Returnable: Yes
Accuracy (In The Measuring Range)
10 % MW ± 25 µS / cm
Accuracy [K]
20...50 °C: < ± 0, 5 K; -25...150 °C: < ± 1, 5 K
Ambient Temperature (°C)
-40...60
Ambient temperature [°C]
-40...60
Analog Current Output (Ma)
4...20
Analog current output [mA]
4...20
Communication Interface
IO-Link
Connector
1 x M12 (EN 61067-2-101); coding: A; Contacts: gold-plated
Current Consumption (Ma)
< 60
Current consumption [mA]
< 60
Drift (%/K)
0, 2 % / K MW ± 25 µS / cm
Drift [%/K]
0, 2 %/K MW ± 25 µS/cm
File Number UL
E364788
IO-Link Revision
1.1
Long-term Stability
1 % MW ± 25 µS / cm
Material
stainless steel (1.4404 / 316L); PEEK; PEI; FKM
Materials (Wetted Parts)
PEEK; stainless steel (1.4404 / 316L)
Max. load [Ω]
500
Maximum Load (Ω)
500
Measuring Principle
Konduktiv
Measuring Range (µS/Cm)
100...15000
Measuring range [°C]
-25...150
Measuring range [µS/cm]
100...15000
Media
Conductive Liquids
Medium Temperature (°C)
-25...100
Medium temperature [°C]
-25...100; (< 1 h: 150)
Min. process cycle time [ms]
6.4
Minimum Process Cycle Time (Ms)
6.4
MTTF (Years)
172
MTTF [years]
172
Number of Analog Outputs
1
Number of inputs and outputs
Number of analog outputs: 1
Operating Voltage (V)
18...30 DC
Operating voltage [V]
18...30 DC
Output Signal
analog signal; IO-Link
Pack quantity
1 pcs.
Power-on Delay Time (S)
2
Power-on delay time [s]
2
Process Connection
Threaded Connection G 1 / 2 External Thread Sealing Cone
Process data analog
1
Protection
IP 68; IP 69K
Protection Class
III
Repeatability
5 % MW ± 25 µS / cm
Repeatability [K]
0, 2
Required master port class
A
Resolution (µS/Cm)
1
Resolution [K]
0.1
Resolution [µS/cm]
1
Response Time (S)
< 9
Response time [s]
< 2; (T09; Damping = 0)
Reverse Polarity Protection
Yes
SDCI Standard
IEC 61131-9
SIO mode
No
Special feature
Gold-plated contacts
Storage Temperature (°C)
-40...85
Storage temperature [°C]
-40...85
Surface Characteristics Ra/Rz of The Wetted Parts
Ra ≤ 0.8 µm
Total Number of Outputs
1
Transmission type
COM2 (38, 4 kBaud)
Vacuum Resistance (Mbar)
-1000
Vacuum resistance [mbar]
-1000
- Reduce inaccuracies associated with a time-based cleaning process
- Improve process performance with flexible measurement points
- Compact, high-quality sensor design prevents failures and unplanned downtime
PLCs have evolved over the years to become crucial components for driving industrial automation. This post provides insights into the PLCs to help you understand how they work. Remember that you need to pick the right PLC for your system and ensure it is installed by an expert for proper performance.
Read MoreWhen selecting a PLC for industrial application, it is prudent to consider your system requirements and targeted control. It is also prudent to work with a technical expert and only acquire the PLC that guarantees better results.
Read MoreBrand
Meltric
Model
63-68076
Brand
Goulds
Model
SIM3012060LS2
Brand
Timken
Model
29602-4144
Brand
ACME
Model
WI001M10
Brand
Timken
Model
29507-7607
Brand
Fibox
Model
ULTPC 2419111
Brand
Hubbell Wiring
Model
CLAMPB
Brand
Thomson Linear
Model
HD24B045-0200ELP1EMS