Returnable: Yes
Accuracy (K)
± 0, 5
Accuracy Class
-
Ambient Temperature (°C)
0...60
Ambient temperature [°C]
0...60
Analog Current Output (Ma)
4...20
Analog current output [mA]
4...20; (scalable)
Communication Interface
IO-Link
Connector
1 x M12; coding: A
Current Consumption (Ma)
< 80
Current consumption [mA]
< 80
Damping Process Value dAP (S)
0...5
Damping process value dAP [s]
0...5
Dimensions (mm)
150 x 45.4 x 71.2
Dimensions [mm]
150 x 45.4 x 71.2
Dynamic Response T05 / T09 (S)
T09 = 0, 5
Dynamic response T05 / T09 [s]
T09 = 0, 5
Electrical Design
PNP / NPN
File Number UL
E174189
Housing
Rectangular
Inputs
Counter Reset
IO-Link Revision
1.1
MAWP (for Applications According To CRN) (Bar)
16
MAWP (for applications according to CRN) [bar]
16
Max. load [Ω]
500
Max. relative air humidity [%]
90
Max. voltage drop switching output DC [V]
2.5
Maximum Allowable Error
± 16, 5 % FS
Maximum Load (Ω)
500
Maximum Relative Air Humidity (%)
90
Maximum Voltage Drop Switching Output DC (V)
2.5
Media
Compressed Air
Medium Temperature (°C)
-10...60
Medium temperature [°C]
-10...60
Min. process cycle time [ms]
5.9
Minimum Process Cycle Time (Ms)
5.9
Model Number
004TG
MTTF (Years)
195
MTTF [years]
195
Number of Analog Outputs
1
Number of Digital Outputs
2
Number of inputs and outputs
Number of digital outputs: 2; Number of analog outputs: 1
Operating Voltage (V)
18...30 DC
Operating voltage [V]
18...30 DC; (to SELV/PELV)
Output Function
Normally Open / Closed
Overload Protection
Yes
Permanent Current Rating of Switching Output DC (Ma)
150
Permanent current rating of switching output DC [mA]
150; (per output)
Power-on Delay Time (S)
1
Power-on delay time [s]
1
Pressure Equipment Directive
Sound Engineering Practice; Can Be Used for Stable Gases Fluid Group 2
Process Connection
threaded connection R 1 / 2 external thread DN15
Process data analog
6
Process data binary
2
Protection
IP 65; IP 67
Protection Class
III
Pulse Length (S)
0.002...2
Pulse length [s]
0.002...2
Pulse Output
Consumed Quantity Meter
Q (Min)
0, 25 m³ / h
Repeatability
± 1, 5 % MW
Required master port class
A
Response Time (S)
< 0.1
Response time [s]
< 0.1; (dAP = 0, T09)
Reverse Polarity Protection
Yes
SDCI Standard
IEC 61131-9 CDV
Short-circuit Protection
Yes
SIO mode
Yes
Storage Temperature (°C)
-20...85
Storage temperature [°C]
-20...85
Temperature Coefficient (1/K)
± 0, 07 % MW
Temperature coefficient [1/K]
± 0, 07 % MW
Transmission type
COM2 (38, 4 kBaud)
Type of Short-circuit Protection
Yes (Non-latching)
- Precise measurement of flow, consumption and medium temperature
- High repeatability and measurement dynamics
- For detecting compressed air in industrial use
- Red/green display for clear identification of the acceptable range
- Display can be rotated for optimum alignment
PLCs have evolved over the years to become crucial components for driving industrial automation. This post provides insights into the PLCs to help you understand how they work. Remember that you need to pick the right PLC for your system and ensure it is installed by an expert for proper performance.
Read MoreWhen selecting a PLC for industrial application, it is prudent to consider your system requirements and targeted control. It is also prudent to work with a technical expert and only acquire the PLC that guarantees better results.
Read MoreBrand
RAB Lighting
Model
GN2LED13NSAD11W
Brand
Cleveland
Model
C81869
Brand
Rexnord
Model
10684615
Brand
Champion
Model
952-7/16
Brand
Walter
Model
9513-03EX
Brand
Timken
Model
24608-0064
Brand
Timken
Model
23022EJW33C3