SD1540

Image for Illustration purposes only. Actual product may vary

View in markdown

IFM SD1540 SDD11DGXFRKG/US-100 Compressed air meter

MODEL SD1540

BRAND

IFM

SKU

96944158

UOM

each

$1,227.60 Each

Prices are subject to change

FREE SHIPPING ON ORDERS OVER $100

Select Quantity

GET A QUOTE

Returnable: Yes

Accuracy (In The Measuring Range)

± (6 % MW + 0, 6 % MEW)

Accuracy Class

-

Ambient Temperature (°C)

0...60

Ambient temperature [°C]

0...60

Analog Current Output (Ma)

4...20

Analog current output [mA]

4...20; (scalable)

Analog End Point (Bar)

2.2...16

Analog end point [bar]

2.2...16

Analog Start Point (Bar)

-1...12.8

Analog start point [bar]

-1...12.8

Characteristics Deviation (% of The Final Value)

< ± 0, 5

Characteristics deviation [% of the final value]

< ± 0, 5; (BFSL = Best Fit Straight Line)

Communication Interface

IO-Link

Connector

1 x M12; coding: A

Current Consumption (Ma)

< 80

Current consumption [mA]

< 80

Damping Process Value dAP (S)

0...5

Damping process value dAP [s]

0...5

Dimensions (mm)

85.1 x 45.8 x 100.3

Display Range (Bar)

-1...20

Display range [bar]

-1...20

Dynamic Response T05 / T09 (S)

T09 = 0, 5

Dynamic response T05 / T09 [s]

T09 = 0, 5

Electrical Design

PNP / NPN

File Number UL

E174189

Greatest TEMPCO of The Span (% MEW / 10 K)

± 0, 3

Greatest TEMPCO of the span [% MEW / 10 K]

± 0, 3

Greatest TEMPCO of The Zero Point (% MEW / 10 K)

± 0, 1

Greatest TEMPCO of the zero point [% MEW / 10 K]

± 0, 1

Housing

Rectangular

In Steps of (Bar)

0.01

In steps of [bar]

0.01

Inputs

Counter Reset

Installation

Adjustable To Inside Pipe Diameters

IO-Link Revision

1.1

MAWP (for Applications According To CRN) (Bar)

10

MAWP (for applications according to CRN) [bar]

10

Max. load [Ω]

500

Max. relative air humidity [%]

90

Max. voltage drop switching output DC [V]

2.5

Maximum Allowable Error

± 7 % FS

Maximum Load (Ω)

500

Maximum Relative Air Humidity (%)

90

Maximum Voltage Drop Switching Output DC (V)

2.5

Measuring Range (Bar)

-1...16

Measuring range [bar]

-1...16

Media

Compressed Air

Medium Temperature (°C)

-10...60

Medium temperature [°C]

-10...60

Min. process cycle time [ms]

8

Minimum Process Cycle Time (Ms)

8

Model Number

-

MTTF (Years)

167

Number of Analog Outputs

1

Number of Digital Outputs

2

Number of inputs and outputs

Number of digital outputs: 2; Number of analog outputs: 1

Operating Voltage (V)

18...30 DC

Operating voltage [V]

18...30 DC; (to SELV/PELV)

Output Function

Normally Open / Closed

Overload Protection

Yes

Permanent Current Rating of Switching Output DC (Ma)

150

Permanent current rating of switching output DC [mA]

150; (per output)

Power-on Delay Time (S)

1

Power-on delay time [s]

1

Process Connection

Threaded Connection G 1 Internal Thread

Process data analog

8

Process data binary

2

Protection

IP 65; IP 67

Protection Class

III

Pulse Length (S)

0.001...2

Pulse length [s]

0.001...2

Pulse Output

Consumed Quantity Meter

Q (Min)

0, 3 m³ / h

Repeatability

± 1, 5 % MW

Repeatability [% of the final value]

± 0, 2

Required master port class

A

Reset Point Rp (Bar)

-1...15.92

Reset point rP [bar]

-1...15.92

Resolution (Bar)

0.05

Resolution [bar]

0.05

Response Time (S)

0.05

Response time [s]

< 0.1; (dAP = 0, T09)

Reverse Polarity Protection

Yes

SDCI Standard

IEC 61131-9 CDV

Set Point SP (Bar)

-0.92...16

Set point SP [bar]

-0.92...16

Short-circuit Protection

Yes

SIO mode

Yes

Storage Temperature (°C)

-20...85

Storage temperature [°C]

-20...85

Temperature Coefficient (1/K)

± 0, 07 % MW

Temperature coefficient [1/K]

± 0, 07 % MW

Transmission type

COM2 (38, 4 kBaud)

Type of Short-circuit Protection

Yes (Non-latching)

  • Precise measurement of flow, consumption, pressure and medium temperature
  • High accuracy, repeatability and measurement dynamics
  • For detecting compressed air in industrial use
  • With switching output, analog output and pulse output
  • Adjustable to inside pipe diameters

Aug. 15, 2019

PLCs have evolved over the years to become crucial components for driving industrial automation. This post provides insights into the PLCs to help you understand how they work. Remember that you need to pick the right PLC for your system and ensure it is installed by an expert for proper performance.

Read More

 
Aug. 14, 2019

When selecting a PLC for industrial application, it is prudent to consider your system requirements and targeted control. It is also prudent to work with a technical expert and only acquire the PLC that guarantees better results.

Read More

 
Recently Viewed
MA26X1

#706559

Brand

Dodge

Model

MA26X1

$21.53 Each
Free Shipping orders over $100
ATEX4840SS

#97171706

Brand

EXAIR

Model

ATEX4840SS

$3,606.00 Each
Free shipping
21243-4352

#5097907

Brand

Timken

Model

21243-4352

$7,139.82 Each
Free shipping
1003904

#2286886

Brand

Browning

Model

1003904

$156.85 Each
Free shipping
HT8506-30

#852008

Brand

Rexnord

Model

HT8506-30

Call for pricing
UR0006

#96940957

Brand

IFM

Model

UR0006

$28.05 Each
Free Shipping orders over $100
75054545

#2805583

Brand

Dichtomatik

Model

75054545

$6.40 Each
Free Shipping orders over $100
225758

#96656556

Brand

Dodge

Model

225758

$2,934.77 Each
Free shipping