SD6800

Image for Illustration purposes only. Actual product may vary

View in markdown

IFM SD6800 Industrial gas counter

MODEL SD6800

BRAND

IFM

SKU

96944169

UOM

each

$1,131.57 Each

Prices are subject to change

FREE SHIPPING ON ORDERS OVER $100

Select Quantity

GET A QUOTE

Returnable: Yes

Accuracy (In The Measuring Range)

± (6 % MW + 0, 6 % MEW); at medium temperature 23 °C

Accuracy Class

-

Ambient Temperature (°C)

0...60

Ambient temperature [°C]

0...60

Analog Current Output (Ma)

4...20

Analog current output [mA]

4...20; (scalable)

Analog End Point (Bar)

2.2...16

Analog end point [bar]

2.2...16

Analog Start Point (Bar)

-1...12.8

Analog start point [bar]

-1...12.8

Characteristics Deviation (% of The Final Value)

< ± 0, 5

Characteristics deviation [% of the final value]

< ± 0, 5; (BFSL = Best Fit Straight Line)

Communication Interface

IO-Link

Connector

1 x M12; coding: A; Contacts: 4

Current Consumption (Ma)

< 80

Current consumption [mA]

< 80

Damping Process Value dAP (S)

0...5

Damping process value dAP [s]

0...5

Dimensions (mm)

300 x 45.4 x 71.2

Display Range (Bar)

-1...20

Display range [bar]

-1...20

Dynamic Response T05 / T09 (S)

T09 = 0, 5

Dynamic response T05 / T09 [s]

T09 = 0, 5

Electrical Design

PNP / NPN

File Number UL

E174189

Greatest TEMPCO of The Span (% MEW / 10 K)

± 0, 15

Greatest TEMPCO of the span [% MEW / 10 K]

± 0, 15

Greatest TEMPCO of The Zero Point (% MEW / 10 K)

± 0, 25

Greatest TEMPCO of the zero point [% MEW / 10 K]

± 0, 25

Housing

Rectangular

In Steps of (Bar)

0.01

In steps of [bar]

0.01

Inputs

Counter Reset

IO-Link Revision

1.1

MAWP (for Applications According To CRN) (Bar)

9.7

MAWP (for applications according to CRN) [bar]

9.7

Max. load [Ω]

500

Max. relative air humidity [%]

90

Max. voltage drop switching output DC [V]

2.5

Maximum Allowable Error

± 7 % FS

Maximum Load (Ω)

500

Maximum Relative Air Humidity (%)

90

Maximum Voltage Drop Switching Output DC (V)

2.5

Measuring Range (Bar)

-1...16

Measuring range [bar]

-1...16

Media

Helium

Medium Temperature (°C)

-10...60

Medium temperature [°C]

-10...60

Min. burst pressure [bar]

64

Min. process cycle time [ms]

7.2

Minimum Burst Pressure (Bar)

64

Minimum Process Cycle Time (Ms)

7.2

Model Number

003TG

MTTF (Years)

180

Number of Analog Outputs

1

Number of Digital Outputs

2

Number of inputs and outputs

Number of digital outputs: 2; Number of analog outputs: 1

Operating Voltage (V)

18...30 DC

Operating voltage [V]

18...30 DC; (to SELV/PELV)

Output Function

Normally Open / Closed

Overload Protection

Yes

Permanent Current Rating of Switching Output DC (Ma)

150

Permanent current rating of switching output DC [mA]

150; (per output)

Power-on Delay Time (S)

1

Power-on delay time [s]

1

Pressure Equipment Directive

Sound Engineering Practice; Can Be Used for Stable Gases Fluid Group 2

Process Connection

threaded connection R 1 / 2 external thread DN15

Process data analog

8

Process data binary

2

Protection

IP 65; IP 67

Protection Class

III

Pulse Length (S)

0.002...2

Pulse length [s]

0.002...2

Pulse Output

Consumed Quantity Meter

Q (Min)

0, 1 m³ / h (He)

Repeatability

0, 8 % MW + 0, 2 % MEW

Repeatability [% of the final value]

± 0, 2

Required master port class

A

Reset Point Rp (Bar)

-1...15.92

Reset point rP [bar]

-1...15.92

Resolution (Bar)

0.05

Resolution [bar]

0.05

Response Time (S)

0.05

Response time [s]

< 0.1; (dAP = 0, T09)

Reverse Polarity Protection

Yes

SDCI Standard

IEC 61131-9 CDV

Set Point SP (Bar)

-0.92...16

Set point SP [bar]

-0.92...16

Short-circuit Protection

Yes

SIO mode

Yes

Storage Temperature (°C)

-20...85

Storage temperature [°C]

-20...85

Temperature Coefficient (1/K)

± 0, 07 % MW

Temperature coefficient [1/K]

± 0, 07 % MW

Transmission type

COM2 (38, 4 kBaud)

Type of Short-circuit Protection

Yes (Non-latching)

  • Precise measurement of flow, consumption, pressure and medium temperature
  • High accuracy, repeatability and measurement dynamics
  • For the detection of helium
  • Red/green display for clear identification of the acceptable range
  • Display can be rotated for optimum alignment

Aug. 15, 2019

PLCs have evolved over the years to become crucial components for driving industrial automation. This post provides insights into the PLCs to help you understand how they work. Remember that you need to pick the right PLC for your system and ensure it is installed by an expert for proper performance.

Read More

 
Aug. 14, 2019

When selecting a PLC for industrial application, it is prudent to consider your system requirements and targeted control. It is also prudent to work with a technical expert and only acquire the PLC that guarantees better results.

Read More

 
Recently Viewed
63134158103

#97185111

Brand

FEIN

Model

63134158103

$73.56 Each
Free Shipping orders over $100
24600-6042

#5086899

Brand

Timken

Model

24600-6042

$102.86 Each
Free shipping
21086-2858

#5092559

Brand

Timken

Model

21086-2858

$103.73 Each
Free shipping
31998633080

#97182329

Brand

FEIN

Model

31998633080

$89.76 Each
Free Shipping orders over $100
AK32-1

#2337994

Brand

MasterDrive

Model

AK32-1

$20.36 Each
Free Shipping orders over $100
970W-36

#1963792

Brand

Champion

Model

970W-36

$16.60 Each
Free Shipping orders over $100
ML0487

#2297518

Brand

Morse

Model

ML0487

$4,616.94 Each
Free shipping
CA2SK11G7

#6136242

Brand

Telemecanique

Model

CA2SK11G7

Call for pricing