10437585

Image for Illustration purposes only. Actual product may vary

View in markdown

Rexnord AMN85207 10437585 2 7/16 TAKEUP ROLLER BEARING

MODEL 10437585

BRAND

SKU

501595

WEIGHT

31.000 lb

UOM

each

UPC

698210201623

Contact supplier for technical support on: 800-626-2120

$4,189.89 Each

Prices are subject to change

FREE SHIPPING ON ORDERS OVER $100

Select Quantity

GET A QUOTE

Returnable: See conditions

Ability to Relubricate

Yes

Adjustment slot width (in)

3.08

Auxiliary cap kit

A8207

Auxiliary seals

2 open caps cast iron

Auxiliary Seals

2 OPEN CAPS CAST IRON

Bearing Brand

REX ROLLER BEARING

Bore size (in)

2.4375 in

Bore Size (in)

2.4375 in

Bottom Channel Outside Width (in)

3.94

Bottom Housing Length (in)

8.56

Bottom Take Up Slot to Centerline of Bearing (in)

2.63

Cage Material

Engineered Polymer

Clearance

C3 STANDARD

Fixed vs. Expansion

Fixed

Grease Fitting Thread Size

1/8 NPT

Height

6.25

Housing coating

Powder coated

Housing Coating

POWDER COATED

Housing Color

Black

Housing construction

Solid

Housing Construction

Solid

Housing material

Cast iron

Housing Material

Cast Iron

Housing style

Take-Up Block

Housing Style

Take-Up Block

Housing Top Width (in)

2.63

Housing type

Take Up, Top Angle

Housing Type

Take Up, Top Angle

Inner Ring Outside Diameter (in)

2.901

Insert

5207U

Length

11.25

Length Through Bore (in)

4.37

Locking collar outside diameter (in)

3.55

Locking device kit

SC8 QTY 2

Locking Device Kit

SC8 QTY 2

Locking Type

Double Set Collar

Lubrication type

EXXON RONEX MP STD

Lubrication Type

EXXON RONEX MP STD

Maximum Speed (RPM)

2000 rpm

Maximum Temperature (C)

107

Maximum Temperature (F)

225

Microlock kit

ML8

Misalignment Capability

±2.0° Misalignment - Dynamic

Misalignment Type

Dynamic

Net Weight

31.00

Overall Length (in)

8.56

Overall width

3.94

Primary seal

Buna spring loaded lip seal

Primary Seal

BUNA SPRING LOADED LIP SEAL

Radial Dynamic Load Capacity (lb)

43240 lb

Radial Static Load Capacity (lb)

53500 lb

Retainer material

Engineered Polymer

Retainer Material

Engineered Polymer

Rolling element

Spherical Roller

Seal kit

MS8

Seal type

Heavy Contact Seal

Size code

8

Size Code

8

Slot Depth (in)

1.47

Slot Length (in)

7

Slot Width (in)

1

Top Housing Length (in)

8.56

Unit of dimension

in

Unit of Dimension

IN

Vibration frequency fundamental train

0.0072 cps

Vibration Frequency Fundamental Train

0.0072 cps

Vibration frequency inner ring defect

0.1791 cps

Vibration Frequency Inner Ring Defect

0.1791 cps

Vibration frequency outer ring defect

0.1376 cps

Vibration Frequency Outer Ring Defect

0.1376 cps

Vibration frequency roller spin

0.0607 cps

Vibration Frequency Roller Spin

0.0607 cps

Volume

1.922

Volume unit

GLL

Volume Unit

GLL

Weight unit

LB

Width

6.31

2 7/16" Mounted Spherical Roller Bearing, Fixed Top Angle Protected Screw Take-up Block, Double Setscrew Locking Collar, Spring Loaded Heavy Contact Seal, Two Open Auxiliary Caps

How do I read a Rexnord (Rex) spherical roller bearing part number like ZA2115? This product

Read a Rex number as seal, housing, series, bore. In ZA2115, Z is the clearance seal, A a fixed 2-bolt pillow block, 2 the 2000 series and 115 the bore, 1 15/16 in (first digit inches, last two sixteenths). Other seal letters are K light contact, M spring loaded heavy contact and G triple lip. Housing codes include B 4-bolt flange, BR round flange cartridge, MC cartridge, EP Type E pillow block, EF Type E flange, F flange and T take-up. A trailing F means a 4-bolt pillow block base (ZA2307F), MM a metric bore (ZEP2045MM) and Y a redesigned shaft size that does not interchange with the older unit.

What is the difference between the Rex 2000, 3000, 5000, 6000 and 9000 series? This product

The series digit sets how the bearing locks to the shaft, and with it the duty level. 2000 uses a single setscrew collar (normal duty, simplest and cheapest), 3000 an eccentric Twist Lock collar (medium duty, extra holding power), 5000 a double setscrew collar (heavy duty), 6000 the Shurlok tapered adapter (heavy duty, full bore contact, easily removed) and 9000 a tapered adapter sleeve (extra heavy duty). Bores: ZA2000 covers 3/4 to 4 in, ZA5000 1 7/16 to 4 in and ZA6000 1 7/16 to 3 15/16 in. On take-up blocks a frame size code comes before the series digit, so ZT62115 is a 2000 series take-up, not 6000.

Which Rexnord roller bearings are fixed and which are expansion? This product

An S after the housing letters marks an expansion unit (Rexnord calls it floating), where the insert can move axially in the housing to absorb shaft growth: ZAS2115 is the expansion version of the fixed ZA2115, and the same applies to MPS, ZPS, ZBS, ZFS and ZAFS codes. Rex 2000 series units give a total of 3/8 in of expansion travel. Usual practice is one fixed bearing per shaft to locate it and expansion units at the other positions. Auxiliary cap kits are specific to fixed or expansion units: AS10307 is an open cap kit for 3 7/16 in expansion units, size code 10, in the 2000, 3000, 5000 and 9000 series.

What seal options do Rex mounted roller bearings come with? This product

Rex spherical roller bearings come with four seal types, and the first letter of the part number (after any A or B end cap prefix) tells you which: Z is the all metal clearance seal (ZA2115), K a single lip light contact seal (KA2307), M a spring loaded heavy contact seal (MA2107) and G a triple lip seal (GBR2315G). A V suffix on an M seal unit means Viton seal material for higher temperatures (AMA2207V). Rexnord states the seals are field interchangeable, so a unit can be changed from clearance to contact seals without replacing it. All Rex units allow a total of 4 degrees of misalignment, and auxiliary end caps can be added for extra protection.

How do I order a Rexnord roller bearing with end caps, or a replacement insert? This product

Factory end caps are coded into the part number. A prefix A means two open auxiliary caps (AMA2107) and B one open cap on the housing side and one closed cap on the cover side (BMA2108, BZEP2115), used where the shaft ends at the bearing. A single cap is a suffix instead: A one open cap (MB2115A), C a closed cap on the housing side (MEP2200C). Caps also come as kits, for example B10 is a closed cap kit for fixed units in size code 10 of the 2000, 3000, 5000 and 9000 series; 6000 series units take their own adapter cap kits. Unmounted replacement inserts carry a U suffix: 2215U is a 2 15/16 in 2000 series insert.

What are the typical load ratings for take-up bearing units? Bearing basics

Load capacity varies by unit size—for example, the UCT 205 (25mm bore) carries a dynamic load rating of 14 kN and static load rating of 7.85 kN. Larger bores provide proportionally higher load capacity; choose the unit based on your belt tension and application demands.

What are take-up bearing units used for? Bearing basics

Take-up bearing units maintain proper tension on conveyor belts and chain drives while keeping the belt aligned. The adjustable bearing housing allows precise tension control by rotating a take-up screw, ensuring consistent power transmission and extended belt life.

What bore sizes are available in standard UCT take-up units? Bearing basics

Standard UCT take-up units range from 12mm to 75mm bore diameters, with common sizes including UCT 205 (25mm), UCT 207 (35mm), and UCT 214 (70mm). Selection depends on the shaft diameter and load requirements of your conveyor or drive system.

What lubrication and relubrication intervals should I use for take-up bearing units? Bearing basics

Take-up units arrive pre-lubricated and ready for installation; relubrication intervals depend on bore size, operating speed, and temperature. In standard conditions, relubrication is typically needed at 500–2,000-hour intervals; reduce intervals by 50% in contaminated, high-temperature, or high-moisture environments.

What are the maximum speed limits for take-up bearing units? Bearing basics

Speed ratings decrease with bore size. Smaller take-up units are rated for higher speeds with proper lubrication, while larger units are limited to lower speeds due to increased radial mass. Consult the manufacturer's technical datasheet for your specific unit size to confirm maximum operating speed for your application.

How do take-up bearings maintain proper tension in conveyor systems? Bearing basics

Take-up bearings feature a sliding slot or threaded adjustment mechanism in their cast iron or pressed steel housing that allows axial movement of the bearing assembly. By repositioning the bearing along the frame using a screw or similar device, operators can adjust the distance between pulleys to increase or decrease belt tension without extensive disassembly of the conveyor system.

What types of take-up bearings are available and how do they differ? Bearing basics

Common types include frame-mounted take-ups (mounted within frame structures for conveyor systems), center-pull units (featuring a pull-style design for easy adjustment in space-constrained applications), and top-angle units (angled designs for addressing misalignment issues). Each type is optimized for different mounting configurations, load directions, and installation environments.

What is a take-up bearing and what is its primary purpose? Bearing basics

A take-up bearing is a specialized mounted bearing unit designed to maintain proper tension in belts, chains, and other flexible drive elements while supporting rotating shafts. The bearing combines a standard ball or roller bearing insert with an adjustable housing that permits controlled movement along a linear path, enabling engineers to adjust shaft positioning and maintain optimal tension as components stretch or wear over time.

What specifications should I consider when selecting a take-up bearing? Bearing basics

Key specifications include bore diameter (shaft size), load capacity (static and dynamic ratings), speed rating (RPM limit), housing material (cast iron or pressed steel), and adjustment type (screw, eccentric collar, or adapter sleeve). Typical bore sizes range from 12mm to larger diameters, with load capacities and speed ratings varying based on the bearing type and housing design; pre-lubricated units often use premium greases like Chevron SRI-2 for extended intervals between relubrication.

What are common applications for take-up bearings? Bearing basics

Take-up bearings are essential in conveyor systems, agricultural machinery, material handling equipment, and industrial drive systems across food processing, manufacturing, mining, construction, and quarrying industries. They support both radial and axial loads while maintaining proper belt or chain tension to prevent slippage and reduce vibration and wear.

How do I select the right bearing size and load rating for my application? Bearing basics

Match the bore diameter to your shaft size, then verify the dynamic load rating (C) exceeds your expected radial load. For radial loads, use C ≥ 3× your maximum load as a conservative starting point. Check speed rating against your RPM—pillow blocks typically handle 3,000–4,000 rpm while flange units can push 5,000+ rpm depending on bolt strength and bearing series.

What lubrication schedule should I follow? Bearing basics

Use the bearing manufacturer's recommended grease grade and relubricate at intervals matched to your speed and load—heavy-duty applications may need monthly service, while light-duty runs can extend to 6–12 months. Over-greasing creates drag and heat; under-greasing causes metal-to-metal contact. Wipe off excess grease to prevent contamination.

What's the difference between 2-bolt and 4-bolt flange mounts? Bearing basics

2-bolt (diamond) flanges fit tight spaces and light-to-moderate loads. Switch to 4-bolt (square) flanges for cantilevered (overhung) loads, torque reversal, or shafts over 50mm—the extra bolts distribute load more evenly and resist side thrust better.

How should I install and align a mounted roller bearing? Bearing basics

Align the bearing housing parallel to the shaft using a straightedge or dial indicator—misalignment is a leading cause of premature wear. Tighten mounting bolts in a cross pattern to seat the housing evenly. Use a soft mallet to tap the bearing unit into place; never force it. Check alignment after installation.

What's the difference between pillow block and flange mounted bearings? Bearing basics

Pillow blocks mount parallel to the shaft (shaft runs horizontally along the base), while flange blocks mount perpendicular to the shaft (shaft extends out from the face). Choose pillow blocks for shafts that are level with your mounting surface; choose flange blocks when the shaft is perpendicular to your mount point.

What temperature should a mounted bearing run at? Bearing basics

Monitor housing surface temperature (the standard MRO measurement point): 40–65°C is normal, 70–75°C warrants investigation of misalignment or over-greasing, and 80°C requires immediate shutdown. The inner race runs 15–30°C hotter than the housing surface, so an 80°C housing reading means lubricant degradation is accelerating and the bearing requires emergency diagnosis.

How often should I grease a mounted bearing? Bearing basics

Use the formula (OD in mm) × (Width in mm) × 0.005 = grams for periodic relubrication of the bearing element only; initial housing cavity fill is separate and should be 30–50% of free volume. Over-greasing damages seals and generates excess heat—stick to the calculated quantity and recommended relubrication schedule.

How do I install a mounted bearing correctly? Bearing basics

Verify your shaft diameter is within the bearing bore tolerance (consult the NSK or SKF datasheet), then secure the bearing to the mounting surface using the specified bolt torque and engage the locking collar or set-screw on the shaft to prevent axial slip. Hand-rotate the shaft through several complete turns with a dial indicator, laser alignment tool, or feeler gauge to confirm smooth operation and proper shaft runout within spec.

What are the main types of mounted bearings? Bearing basics

Mounted bearings come in four main forms: pillow blocks (flat-base, shaft parallel to mounting surface), flange mounts (perpendicular shaft, available in 2-bolt and 4-bolt variants with different radial ratings), hanger bearings (overhead support for long horizontal shafts), and take-up frames (adjustable center-distance units for belt or chain drive tensioning). Select based on your shaft orientation, load direction, and space constraints.

When should I replace a mounted bearing? Bearing basics

Replace based on condition: vibration signature analysis or ultrasonic emission (detected with a hand-held meter) indicates wear hours or days before audible noise appears, and is the actionable MRO signal. Other replacement triggers include continuous operation above 80°C housing temperature, visible grease leakage, or reaching the manufacturer's service interval for your duty cycle. Scheduled relubrication and temperature monitoring extend service life significantly — replacement is a last resort, not preventive maintenance.

How do I choose the right type of bearing for my application? Bearing basics

Start with the load and how it’s applied. You need to know if you’re dealing with radial loads, axial loads, or a mix of both. Then look at speed, operating environment, and space constraints. For example, ball bearings are great for high speed and lighter loads, while roller bearings handle heavier loads but usually at lower speeds. If there’s contamination, moisture, or heat involved, you may need sealed bearings or specific materials. In most cases, the right choice comes down to matching load type, speed, and environment to the bearing design.

How should I maintain and lubricate bearings? Bearing basics

Lubrication Importance — Improper lubrication causes over 40% of bearing failures. Proper bearing lubrication prevents friction damage, dissipates heat, protects against corrosion, and acts as a barrier against contaminants (dust, moisture, debris). Lubrication Selection — Choose between grease and oil based on: - Grease: Suitable for low-to-medium speed, sealed bearings, and applications without continuous circulation. Easier to apply and retain. Common for motors, household appliances, and sealed units. - Oil Mist or Circulating Systems: Better for high-speed applications, high-temperature environments, and heavy-load machinery where heat dissipation is critical. Best Practices: 1. Map all lubrication points and create a maintenance schedule. 2. Use the correct lubricant type and viscosity grade specified by the bearing manufacturer. 3. Store lubricants in sealed, labeled containers away from moisture and contaminants. 4. Monitor bearing temperature and vibration; unusual heat or noise may indicate inadequate lubrication or bearing wear. 5. Replace bearings before reaching L10 life if contamination or lubrication failure is detected.

What are dynamic and static load ratings, and why do they matter? Bearing basics

Static Load Rating (C₀) — The maximum load a stationary or slowly rotating bearing can support without permanent deformation of its rolling elements or raceways. Defined by ISO 76 as the load producing 0.01% permanent deformation of the rolling element diameter. Static load capacity is the limiting factor when a bearing operates at very low speeds or remains stationary under heavy loads. Dynamic Load Rating (C) — The constant load a bearing can endure for a specified number of revolutions (the L10 life, at which 90% of identical bearings are expected to survive). Dynamic load rating determines how long a bearing will last under rotating or oscillating motion. ISO 281 defines the L10 calculation using the formula: L10 = (C/P)^p, where C is dynamic load rating, P is equivalent dynamic load, and p is the life exponent (3 for ball bearings, 10/3 for roller bearings). Why They Matter — Static load rating determines if a bearing can handle peak loads without permanent damage (even if not rotating). Dynamic load rating determines operational life. For high-speed applications, dynamic rating is critical. For low-speed or stationary loads, static rating may be the limiting factor. Always verify both ratings against your application's load profile.

What bearing materials are available and which should I use? Bearing basics

Standard bearing materials include: - Chrome Steel — Premium bearing steel used by SKF, NSK, Timken, and most manufacturers. Offers excellent hardness, fatigue resistance, and durability in standard industrial applications. Most common for ball and roller bearings. - Stainless Steel — Provides corrosion resistance for applications in wet, humid, or chemically corrosive environments. Used in food processing, marine, and pharmaceutical equipment. - Ceramic Hybrid Bearings — Combine steel races with ceramic rolling elements. Offer reduced friction, lower heat generation, and higher temperature capability. Used in high-speed, high-precision applications and aerospace. - Polymeric Bearings — Utilize fluoropolymer composites with embedded graphite or PTFE. Provide low friction in high-speed applications where lubrication film breakdown would be problematic. Material selection depends on operating environment (temperature, moisture, chemical exposure), speed, load, and precision requirements. Standard chrome steel bearings suit most industrial MRO applications.

How do I choose the right bearing for my application? Bearing basics

Bearing selection depends on five key factors: 1. Load Type and Direction — Determine whether your application has radial loads (perpendicular to shaft), axial loads (along the shaft), or combined loads. Deep groove ball bearings suit primarily radial loads; tapered roller bearings excel at combined loads; thrust bearings handle pure axial forces. 2. Rotational Speed — Ball bearings support higher speeds with lower friction. Roller bearings are better for medium-speed, heavy-load applications. Verify bearing speed ratings against your operating RPM. 3. Load Capacity — Select a bearing with adequate load capacity for your application. Basic dynamic load rating (C) and basic static load rating (C₀) determine how much load the bearing can safely carry. 4. Lubrication Requirements — Choose between grease and oil lubrication based on speed, temperature, and load. High-speed or high-temperature applications typically require oil circulation; lower-speed applications can use grease. 5. Precision and Rigidity — Evaluate your application's tolerance for runout deviation. High-precision applications require tighter tolerances and higher-grade bearings.

What is a bearing and what does it do? Bearing basics

A bearing is a mechanical component that enables smooth rotational or linear motion by reducing friction between moving parts. Bearings support loads and facilitate the transfer of forces between moving elements, preventing direct metal-to-metal contact that would cause wear and heat buildup. Rolling element bearings contain balls or rollers that rotate within races (raceways) to minimize friction. Common types include ball bearings (used for moderate loads and high speeds), roller bearings (used for heavy loads at medium speeds), and angular contact bearings (designed for combined radial and axial loads). Bearings are essential in industrial equipment including motors, pumps, compressors, gearboxes, turbines, and conveyor systems.

What is bearing life (L10) and how does it affect my equipment maintenance? Bearing basics

L10 Life Definition (ISO 281) — L10 is the basic rating life at which 90% of a large group of identical bearings are statistically expected to survive under constant load and speed. It is calculated in millions of revolutions using the formula: L10 = (C/P)^p, where C is the basic dynamic load rating, P is the equivalent dynamic bearing load, and p is the life exponent (3 for ball bearings). Converting L10 to Operating Hours — To express L10 life in hours: L10h = (L10 × 10^6) / (60 × n), where n is rotational speed in RPM. For example, a bearing with L10 = 1,000 million revolutions operating at 3,600 RPM has approximately L10h ≈ 4,630 hours. Modified Life (L10a) — Actual bearing life also depends on lubrication quality, contamination, speed, temperature, and bearing accuracy. ISO 281 defines a modified life factor (a₁ × aISO) that adjusts the theoretical L10 for these real-world conditions. High-quality lubrication and proper maintenance can extend bearing life significantly; poor lubrication or high contamination reduces it. Why It Matters for Maintenance — L10 life helps you schedule preventive maintenance, budget for bearing replacement, and select bearings adequate for your duty cycle.

When will I be charged for my order? Ordering Do you provide credit terms? Ordering Can I get a discounted price? I am a reseller / government entity. Ordering What is the return/warranty policy? Ordering Can it be shipped today? Ordering Does “Usually ships in 24 hours” mean it’s in stock? Ordering Read full FAQ All FAQs
5.0 out of 5 · 4 reviews

Mechanic

Verified · SKU 492145

Great service and fast shipping and great quality of product. Read more

Good orice

Verified · SKU 495479

This stump grinder wheel bearing is expensive and I need two each time I change them. Best price I found anywhere and free shipping here at MRO Supply Read more

Great service-fast shipping

Verified · SKU 1303956

Awesome service. I would highly recommend doing business with MRO! Price was cheapest anywhere Read more

Rexnord idler pulley

Verified · SKU 523062

Great pricing and fast shipping A +++++++++ Read more

Recently Viewed
56704

#6027403

Brand

Vikan

Model

56704

Call for pricing
313589

#6108157

Brand

Greenfield Threading

Model

313589

$20.38 Each
Free Shipping orders over $100
423124

#6170761

Brand

Schunk

Model

423124

$10,164.71 Each
Free shipping
26-9AB53

#96738066

Brand

Meltric

Model

26-9AB53

$449.11 Each
Free shipping
253333

#6173210

Brand

Schunk

Model

253333

$1,277.00 Each
Free shipping
480988

#6473716

Brand

Flowtrend

Model

480988

$38.95 Each
Free Shipping orders over $100

Return policy

Item must be unused.

Item must be in it's original package.