ±10% MW
  

  
- In The Range of 20000...100000 µS/Cm: ±20% MW
  

  
- Inlet Pipe Length: 5 x DN
  

  
- IO-Link Revision: 1.1.3
  

  
- Materials (Wetted Parts): Pipe section: PFA; electrodes: stainless steel (1.4435 / 316L)
  

  
- Max. load [Ω]: 500
  

  
- Max. voltage drop switching output DC [V]: 2
  

  
- Maximum Load (Ω): 500
  

  
- Maximum Voltage Drop Switching Output DC (V): 2
  

  
- Measuring Principle: Magnetic-inductive
  

  
- Measuring Range (µS/Cm): 100...100000
  

  
- Measuring range [µS/cm]: 100...100000
  

  
- Media: Conductive Liquids; Water; Water-based Media
  

  
- Medium Temperature (°C): -20...150
  

  
- Medium temperature [°C]: -20...150
  

  
- Min. process cycle time [ms]: 1.9
  

  
- Minimum Process Cycle Time (Ms): 1.9
  

  
- MTTF (Years): 83
  

  
- MTTF [years]: 83
  

  
- Nominal Diameter: DN150 (6“)
  

  
- Number of Analog Outputs: 1
  

  
- Number of Digital Outputs: 2
  

  
- Operating Status: LED ring, three-color
  

  
- Operating Voltage (V): 18...32 DC
  

  
- Operating voltage [V]: 18...32 DC
  

  
- Outlet Pipe Length: 2 x DN
  

  
- Overload Protection: Yes
  

  
- Pack quantity: 1 pcs.
  

  
- Permanent Current Rating of Switching Output DC (Ma): 100
  

  
- Permanent current rating of switching output DC [mA]: 100
  

  
- Power-on Delay Time (S): < 5
  

  
- Power-on delay time [s]: < 5
  

  
- Process Connection: Ifm-specific Device Flange
  

  
- Process data analog: 6
  

  
- Process data binary: 8
  

  
- Protection: IP 67; IP 69
  

  
- Protection Class: III
  

  
- Pulse Length (S): 0.00005...2
  

  
- Pulse length [s]: 0.00005...2
  

  
- Pulse Output: Flow Rate Meter
  

  
- Pulse Value: 0.017...99999000 I
  

  
- Repeatability: ± 5% MW
  

  
- Repeatability [K]: ± 0, 5 (v > 0, 5 m/s)
  

  
- Required master port class: A
  

  
- Resolution of Analog Output: 0.38 µA
  

  
- Response Time (S): < 2
  

  
- Response time [s]: < 0.3
  

  
- Reverse Polarity Protection: Yes
  

  
- SDCI Standard: IEC 61131-9
  

  
- Short-circuit Protection: Yes
  

  
- SIO mode: Yes
  

  
- Special feature: Gold-plated contacts
  

  
- Standard: ± (0, 5 % MW + 1, 5 mm / s)
  

  
- Status: 4
  

  
- Surface Characteristics Ra/Rz of The Wetted Parts: Ra < 0.4 μm
  

  
- Switching Frequency DC (Hz): 0...10000
  

  
- Switching frequency DC [Hz]: 0...10000
  

  
- Temperature: 32
  

  
- Total Number of Inputs and Outputs: 2
  

  
- Total Number of Outputs: 2
  

  
- Totalizer: 32
  

  
- Transmission type: COM3 (230, 4 kBaud)
  

  
- Type of Short-circuit Protection: Yes (Non-latching)
  

  
- with Optional Factory Calibration (Availability Is Being Planned): ± (0, 2 % MW + 2 mm / s)
  
## Product documents / software:

- [Product Data Sheet](https://docs.mrosupply.com/product_documents/96/94/96944393/ifm-22FSMF950-00_EN-GB_TxmqTts.pdf)