Returnable: Yes
Additional Voltage Supply (V)
20...30 DC
Additional voltage supply [V]
20...30 DC; (UA)
Ambient Temperature (°C)
-25...60
Ambient temperature [°C]
-25...60
Communication Interface
Ethernet; IO-Link
Connector
1 x M12; coding: L; Contacts: 5; sealing: FKM
Current Consumption (Ma)
300...3900
Current consumption [mA]
300...3900; (US)
Current Rating Per Port (A)
2
Current rating per port [A]
2; (adjustable: 0...2; Factory setting: 2)
Daisy-chain Function
Voltage Supply; Fieldbus Interface
Degree of Soiling
2
Digital Inputs Protected Against Short Circuits
Yes
Dimensions (mm)
208 x 59.3 x 38.4
Dimensions [mm]
208 x 59.3 x 38.4
Housing
Rectangular
IO-Link Revision
1.1
Material
housing: PA orange; Socket: brass nickel-plated
Max. current load per output [mA]
2000
Max. current load total [A]
8
Max. relative air humidity [%]
90
Maximum Current Load Per Output (Ma)
2000
Maximum Current Load Total (A)
3.6
Maximum Relative Air Humidity (%)
90
NEMA 250 5.13.1
AA
Number of Digital Inputs
12
Number of Digital Outputs
12
Number of inputs and outputs
Number of digital inputs: 12; Number of digital outputs: 12
Number of Ports Class A
4
Number of Ports Class B
4
Operating Voltage (V)
20...30 DC
Operating voltage [V]
20...30 DC; (US ; to PELV)
Overvoltage Category
II
Pack quantity
1 pcs.
Pollution degree
2
Protection
IP 65; IP 66; IP 67
Protection Class
III
Protection Rating (NEMA 250)
6P
Protocol
PROFINET; OPC UA
Sealing Material
FKM
Short-circuit Proof
Yes
Storage Temperature (°C)
-25...85
Storage temperature [°C]
-25...85
Switching Level High (V)
11...30
Switching level high [V]
11...30
Switching Level Low (V)
0...5
Switching level low [V]
0...5
Total Number of Inputs and Outputs
16
Transmission Rate
100 MBit / s
Transmission Standard
10Base-T; 100Base-TX
Transmission type
COM1 (4, 8 kBaud); COM2 (38, 4 kBaud); COM3 (230, 4 kBaud)
Type of Mounting
Backplane Mounting
- Daisy-chain power supply with standardized L-coded M12 connection technology
- Configurable current limitation for each port to ensure safe operation
- Voltage and current measurement per port for energy monitoring
- Connection of actuators up to 2 A
- Integrated OPC UA server
PLCs have evolved over the years to become crucial components for driving industrial automation. This post provides insights into the PLCs to help you understand how they work. Remember that you need to pick the right PLC for your system and ensure it is installed by an expert for proper performance.
Read MoreWhen selecting a PLC for industrial application, it is prudent to consider your system requirements and targeted control. It is also prudent to work with a technical expert and only acquire the PLC that guarantees better results.
Read MoreBrand
Cleveland
Model
C64116
Brand
SKF Seals
Model
21241
Brand
Nexen
Model
967261
Brand
RAB Lighting
Model
BLEDR18Y/D10
Brand
Dodge
Model
P2B-SCB-104-HT
Brand
SealMaster
Model
704224