Accuracy (In The Measuring Range)
± (1, 0 % MW + 0, 5 % MEW)
Accuracy [K]
± 2, 5 (Q > 5 % MEW)
Accuracy Class
1, 5
Ambient Temperature (°C)
-20...60
Ambient temperature [°C]
-20...60
Analog Current Output (Ma)
4...20
Analog current output [mA]
4...20
Analog End Point (°C)
4...100
Analog end point [°C]
4...100
Analog Start Point (°C)
-20...76
Analog start point [°C]
-20...76
BLOB
Binary Large Object Transfer
Communication Interface
IO-Link
Connector
1 x M12; coding: A; Contacts: 4, gold-plated
Current Consumption (Ma)
< 75
Current consumption [mA]
< 75
Damping Process Value dAP (S)
0...5
Damping process value dAP [s]
0...5
Diagnosis
1 x LED, three-color
Diagnostic functions
Direction of flow detection; signal quality
Dimensions (mm)
130 x 48 x 65.2
Dimensions [mm]
130 x 48 x 65.2
DIN IEC 68-2-27
20 g (11ms)
DIN IEC 68-2-6
20 g (10...2000Hz)
Display Range (°C)
-44...124
Display range [°C]
-44...124
Dynamic Response T05 / T09 (S)
5, 7 / 86
Dynamic response T05 / T09 [s]
5, 7 / 86
Electrical Design
PNP / NPN
File Number UL
E174189
Flow Monitoring
32
Frequency At The End Point FRP (Hz)
1...10000
Frequency at the end point FRP [Hz]
1...10000
Frequency End Point, FEP (°C)
4...100
Frequency end point, FEP [°C]
4...100
Frequency Start Point, FSP (°C)
-20...76
Frequency start point, FSP [°C]
-20...76
Housing
Rectangular
Inputs
Counter Reset
IO-Link Revision
1.1.3
Max. load [Ω]
500
Max. voltage drop switching output DC [V]
2
Maximum Load (Ω)
500
Maximum Voltage Drop Switching Output DC (V)
2
Measuring Principle
Ultrasonic
Measuring Range (°C)
-20...100
Measuring range [°C]
-20...100
Media
Ultra-pure Water; Water; Water-based Media
Medium Temperature (°C)
-20...100
Medium temperature [°C]
-20...100
Min. process cycle time [ms]
9.6
Minimum Process Cycle Time (Ms)
9.6
Model Number
002US
MTTF (Years)
160
MTTF [years]
160
Operating Voltage (V)
18...32 DC
Operating voltage [V]
18...32 DC; (to SELV/PELV)
Output 1
1
Output 2
1
Output Function
Normally Open / Closed
Overload Protection
Yes
Pack quantity
1 pcs.
Permanent Current Rating of Switching Output DC (Ma)
100
Permanent current rating of switching output DC [mA]
100
Power-on Delay Time (S)
5
Power-on delay time [s]
5
Pressure Equipment Directive
Can Be Used for Group 2 Fluids; Group 1 Fluids On Request
Process Connection
threaded connection G 1 external thread DN25
Process data analog
3
Process data binary
2
Protection
IP 65; IP 67
Protection Class
III
Pulse Length (S)
0.002...2
Pulse length [s]
0.002...2
Pulse Output
Flow Rate Meter
Pulse Value
0.02...99990000 I
Repeatability
± 0, 2 % MEW
Required master port class
A
Reset Point Rp (°C)
-20...99.6
Reset point rP [°C]
-20...99.6
Resolution (°C)
0.1
Resolution [°C]
0.1
Response Time (S)
< 0.25
Response time [s]
< 0.25; (dAP = 0, T09)
Reverse Polarity Protection
Yes
SDCI Standard
IEC 61131-9: 2013-07
Set Point SP (°C)
-19.6...100
Set point SP [°C]
-19.6...100
Short-circuit Protection
Yes
Special feature
Gold-plated contacts
Status
4
Storage Temperature (°C)
-25...80
Storage temperature [°C]
-25...80
Surface Characteristics Ra/Rz of The Wetted Parts
Ra < 1.25 µm
Switching Frequency DC (Hz)
0...10000
Switching frequency DC [Hz]
0...10000
Switching Function
2 x LED, yellow
Temperature Coefficient (% of The Span / 10 K)
0, 2
Temperature coefficient [% of the span / 10 K]
0, 2
Temperature Monitoring
32
Total Number of Outputs
2
Totalizer
32
Transmission type
COM2 (38, 4 kBaud)
Type of Mounting
inlet pipe length 5xDN; outlet pipe length 1xDN
Type of Short-circuit Protection
Yes (Non-latching)
Vacuum Resistance (Mbar)
-1000
Vacuum resistance [mbar]
-1000
- Accurate flow measurement of ultrapure water and water
- A robust, component-free measuring pipe made of stainless steel offers high media resistance and permanent ingress resistance
- The highly accurate inline measurement process eliminates any influence of varying wall thicknesses and pipe materials
- Operating status LED signals the sensor status and allows conclusions about process quality
PLCs have evolved over the years to become crucial components for driving industrial automation. This post provides insights into the PLCs to help you understand how they work. Remember that you need to pick the right PLC for your system and ensure it is installed by an expert for proper performance.
Read MoreWhen selecting a PLC for industrial application, it is prudent to consider your system requirements and targeted control. It is also prudent to work with a technical expert and only acquire the PLC that guarantees better results.
Read MoreBrand
Dodge
Model
041943
Brand
IFM
Model
EC0702
Brand
IFM
Model
EVF615
Brand
WEG
Model
ALSD0
Brand
IFM
Model
EVCC06
Brand
IFM
Model
EBC010
Brand
IFM
Model
EVCB56
Brand
IFM
Model