We never sell your data to third parties
IFM GM705S GIMC-4045-US/2OSSD Fail-safe inductive sensor
MODEL GM705S
$467.50 Each
Prices are subject to change
FREE SHIPPING ON ORDERS OVER $100
Select Quantity
Typically Ships in: 1 day
Returnable: Yes
Air Pressure (Kpa)
80...106
Air pressure [kPa]
80...106
Ambient Temperature (°C)
10...40
Ambient temperature [°C]
-25...60
Applications
Class C to EN 60654-1 weatherproof application
Connector
1 x M12; coding: A; Contacts: gold-plated
Current Consumption (Ma)
< 30
Current consumption [mA]
< 30
Dimensions (mm)
40 x 40 x 66
Dimensions [mm]
40 x 40 x 66
Electrical Design
PNP
Enable Zone (mm)
4...20
Enable zone [mm]
4...20
Housing
Rectangular
Ionizing Radiation
Not Permissible
Material
PPE; diecast zinc
Max. capacitive load CL_max [nF]
20
Max. height above sea level [m]
2000
Max. power-on delay time [ms]
5000
Max. relative air humidity [%]
Briefly: 5...95 %; permanent: 5...70 %
Max. voltage drop switching output DC [V]
2.5; (100 mA)
Maximum Capacitive Load CL_Max (Nf)
20
Maximum Height Above Sea Level (M)
2000
Maximum Power-on Delay Time (Ms)
5000
Maximum Relative Air Humidity (%)
briefly: 5...95 %; permanent: 5...70 %
Maximum Voltage Drop Switching Output DC (V)
2.5
MIssion Time TM (H)
≤ 175200
MIssion time TM [h]
≤ 175200
Mounting
Non-flush Mountable
Operating Voltage (V)
19.2...30 DC
Operating voltage [V]
19.2...30 DC
Output Data
Interface Type C Class 0
Output Function
2 x OSSD (A1 and A2)
Output Voltage At 24 V
compatible with EN 61131-2 inputs type 1, 2, 3
Pack quantity
1 pcs.
PFH (1/H)
0.00000001
PFH [1/h]
1E-08
Power
1 x LED, green
Protection
IP 65; IP 67
Protection Class
III
Rate of Temperature Change (K/Min)
0.5
Rate of temperature change [K/min]
0.5
Rated Insulation Voltage (V)
30
Rated insulation voltage [V]
30
Response Time To Safety Request (Ms)
50
Response time to safety request [ms]
50
Response Time When Approaching The Enable Zone (Ms)
200
Response time when approaching the enable zone [ms]
200
Reverse Polarity Protection
Yes
Risk Time (Response Time for Safety-related Faults) (Ms)
100
Risk time (response time for safety-related faults) [ms]
100
Safe Switching-off Distance S(Ar) (mm)
45
Safe switching-off distance s(ar) [mm]
45
Safety-related Sub-function
Safe State When Properly Undamped
Salt Spray
No
Short-circuit Protection
Yes
Signal
1 x LED, yellow
Special feature
Gold-plated contacts
Type of operation
Continuous operation (maintenance-free)
- For ensuring machine safety
- Certified to the following standards: EN 60947-5-3, IEC 61508 and ISO 13849
- No special actuator for electronic fail-safe sensors required
- Connection to safety PLC and safe evaluation units
PLCs have evolved over the years to become crucial components for driving industrial automation. This post provides insights into the PLCs to help you understand how they work. Remember that you need to pick the right PLC for your system and ensure it is installed by an expert for proper performance.
Read MoreWhen selecting a PLC for industrial application, it is prudent to consider your system requirements and targeted control. It is also prudent to work with a technical expert and only acquire the PLC that guarantees better results.
Read MoreBrand
Schunk
Model
1379351
Brand
SMC
Model
EX600-SPN3