We never sell your data to third parties
$555.50 Each
Prices are subject to change
FREE SHIPPING ON ORDERS OVER $100
Select Quantity
Returnable: Yes
Accuracy
≤ 4 kHz + / -10 %; ≥ 4...10 kHz: < 3 dB
Ambient Temperature (°C)
-30...80
Ambient temperature [°C]
-30...80
BLOB
Binary Large Object Transfer
Communication Interface
IO-Link
Connector
1 x M12; coding: A; Maximum cable length: 20 m
Current Consumption (Ma)
< 50
Current consumption [mA]
< 50
Diagnostic Functions
Self-test
Dimensions (mm)
Ø 22 / L = 63.55
Dimensions [mm]
Ø 22 / L = 63.55
Electrical Design
PNP / NPN
Frequency Range (Hz)
2...10000
Frequency range [Hz]
2...10000
Housing
Tubular
In steps of
1
In Steps of (Mm/S)
0.2
In steps of [mm/s]
0.2
In steps of [°C]
2
IO-Link Revision
1.1
Linearity Deviation
2 %
Material
housing: stainless steel (1.4404 / 316L)
Max. current load per output [mA]
100
Max. voltage drop switching output DC [V]
2
Maximum Current Load Per Output (Ma)
100
Maximum Voltage Drop Switching Output DC (V)
2
Measuring Principle
Capacitive
Measuring Range (°C)
-30...80
Measuring range [°C]
-30...80
Measuring range of vibration
1...50
Measuring Range of Vibration (Mm/S)
0...45
Measuring range of vibration [mm/s]
0...45
Min. insulation resistance [MΩ]
100; (500 V DC)
Min. process cycle time [ms]
11.6
Minimum Insulation Resistance (MΩ)
100
Minimum Process Cycle Time (Ms)
3.6
MTTF (Years)
299
MTTF [years]
299
Number of Digital Outputs
2
Number of inputs and outputs
Number of digital outputs: 2
Number of Measurement Axes
1
Operating Voltage (V)
18...30 DC
Operating voltage [V]
18...30 DC
Output Function
Normally Open / Closed
Output Signal
switching signal; IO-Link
Overload Protection
Yes
Pack quantity
1 pcs.
Parameter Setting Options
Software
Process data analog
10
Process data binary
2
Protection
IP 67; IP 68; IP 69K
Protection Class
III
Required master port class
A
Reset point rP
1...49
Reset Point Rp (Mm/S)
0...44.8
Reset point rP [mm/s]
0...44.8
Reset point rP [°C]
-30...78
Resolution (°C)
0.1
Resolution [°C]
0.1
Reverse Polarity Protection
Yes
SDCI Standard
IEC 61131-9: 2013-07
Set point SP
2...50
Set Point SP (Mm/S)
0.2...45
Set point SP [mm/s]
0.2...45
Set point SP [°C]
-28...80
Short-circuit Protection
Yes
SIO mode
Yes
Status A (COM2)
1258
Status B (COM2 / COM3)
1370
Storage Temperature (°C)
-30...80
Storage temperature [°C]
-30...80
Ta
-30...70 °C
Tightening Torque (Nm)
8
Tightening torque [Nm]
8
Transmission type
COM2 (38, 4 kBaud)
Type of Mounting
Set Screw
Type of Sensor
Microelectromechanical system (MEMS)
Type of Short-circuit Protection
Yes (Non-latching)
- Condition-based maintenance thanks to monitoring of imbalance, rolling element bearing or gear state
- Large operating temperature range and high protection rating for the requirements of harsh industrial environments
- Reliable and permanent monitoring of characteristic values incl. raw data acquisition
- Integration in Industrial Ethernet systems without control cabinet and complex wiring
- Asynchronous transmission of raw data (BLOB) and integrated operating hours counter
PLCs have evolved over the years to become crucial components for driving industrial automation. This post provides insights into the PLCs to help you understand how they work. Remember that you need to pick the right PLC for your system and ensure it is installed by an expert for proper performance.
Read MoreWhen selecting a PLC for industrial application, it is prudent to consider your system requirements and targeted control. It is also prudent to work with a technical expert and only acquire the PLC that guarantees better results.
Read MoreBrand
Timken
Model
470362
Brand
Walter
Model
48R709
Brand
SealMaster
Model
703087
Brand
Timken
Model
25003-5829
Brand
Cle-Line
Model
C66070
Brand
Walter
Model
011129
Brand
Timken
Model
22309EJW33C3