Returnable: Yes
Accuracy (K)
± 0, 5
Accuracy Class
-
Ambient Temperature (°C)
0...60
Ambient temperature [°C]
0...60
Analog Current Output (Ma)
4...20
Analog current output [mA]
4...20; (scalable)
Analog End Point (Bar)
2.2...16
Analog end point [bar]
2.2...16
Analog Start Point (Bar)
-1...12.8
Analog start point [bar]
-1...12.8
Characteristics Deviation (% of The Final Value)
< ± 0, 5
Characteristics deviation [% of the final value]
< ± 0, 5; (BFSL = Best Fit Straight Line)
Communication Interface
IO-Link
Connector
1 x M12; coding: A; Contacts: 4
Current Consumption (Ma)
< 80
Current consumption [mA]
< 80
Damping Process Value dAP (S)
0...5
Damping process value dAP [s]
0...5
Dimensions (mm)
182 x 45.4 x 67.8
Display Range (Bar)
-1...20
Display range [bar]
-1...20
Dynamic Response T05 / T09 (S)
T09 = 0, 5
Dynamic response T05 / T09 [s]
T09 = 0, 5
Electrical Design
PNP / NPN
File Number UL
E174189
Greatest TEMPCO of The Span (% MEW / 10 K)
± 0, 3
Greatest TEMPCO of the span [% MEW / 10 K]
± 0, 3
Greatest TEMPCO of The Zero Point (% MEW / 10 K)
± 0, 1
Greatest TEMPCO of the zero point [% MEW / 10 K]
± 0, 1
Housing
Rectangular
In Steps of (Bar)
0.01
In steps of [bar]
0.01
Inputs
Counter Reset
IO-Link Revision
1.1
MAWP (for Applications According To CRN) (Bar)
9.5
MAWP (for applications according to CRN) [bar]
9.5
Max. load [Ω]
500
Max. relative air humidity [%]
90
Max. voltage drop switching output DC [V]
2.5
Maximum Allowable Error
± 2, 5 % FS
Maximum Load (Ω)
500
Maximum Relative Air Humidity (%)
90
Maximum Voltage Drop Switching Output DC (V)
2.5
Measuring Range (Bar)
-1...16
Measuring range [bar]
-1...16
Media
Compressed Air
Medium Temperature (°C)
-10...60
Medium temperature [°C]
-10...60
Min. process cycle time [ms]
7.2
Minimum Process Cycle Time (Ms)
7.2
Model Number
001TG
MTTF (Years)
183
Number of Analog Outputs
1
Number of Digital Outputs
2
Number of inputs and outputs
Number of digital outputs: 2; Number of analog outputs: 1
Operating Voltage (V)
18...30 DC
Operating voltage [V]
18...30 DC; (to SELV/PELV)
Output Function
Normally Open / Closed
Overload Protection
Yes
Permanent Current Rating of Switching Output DC (Ma)
150
Permanent current rating of switching output DC [mA]
150; (per output)
Power-on Delay Time (S)
1
Power-on delay time [s]
1
Pressure Equipment Directive
Sound Engineering Practice; Can Be Used for Stable Gases Fluid Group 2
Process Connection
threaded connection G 1 / 4 Internal thread DN8
Process data analog
8
Process data binary
2
Protection
IP 65; IP 67
Protection Class
III
Pulse Length (S)
0.01...2
Pulse length [s]
0.01...2
Pulse Output
Consumed Quantity Meter
Q (Min)
0, 05 m³ / h
Repeatability
± (0, 4 % MW + 0, 1 % MEW)
Repeatability [% of the final value]
± 0, 2
Required master port class
A
Reset Point Rp (Bar)
-1...15.92
Reset point rP [bar]
-1...15.92
Resolution (Bar)
0.05
Resolution [bar]
0.05
Response Time (S)
0.05
Response time [s]
< 0.1; (dAP = 0, T09)
Reverse Polarity Protection
Yes
SDCI Standard
IEC 61131-9 CDV
Set Point SP (Bar)
-0.92...16
Set point SP [bar]
-0.92...16
Short-circuit Protection
Yes
SIO mode
Yes
Storage Temperature (°C)
-20...85
Storage temperature [°C]
-20...85
Temperature Coefficient (1/K)
± 0, 07 % MW
Temperature coefficient [1/K]
± 0, 07 % MW
Transmission type
COM2 (38, 4 kBaud)
Type of Short-circuit Protection
Yes (Non-latching)
- Precise measurement of flow, consumption, pressure and medium temperature
- High accuracy, repeatability and measurement dynamics
- For detecting compressed air in industrial use
- Red/green display for clear identification of the acceptable range
- Display can be rotated for optimum alignment
PLCs have evolved over the years to become crucial components for driving industrial automation. This post provides insights into the PLCs to help you understand how they work. Remember that you need to pick the right PLC for your system and ensure it is installed by an expert for proper performance.
Read MoreWhen selecting a PLC for industrial application, it is prudent to consider your system requirements and targeted control. It is also prudent to work with a technical expert and only acquire the PLC that guarantees better results.
Read MoreBrand
Thomson Linear
Model
511P35E1ZC
Brand
Irwin Tools
Model
61611
Brand
Dodge
Model
291315
Brand
Thomson Linear
Model
511P30A2D
Brand
Remke
Model
205A0100J
Brand
Thomson Linear
Model
511U35F3