We never sell your data to third parties
IFM RM9007 RMS0024-C24/US6 Absolute multiturn encoder with solid shaft
MODEL RM9007
$503.91 Each
Prices are subject to change
FREE SHIPPING ON ORDERS OVER $100
Select Quantity
Returnable: Yes
Accuracy (°)
0.08
Accuracy [°]
0.08
Ambient Temperature (°C)
-40...85
Ambient temperature [°C]
-40...85
Code
Binary
Communication Interface
CAN
Connector
1 x M12, axial; coding: A
Current Consumption (Ma)
< 100; ((10 V DC); ≤ 50 (24 V DC))
Current consumption [mA]
< 100; ((10 V DC) ; ≤ 50 (24 V DC))
Dimensions (mm)
Ø 58 / L = 39
Dimensions [mm]
Ø 58 / L = 39
Fixing Flange
Synchro-flange
Function Principle
Absolute
Housing
Tubular
Material
flange: aluminum; housing cap: steel
Max. revolution, mechanical [U/min]
12000
Max. shaft load axial (at the shaft end) [N]
40
Max. shaft load radial (at the shaft end) [N]
110
Max. starting torque [Nm]
0.03
Maximum Revolution, Mechanical (U/Min)
12000
Maximum Shaft Load Axial (At The Shaft End) (N)
40
Maximum Shaft Load Radial (At The Shaft End) (N)
110
Maximum Starting Torque (Nm)
0.03
MTTF (Years)
240
MTTF [years]
240
Number of CAN Interfaces
1
Operating Voltage (V)
9...30 DC
Operating voltage [V]
9...30 DC
Output Function
CANopen interface
Pack quantity
1 pcs.
Protection
IP 65
Protection Class
III
Protocol
CANopen
Reference Temperature Torque (°C)
20
Reference temperature torque [°C]
20
Resolution
4096 steps; 4096 revolutions; 24 bit
Reverse Polarity Protection
Yes
Revolution Type
Multiturn
Shaft Design
Solid Shaft
Shaft Diameter (mm)
6
Shaft diameter [mm]
6
Short-circuit Protection
Yes
Terminating Resistor
Yes
Version
DSP - 406 V3.1; DS 301 V4.02; DS 306 V2.0
- Absolute position traceability even when unpowered
- Direct output of the values via CANopen interface
- Robust housing for use in harsh industrial environments
- High shock and vibration resistance
PLCs have evolved over the years to become crucial components for driving industrial automation. This post provides insights into the PLCs to help you understand how they work. Remember that you need to pick the right PLC for your system and ensure it is installed by an expert for proper performance.
Read MoreWhen selecting a PLC for industrial application, it is prudent to consider your system requirements and targeted control. It is also prudent to work with a technical expert and only acquire the PLC that guarantees better results.
Read MoreBrand
Walter
Model
094156
Brand
Thomson Linear
Model
511H15A0NZC
Brand
Cle-Line
Model
C66095
Brand
Timken
Model
240435
Brand
Dormer Pramet
Model
5972522
Brand
Dodge
Model
202381