Accuracy (in the measuring range)
± (5% MW + 5 µm); (pressure 1...3 bar)
Ambient Temperature (°C)
0...60
Ambient temperature [°C]
0...60
Analog Current Output (Ma)
4...20
Analog current output [mA]
4...20; (scalable)
Analog End Point (Bar)
2.2...16
Analog end point [bar]
2.2...16
Analog end point AEP
200...1000
Analog End Point AEP (µM)
100...500
Analog end point AEP [µm]
100...500
Analog Start Point (Bar)
-1...12.8
Analog start point [bar]
-1...12.8
Analog start point ASP
0...800
Analog Start Point ASP (µM)
0...400
Analog start point ASP [µm]
0...400
Characteristics Deviation (% of The Final Value)
< ± 0, 5
Characteristics deviation [% of the final value]
< ± 0, 5; (BFSL = Best Fit Straight Line)
Communication Interface
IO-Link
Connector
1 x M12; coding: A
Current Consumption (Ma)
< 80
Current consumption [mA]
< 80
Damping Process Value dAP (S)
0...5
Damping process value dAP [s]
0...5
Dimensions (mm)
182 x 45.4 x 67.8
Dimensions [mm]
182 x 45.4 x 67.8
Display Range (Bar)
-1...20
Display range [bar]
-1...20
Electrical Design
PNP / NPN
File Number UL
E174189
Greatest TEMPCO of The Span (% MEW / 10 K)
± 0, 3
Greatest TEMPCO of the span [% MEW / 10 K]
± 0, 3
Greatest TEMPCO of The Zero Point (% MEW / 10 K)
± 0, 1
Greatest TEMPCO of the zero point [% MEW / 10 K]
± 0, 1
Housing
Rectangular
In steps of
1
In Steps of (µM)
1
In steps of [bar]
0.01
In steps of [µm]
1
Inputs
Teach Input
IO-Link Revision
1.1
Max. load [Ω]
500
Max. relative air humidity [%]
90
Max. voltage drop switching output DC [V]
2.5
Maximum Load (Ω)
500
Maximum Relative Air Humidity (%)
90
Maximum Voltage Drop Switching Output DC (V)
2.5
Measuring range
0...800
Measuring Range (µM)
0...400
Measuring range [bar]
-1...16
Measuring range [µm]
0...400; (depending on the nozzle used)
Media
Compressed Air
Medium Temperature (°C)
-10...60
Medium temperature [°C]
-10...60
Min. process cycle time [ms]
5.9
Minimum Process Cycle Time (Ms)
5.9
MTTF (Years)
167
MTTF [years]
167
Number of Analog Outputs
1
Number of Digital Outputs
2
Number of inputs and outputs
Number of digital outputs: 2; Number of analog outputs: 1
Operating Voltage (V)
18...30 DC
Operating voltage [V]
18...30 DC; (to SELV/PELV)
Output Function
Normally Open / Closed
Output Signal
switching signal; analog signal; IO-Link
Overload Protection
Yes
Permanent Current Rating of Switching Output DC (Ma)
150
Permanent current rating of switching output DC [mA]
150; (per output)
Power-on Delay Time (S)
1
Power-on delay time [s]
1
Pressure Equipment Directive
Sound Engineering Practice; Can Be Used for Stable Gases Fluid Group 2
Process Connection
threaded connection G 1 / 4 Internal thread DN8
Process data analog
7
Process data binary
2
Protection
IP 65; IP 67
Protection Class
III
Repeatability
± (0, 8 % MW + 0, 4 % MEW)
Repeatability [% of the final value]
± 0, 2
Required master port class
A
Reset point rP
0...996
Reset Point Rp (µM)
0...498
Reset point rP [bar]
-1...15.92
Reset point rP [µm]
0...498
Resolution
1
Resolution (µM)
1
Resolution [bar]
0.05
Resolution [µm]
1
Response Time (S)
0.1
Response time [s]
0.05
Reverse Polarity Protection
Yes
SDCI Standard
IEC 61131-9
Set point SP
4...1000
Set Point SP (µM)
2...500
Set point SP [bar]
-0.92...16
Set point SP [µm]
2...500
Setting range
0...1000
Setting Range (µM)
0...500
Setting range [µm]
0...500; (depending on the nozzle used)
Short-circuit Protection
Yes
SIO mode
Yes
Storage Temperature (°C)
-20...85
Storage temperature [°C]
-20...85
Temperature Coefficient (1/K)
± 0, 07 % MW
Temperature coefficient [1/K]
± 0, 07 % MW
Transmission type
COM2 (38, 4 kBaud)
Type of Short-circuit Protection
Yes (Non-latching)
- Air gap provided as absolute value
- Precise values at all times due to pressure-compensated measuring principle
- Enables zero gap and clogging detection
- Self-cleaning measuring channel resists purge air pressure
- Easy teaching of thresholds with just one click
PLCs have evolved over the years to become crucial components for driving industrial automation. This post provides insights into the PLCs to help you understand how they work. Remember that you need to pick the right PLC for your system and ensure it is installed by an expert for proper performance.
Read MoreWhen selecting a PLC for industrial application, it is prudent to consider your system requirements and targeted control. It is also prudent to work with a technical expert and only acquire the PLC that guarantees better results.
Read MoreBrand
IFM
Model
AC2250
Brand
Flowtrend
Model
60498
Brand
Dichtomatik
Model
75115108
Brand
FEIN
Model
63134999036
Brand
Walter
Model
H-0300
Brand
Walter
Model
9937-BHTG