GI855S

Image for Illustration purposes only. Actual product may vary

View in markdown

IFM GI855S GIIK4010B2PO/SIL2/US Fail-safe inductive sensor

MODEL GI855S

BRAND

IFM

SKU

96943649

UOM

each

$202.07 Each

Prices are subject to change

FREE SHIPPING ON ORDERS OVER $100

Select Quantity

GET A QUOTE

Returnable: Yes

Ambient Temperature (°C)

-40...85

Ambient temperature [°C]

-40...85

Connector

1 x M12; coding: A; Contacts: gold-plated

Correction Factor

steel: 1 / stainless steel: 0.7 / brass: 0.5 / aluminum: 0.4 / copper: 0.4

Current Consumption (Ma)

< 20

Current consumption [mA]

< 20

Dimensions (mm)

M30 x 1.5 / L = 65

Dimensions [mm]

M30 x 1.5 / L = 65

Display Switching Status

4 LED, yellow

Electrical Design

PNP

Enable Zone (mm)

> 14.5

Enable zone [mm]

> 14.5

Housing

Threaded Type

Hysteresis (% of Sr)

1...10

Hysteresis [% of Sr]

1...10

Ionizing Radiation

Not Permissible

ISO 10605 ESD

8 kV CD / 15 kV AD

ISO 11452-2, ISO 11452-5 Radiated Immunity

100 V / m

ISO 7637-2, ISO 16750-2 Conducted Immunity

12 V / 24 V

Max. capacitive load CL_max [nF]

20

Max. height above sea level [m]

5000

Max. power-on delay time [ms]

1000

Max. relative air humidity [%]

50; (70 °C; <70 °C: >50 %)

Max. voltage drop switching output DC [V]

2.5; (30 mA)

Maximum Capacitive Load CL_Max (Nf)

20

Maximum Height Above Sea Level (M)

5000

Maximum Power-on Delay Time (Ms)

1000

Maximum Relative Air Humidity (%)

50

Maximum Voltage Drop Switching Output DC (V)

2.5

Minimum Load Current (Ma)

1

Minimum load current [mA]

1

MIssion Time TM (H)

≤ 87600

MIssion time TM [h]

≤ 87600

Mounting

Flush Mountable

MTTF (Years)

781

MTTF [years]

781

Operating Voltage (V)

8...32 DC

Operating voltage [V]

8...32 DC

Output Data

Interface Type C Class 1

Output Function

2 x OSSD (A1 and A2)

Output Voltage At 24 V

compatible with EN 61131-2 inputs type 1, 2

Overload Protection

Yes

Pack quantity

1 pcs.

Permanent Current Rating of Switching Output DC (Ma)

50

Permanent current rating of switching output DC [mA]

50

PFH (1/H)

< 5E-08

PFH [1/h]

< 5E-08

Protection

IP 65; IP 67; IP 68; IP 69K

Protection Class

III

Pulse

1 2a 3a 3b 4 5b

Rated Insulation Voltage (V)

60

Rated insulation voltage [V]

60

Response Time To Safety Request (Ms)

5

Response time to safety request [ms]

5

Response Time When Approaching The Enable Zone (Ms)

5

Response time when approaching the enable zone [ms]

5

Reverse Polarity Protection

Yes

Risk Time (Response Time for Safety-related Faults) (Ms)

100

Risk time (response time for safety-related faults) [ms]

100

Safe Switch-off Distance S(Ao) (mm)

< 8

Safe switch-off distance s(ao) [mm]

< 8

Safety-related Sub-function

Safe State When Damped Correctly

Severity Level

III III III III III III 58V

Short-circuit Protection

Yes

Special feature

Gold-plated contacts

Switching Frequency DC (Hz)

10

Switching frequency DC [Hz]

10

The Following Media Were Tested for 10 Minutes At 23 °C

Premium-grade Petrol Lead-free

The Following Media Were Tested for 2 Hours At 23 °C

Wheel Rim Cleaner

The Following Media Were Tested for 22 Hours At 23 °C

Corrosion Protection

The Following Media Were Tested for 22 Hours At 60 °C

Coolants

The Following Media Were Tested for 22 Hours At 75 °C

Hydraulic Fluids

Thread Designation

M30 X 1.5

Tightening Torque (Nm)

< 50

Tightening torque [Nm]

< 50

Type of operation

Permanent operation

  • Certified to the following standards: EN 60947-5-3, IEC 61508 and ISO 13849
  • Connection to safety PLC, safe AS-i modules or safe evaluation units
  • Ensuring operator and machine safety

Aug. 15, 2019

PLCs have evolved over the years to become crucial components for driving industrial automation. This post provides insights into the PLCs to help you understand how they work. Remember that you need to pick the right PLC for your system and ensure it is installed by an expert for proper performance.

Read More

 
Aug. 14, 2019

When selecting a PLC for industrial application, it is prudent to consider your system requirements and targeted control. It is also prudent to work with a technical expert and only acquire the PLC that guarantees better results.

Read More

 
Recently Viewed
294232

#96663181

Brand

Dodge

Model

294232

$2,906.08 Each
Free shipping
E10447

#96942718

Brand

IFM

Model

E10447

$154.88 Each
Free shipping
10B15FJ

#823339

Brand

U.S.Tsubaki

Model

10B15FJ

$28.92 Each
Free Shipping orders over $100
109A0030A

#5775679

Brand

Remke

Model

109A0030A

$72.48 Each
Free Shipping orders over $100
293406

#96684497

Brand

Dodge

Model

293406

$2,626.23 Each
Free shipping
TMPCBS04

#864920

Brand

Red Lion Controls

Model

TMPCBS04

Click for 5% off
$44.63 Each
Free Shipping orders over $100
80-7235

#2937833

Brand

Dongan

Model

80-7235

$840.13 Each