A26-30-32-88

Image for Illustration purposes only. Actual product may vary

ABB A26-30-32-88 Contactor | A26-30-32-88

MODEL A26-30-32-88

BRAND

ABB

SKU

6151053

UOM

each

Call for Pricing - 888-671-2883

Typically Ships in: 1 day

Returnable: Yes

BV certificate

BV_2634H07559D0

CB certificate

CB_FR_602227A

CCC certificate

CCC_2013010304615752 CCC_2004010309133982

Climatic withstand

acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II

Coil operating limits

(acc. to IEC 60947-4-1) 0.85 ... 1.1 x Uc (at 55 C) C

Connecting capacity auxiliary circuit

Flexible with Cable End 0.75 ... 2.5 mm Rigid Cable 1 ... 4 mm

Connecting capacity main circuit

Flexible with Cable End 0.75 ... 4 mm Rigid Cable 1.5 ... 6 mm

Connecting terminals (delivered in open position) main poles

M 4 (+,-) pozidriv 2 screws with cable clamp

Conventional free-air thermal current (Ith)

acc. to IEC 60947-4-1, Open Contactors q = 40 C 45 A acc. to IEC 60947-5-1, q = 40 C 16 A

CSA certificate

CSA_1033838_LR056745

cUL certificate

UL_071301E39231

Data sheet, technical information

1SBC100122C0202_Ch02

Declaration of conformity - CE

1SBD250801U1000

Degree of protection

acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20

DNV certificate

DNV-GL_TAE00000TX

EAC certificate

EAC_RU C-FR ME77 B01010

ETIM 4

EC000066 - Magnet contactor, AC-switching

ETIM 5

EC000066 - Magnet contactor, AC-switching

ETIM 6

EC000066 - Power contactor, AC switching

GL certificate

DNV-GL_TAE00000TX

GOST certificate

GOST_POCCFRME77B07175

LR certificate

LRS_9830011E4

Max electrical switching frequency

AC-1 600 cycles per hour AC-2 / AC-4 300 cycles per hour AC-3 1200 cycles per hour

Max mechanical switching frequency

3600 cycles per hour

Max operating altitude permissible

3000 m

Number of auxiliary contacts NC

2

Number of auxiliary contacts NO

3

Number of main contacts NC

0

Number of main contacts NO

3

Object classification code

Q

Rated breaking capacity AC-3 acc. to IEC 60947-4-1

8 x Ie AC-3

Rated control circuit voltage (Uc)

50 Hz 230 240 V 60 Hz 240 260 V

Rated frequency

Supply Circuit 50 Hz Supply Circuit 60 Hz

Rated impulse withstand voltage (U imp)

8 kV

Rated making capacity AC-3 acc. to IEC 60947-4-1

10 x Ie AC-3

Rated operational current AC-1 (Ie)

(690 V) 40 C 45 A (690 V) 55 C 40 A (690 V) 70 C 32 A

Rated operational current AC-15 (Ie)

(220 / 240 V) 4 A (24 / 127 V) 6 A (380 / 440 V) 3 A (500 V) 2 A (690 V) 2 A

Rated operational current DC-13 (Ie)

(125 V) 0.55 / 69 A (24 V) 6 / 144 A (250 V) 0.3 / 75 A (48 V) 2.8 / 134 A (72 V) 1 / 72 A

Rated operational voltage

Main Circuit 690 V

RINA certificate

RINA_ELE128713XG001

RMRS certificate

RMRS_0507015250

RoHS information

1SBD350061R1000

RoHS status

Following EU Directive 2002/95/EC August 18, 2005 and amendment

Short-circuit protective devices

Auxiliary Circuit - gG Type Fuses 10 A gG Type Fuses 50 A

Terminal type

Screw terminals

UL certificate

UL_071301E39231

Ambient air temperature: Close to Contactor Fitted with Thermal O/L Relay -25 ... +55 C Close to Contactor for Storage -60 ... +80 C Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... +55 C Close to Contactor without Thermal O/L Relay (Uc) -40 ... +70 C

Coil consumption: Average Holding Value 50 / 60 Hz 12 VA Average Holding Value 50 / 60 Hz 3 W Average Pull-in Value 50 Hz 125 VA Average Pull-in Value 60 Hz 120 VA

Max breaking capacity: cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 420 A cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 170 A

Operate time: Between Coil Energization and NO Contact Closing 8 ... 21 ms Between Coil De-energization and NO Contact Opening 4 ... 11 ms Between Coil De-energization and NC Contact Closing 7 ... 14 ms Between Coil Energization and NC Contact Opening 6 ... 18 ms

Rated insulation voltage (Ui): acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V acc. to IEC 60947-5-1 and VDE 0110 (Gr. C) 690 V acc. to UL/CSA 600 V

Rated operational current AC-3 (Ie): (220 / 230 / 240 V) 55 C 26 A (380 / 400 V) 55 C 26 A (415 V) 55 C 26 A (440 V) 55 C 26 A (500 V) 55 C 22 A (690 V) 55 C 17 A

Rated operational power AC-3 (Pe): (220 / 230 / 240 V) 6.5 kW (380 / 400 V) 11 kW (415 V) 11 kW (440 V) 15 kW (500 V) 15 kW (690 V) 15 kW

Rated short-time withstand current (Icw): at 40 C Ambient Temp, in Free Air, from a Cold State 10 s 210 A at 40 C Ambient Temp, in Free Air, from a Cold State 15 min 45 A at 40 C Ambient Temp, in Free Air, from a Cold State 1 min 90 A at 40 C Ambient Temp, in Free Air, from a Cold State 1 s 400 A at 40 C Ambient Temp, in Free Air, from a Cold State 30 s 110 A for 0.1 s 140 A for 1 s 100 A