We never sell your data to third parties
IFM DL3003 MONITOR/ANALOG/IOL/AC/DC Evaluation unit for monitoring analogue standard signals
MODEL DL3003
$434.83 Each
Prices are subject to change
FREE SHIPPING ON ORDERS OVER $100
Select Quantity
Returnable: Yes
Accuracy
± 0.75
Ambient Temperature (°C)
-40...60
Ambient temperature [°C]
-40...60
Analog Current Output (Ma)
4...20
Analog current output [mA]
4...20; (max.. 20, 5 mA)
Analog Input (Current) (Ma)
0...20
Analog input (current) [mA]
0...20
Analog input (voltage) [V]
0...10
Auxiliary Energy for Sensors DC (V)
16.5...27.7
Cage Clamps
...2.5 mm²
Circuit
PNP
Communication Interface
IO-Link
Contact Rating
6 A
Current Consumption (Ma)
AC operation: max. 8 A (including maximum AC supply for additional devices )
Degree of Soiling
2
Design
housing for DIN rail mounting
Dimensions (mm)
126 x 50 x 112.4
Dimensions [mm]
126 x 50 x 112.4
Electrically Separated
No
Enclosure Type
Open Type
File Number UL
E191692
Housing
Rectangular
Input Resistance (Ω)
300
Input resistance [kΩ]
25
Input resistance [Ω]
300
IO-Link Revision
1.1
Material
housing: plastics
Max. current load per output [mA]
10
Max. height above sea level [m]
4000
Max. load [Ω]
600; (300 Ω: Operating voltage < 24 V DC)
Max. power consumption DC [W]
9
Max. relative air humidity [%]
80; (31 °C; linearly decreasing to 50 % (40 °C))
Maximum Current Load Per Output (Ma)
10
Maximum Height Above Sea Level (M)
4000
Maximum Load (Ω)
600
Maximum Power Consumption DC (W)
9
Maximum Relative Air Humidity (%)
80; (31 °C; linearly decreasing to 50 % (40 °C))
Min. process cycle time [ms]
4.9
Minimum Load Current (Ma)
10
Minimum load current [mA]
10; (> 12 V)
Minimum Process Cycle Time (Ms)
4.9
MTTF (Years)
150
MTTF [years]
150
Nominal Frequency AC (Hz)
50...60
Nominal frequency AC [Hz]
50...60
Nominal Voltage AC (V)
110...240
Nominal voltage AC [V]
110...240
Nominal Voltage DC (V)
24
Nominal voltage DC [V]
24
Number of Analog Inputs
2
Number of Analog Outputs
1
Number of Digital Outputs
2
Number of Relay Outputs
2
Operating Voltage (V)
110...240 AC / 18...30 DC
Overvoltage Category
II
Pack quantity
1 pcs.
Pollution degree
2
Power
1x LED, green / red
Protection
IP 20
Protection Rating Terminals
IP 20
Required master port class
A
Resolution of Analog Input
12 Bit
SDCI Standard
IEC 61131-9
Short-circuit Proof
Yes
Storage Temperature (°C)
-40...85
Storage temperature [°C]
-40...85
Switching Frequency AC (Hz)
< 2
Switching frequency AC [Hz]
< 2
Switching Frequency DC (Hz)
< 2
Switching frequency DC [Hz]
< 2
Switching Status
2x LED, yellow
Ta
60 °C
Teach Function
Yes
Temperature Coefficient (% of The Span / 10 K)
± 0, 1
Temperature coefficient [% of the span / 10 K]
± 0, 1; (> 45 °C)
Transmission type
COM2 (38, 4 kBaud)
Type of Mounting
Mounting on DIN rail; (TH35 (EN 60715))
- For the reliable limit monitoring of flow, pressure, temperature, or level
- With two analog inputs
- Possibility of calculating a new value based on the two input values
- Various configurable monitoring functions
- Monitoring data is provided via two relays and transistor outputs
PLCs have evolved over the years to become crucial components for driving industrial automation. This post provides insights into the PLCs to help you understand how they work. Remember that you need to pick the right PLC for your system and ensure it is installed by an expert for proper performance.
Read MoreWhen selecting a PLC for industrial application, it is prudent to consider your system requirements and targeted control. It is also prudent to work with a technical expert and only acquire the PLC that guarantees better results.
Read MoreBrand
Irwin Tools
Model
325024
Brand
Timken
Model
211
Brand
Thomson Linear
Model
511U15E1LC
Brand
RAB Lighting
Model
HAT4SB
Brand
Browning
Model
41SH32
Brand
Bridgeport
Model
281
Brand
Dodge
Model
239231
Brand
Thomson Linear
Model
511P45F2NZC