We never sell your data to third parties
IFM GI506S GIIA-4030-3PT/SIL3/V4A/US Fail-safe inductive sensor
MODEL GI506S
$271.70 Each
Prices are subject to change
FREE SHIPPING ON ORDERS OVER $100
Select Quantity
Returnable: Yes
Air Pressure (Kpa)
80...106
Air pressure [kPa]
80...106
Ambient Temperature (°C)
10...40
Ambient temperature [°C]
0...70
Applications
Class C to EN 60654-1 weatherproof application
Connector
1 x M12; coding: A; Contacts: gold-plated
Current Consumption (Ma)
< 15
Current consumption [mA]
< 15
Dimensions (mm)
M30 x 1.5 / L = 80
Dimensions [mm]
M30 x 1.5 / L = 80
Enable Zone (mm)
6...12
Enable zone [mm]
6...12
Housing
Threaded Type
Ionizing Radiation
Not Permissible
Material
Housing: stainless steel; sensing face: PEEK; O-ring: FKM
Max. capacitive load CL_max [nF]
20
Max. input capacitance Ci_max [nF]
2
Max. power-on delay time [ms]
5000
Max. relative air humidity [%]
Briefly: 5...95 %; permanent: 5...70 %
Maximum Capacitive Load CL_Max (Nf)
20
Maximum Input Capacitance Ci_Max (Nf)
2
Maximum Power-on Delay Time (Ms)
5000
Maximum Relative Air Humidity (%)
briefly: 5...95 %; permanent: 5...70 %
MIssion Time TM (H)
≤ 175200
MIssion time TM [h]
≤ 175200
Mounting
Non-flush Mountable
Operating Voltage (V)
19.2...30 DC
Operating voltage [V]
19.2...30 DC
Output Data
Interface Type B
Output Function
Clock Signal
Pack quantity
1 pcs.
PFH (1/H)
0.00000001
PFH [1/h]
1E-08
Power
1 x LED, green
Protection
IP 68; IP 69K
Protection Class
III
Rate of Temperature Change (K/Min)
0.5
Rate of temperature change [K/min]
0.5
Response Time To Safety Request (Ms)
20
Response time to safety request [ms]
20
Response Time When Approaching The Enable Zone (Ms)
200
Response time when approaching the enable zone [ms]
200; (typical 100)
Reverse Polarity Protection
Yes
Safe Switching-off Distance S(Ar) (mm)
30
Safe switching-off distance s(ar) [mm]
30
Safety-related sub-function
Safe state when undamped correctly (s > sAs (sar))
Salt Spray
No
Short-circuit Protection
Yes
Signal
1 x LED, yellow
Special feature
Gold-plated contacts
Thread Designation
M30 X 1.5
Type of operation
Continuous operation (maintenance-free)
- For ensuring machine safety
- Certified to the following standards: EN 60947-5-3, IEC 61508 and ISO 13849
- No special actuator for electronic fail-safe sensors required
- Direct connection to safe ifm relays
- Series connection of sensors possible
PLCs have evolved over the years to become crucial components for driving industrial automation. This post provides insights into the PLCs to help you understand how they work. Remember that you need to pick the right PLC for your system and ensure it is installed by an expert for proper performance.
Read MoreWhen selecting a PLC for industrial application, it is prudent to consider your system requirements and targeted control. It is also prudent to work with a technical expert and only acquire the PLC that guarantees better results.
Read MoreBrand
AXIS
Model
AXS 87502
Brand
Hubbell Wiring
Model
5252ST
Brand
Timken
Model
21158-0832
Brand
Dodge
Model
F4B-E-207R-DRY
Brand
Timken
Model
24700-3880
Brand
Linn Gear
Model
60A14
Brand
Berliss
Model
95348