Stop searching, install MROSupply Smart Check and see our price instantly wherever you browse.

Download Now

Add products to your shopping cart
Know When You’re Overpaying
The MROSupply Chrome Extension instantly alerts you when the part you’re viewing is available for less at MROSupply.
Download Now
We never track your browsing or search history
We never sell your data to third parties
SD6501

Image for Illustration purposes only. Actual product may vary

View in markdown

IFM SD6501 Compressed air meter

MODEL SD6501

BRAND

IFM

SKU

96944166

UOM

each

$1,070.52 Each

Prices are subject to change

FREE SHIPPING ON ORDERS OVER $100

Select Quantity

GET A QUOTE

Returnable: Yes

Accuracy (K)

± 0, 5

Ambient Temperature (°F)

32...140

Ambient temperature [°F]

32...140

Analog Current Output (Ma)

4...20

Analog current output [mA]

4...20; (scalable)

Analog End Point (Psi)

32...232

Analog end point [psi]

32...232

Analog Start Point (Psi)

-15...186

Analog start point [psi]

-15...186

Characteristics Deviation (% of The Final Value)

< ± 0, 5

Characteristics deviation [% of the final value]

< ± 0, 5; (BFSL = Best Fit Straight Line)

Communication Interface

IO-Link

Connector

1 x M12; coding: A; Contacts: 4

Current Consumption (Ma)

< 80

Current consumption [mA]

< 80

Damping Process Value dAP (S)

0...5

Damping process value dAP [s]

0...5

Dimensions (mm)

300 x 45.4 x 71.2

Display Range (Psi)

-15...290

Display range [psi]

-15...290

Dynamic Response T05 / T09 (S)

T09 = 0, 5

Dynamic response T05 / T09 [s]

T09 = 0, 5

Electrical Design

PNP / NPN

File Number UL

E174189

Greatest TEMPCO of The Span (% MEW / 10 K)

± 0, 3

Greatest TEMPCO of the span [% MEW / 10 K]

± 0, 3

Greatest TEMPCO of The Zero Point (% MEW / 10 K)

± 0, 1

Greatest TEMPCO of the zero point [% MEW / 10 K]

± 0, 1

Housing

Rectangular

In Steps of (Psi)

1

In steps of [psi]

1

IO-Link Revision

1.1

MAWP (for Applications According To CRN) (Bar)

9.7

MAWP (for applications according to CRN) [bar]

9.7

Max. load [Ω]

500

Max. relative air humidity [%]

90

Max. voltage drop switching output DC [V]

2.5

Maximum Load (Ω)

500

Maximum Relative Air Humidity (%)

90

Maximum Voltage Drop Switching Output DC (V)

2.5

Measuring Range (Psi)

-15...232

Measuring range [psi]

-15...232

Media

Compressed Air

Medium Temperature (°F)

14...140

Medium temperature [°F]

14...140

Min. burst pressure [psi]

928

Min. process cycle time [ms]

7.2

Minimum Burst Pressure (Psi)

928

Minimum Process Cycle Time (Ms)

7.2

MTTF (Years)

183

MTTF [years]

183

Number of Analog Outputs

1

Number of Digital Outputs

2

Number of inputs and outputs

Number of digital outputs: 2; Number of analog outputs: 1

Operating Voltage (V)

18...30 DC

Operating voltage [V]

18...30 DC; (to SELV/PELV)

Output Function

Normally Open / Closed

Overload Protection

Yes

Permanent Current Rating of Switching Output DC (Ma)

150

Permanent current rating of switching output DC [mA]

150; (per output)

Power-on Delay Time (S)

1

Power-on delay time [s]

1

Pressure Equipment Directive

Sound Engineering Practice; Can Be Used for Stable Gases Fluid Group 2

Pressure Rating (Psi)

232

Pressure rating [psi]

232

Process Connection

threaded connection 1 / 2" NPT external thread DN15

Process data analog

8

Process data binary

2

Protection

IP 65; IP 67

Protection Class

III

Pulse Length (S)

0.002...2

Pulse length [s]

0.002...2

Pulse Output

Consumed Quantity Meter

Repeatability

± (0, 4 % MW + 0, 1 % MEW)

Repeatability [% of the final value]

± 0, 2

Required master port class

A

Reset Point Rp (Psi)

-15...231

Reset point rP [psi]

-15...231

Resolution (Psi)

1

Resolution [psi]

1

Response Time (S)

0.05

Response time [s]

< 0.1; (dAP = 0, T09)

Reverse Polarity Protection

Yes

SDCI Standard

IEC 61131-9 CDV

Set Point SP (Psi)

-13...232

Set point SP [psi]

-13...232

Short-circuit Protection

Yes

SIO mode

Yes

Storage Temperature (°F)

-4...185

Storage temperature [°F]

-4...185

Temperature Coefficient (1/K)

± 0, 07 % MW

Temperature coefficient [1/K]

± 0, 07 % MW

Total Number of Inputs and Outputs

2

Transmission type

COM2 (38, 4 kBaud)

Type of Short-circuit Protection

Yes (Non-latching)

  • Precise measurement of flow, consumption, pressure and medium temperature
  • High accuracy, repeatability and measurement dynamics
  • For detecting compressed air in industrial use
  • Red/green display for clear identification of the acceptable range
  • Display can be rotated for optimum alignment

Aug. 15, 2019

PLCs have evolved over the years to become crucial components for driving industrial automation. This post provides insights into the PLCs to help you understand how they work. Remember that you need to pick the right PLC for your system and ensure it is installed by an expert for proper performance.

Read More

 
Aug. 14, 2019

When selecting a PLC for industrial application, it is prudent to consider your system requirements and targeted control. It is also prudent to work with a technical expert and only acquire the PLC that guarantees better results.

Read More

 
Recently Viewed
9611992727

#6471200

Brand

Flowtrend

Model

9611992727

$11.04 Each
Free Shipping orders over $100
366-90018

#5065253

Brand

Timken

Model

366-90018

Call for pricing
234183

#5008701

Brand

Dodge

Model

234183

$1,373.66 Each
Free shipping
231863

#5006433

Brand

Dodge

Model

231863

$1,117.34 Each
Free shipping
A22-5T200W

#6507835

Brand

RAB Lighting

Model

A22-5T200W

$378.00 Each Add to cart for a lower price
Free shipping
EVF615

#96942300

Brand

IFM

Model

EVF615

$466.29 Each
Free shipping