A-peak (X)
16
a-RMS (X)
16
Accuracy
2-5000Hz + / - 10%, 5000...5600Hz -3dB
Accuracy [K]
± 5
Ambient Temperature (°C)
-30...80
Ambient temperature [°C]
-30...80
Binary Switching Information
2
BLOB
Binary Large Object Transfer
Communication Interface
IO-Link
Connector
1 x M12; coding: A; Contacts: 4; Maximum cable length: 20 m
Current Consumption (Ma)
< 50
Current consumption [mA]
< 50
Design
Datascience Condition Monitoring
Device Status
4
Diagnostic Functions
Self-test
Electrical Design
PNP / NPN
F (Hz)
Frequency
Fault
1 LED, red
File Number UL
E251902
Frequency Range (Hz)
2...5600
Frequency range [Hz]
2...5600
IO-Link Revision
1.1
Linearity Deviation
2
Material
housing: stainless steel (1.4404 / 316L)
Max. current load per output [mA]
100
Max. voltage drop switching output DC [V]
2
Maximum Current Load Per Output (Ma)
100
Maximum Voltage Drop Switching Output DC (V)
2
Measuring Principle
Capacitive
Measuring Range (°C)
-30...80
Measuring range [°C]
-30...80
Measuring Range of Vibration (Mm/S)
0...300
Measuring range of vibration [g]
0...16
Measuring range of vibration [mm/s]
0...300
Min. insulation resistance [MΩ]
100; (500 V DC)
Min. process cycle time [ms]
4.1
Minimum Insulation Resistance (MΩ)
100
Minimum Process Cycle Time (Ms)
4.1
MTTF (Years)
480
MTTF [years]
480
Number of Digital Outputs
2
Number of inputs and outputs
Number of digital outputs: 2
Number of Measurement Axes
3
Operating Voltage (V)
18...30 DC
Operating voltage [V]
18...30 DC
Output Function
Normally Open / Closed
Output Signal
switching signal; IO-Link
Overload Protection
Yes
Pack quantity
1 pcs.
Parameter Setting Options
IO-Link
Power
1 LED, green
Protection
IP 67; IP 68; IP 69
Protection Class
III
Required master port class
A
Reset Point Rp (Mm/S)
0...299.8
Reset point rP [g]
0...15.8
Reset point rP [mm/s]
0...299.8
Reset point rP [°C]
-30...78
Resolution (Mm/S)
0.1
Resolution [g]
0.001
Resolution [mm/s]
0.1
Resolution [°C]
0.1
Reverse Polarity Protection
Yes
Scaling / A-peak/a-RMS
8
Scaling / Temperature
8
Scaling / v-RMS
8
SDCI Standard
IEC 61131-9: 2013-07
Set Point SP (Mm/S)
0.2...300
Set point SP [g]
0.2...16
Set point SP [mm/s]
0.2...300
Set point SP [°C]
-28...80
Short-circuit Protection
Yes
SIO mode
Yes
Standard
mechanical vibration; ISO 10816-3; ISO 2954; ISO 20816-3
Storage Temperature (°C)
-30...80
Storage temperature [°C]
-30...80
Temperature
16
Tightening Torque (Nm)
4.6
Tightening torque [Nm]
4.6
Transmission type
COM3 (230, 4 kBaud)
Type of Mounting
Mounting Screw
Type of Sensor
Microelectromechanical system (MEMS)
Type of Short-circuit Protection
Yes (Non-latching)
Unbalance / Bearing Event
1
v-RMS (X)
16
Virtual Switching Output (V-ou1)
1
- reliable and permanent monitoring of condition parameters in 3 axes
- condition-based analysis of imbalance and rolling element bearing damages
- suited for harsh industrial environments, with sensor self-test and status LED
- asynchronous transmission of raw data (BLOB) and integrated characteristic value history
PLCs have evolved over the years to become crucial components for driving industrial automation. This post provides insights into the PLCs to help you understand how they work. Remember that you need to pick the right PLC for your system and ensure it is installed by an expert for proper performance.
Read MoreWhen selecting a PLC for industrial application, it is prudent to consider your system requirements and targeted control. It is also prudent to work with a technical expert and only acquire the PLC that guarantees better results.
Read MoreBrand
Royal Products
Model
45136
Brand
Cleveland
Model
C63553
Brand
RAB Lighting
Model
PLED52
Brand
Cleveland
Model
C80932
Brand
Irwin Tools
Model
641
Brand
Irwin Tools
Model
251
Brand
Irwin Tools
Model
4935580