We never sell your data to third parties
$1,637.90 Each
Prices are subject to change
FREE SHIPPING ON ORDERS OVER $100
Select Quantity
Returnable: Yes
Accuracy (In The Measuring Range)
± (3 % MW + 0, 3 % MEW) / ± (6 % MW + 0, 6 % MEW)
Accuracy Class
-
Ambient Temperature (°C)
0...60
Ambient temperature [°C]
0...60
Analog Current Output (Ma)
4...20
Analog current output [mA]
4...20; (scalable)
Communication Interface
IO-Link
Connector
1 x M12; coding: A
Current Consumption (Ma)
< 110
Current consumption [mA]
< 110
Damping Process Value dAP In Steps (S)
0 - 0, 2 - 0, 4 - 0, 6 - 0, 8 - 1
Damping process value dAP in steps [s]
0 - 0, 2 - 0, 4 - 0, 6 - 0, 8 - 1
Dimensions (mm)
475 x 45 x 88.5
Dimensions [mm]
475 x 45 x 88.5
Display Range (°C)
-12...72
Display range [°C]
-12...72
Display Unit
5 x LED, green (Nl / min, Nm³ / h, Nm / s, Nm³, °C)
Electrical Design
PNP
Function Display
1 x LED, green
In Steps of
0.001 m³
IO-Link Revision
1.1
Max. load [Ω]
500
Max. relative air humidity [%]
90
Max. voltage drop switching output DC [V]
2
Maximum Allowable Error
± 4 % FS
Maximum Load (Ω)
500
Maximum Relative Air Humidity (%)
90
Maximum Voltage Drop Switching Output DC (V)
2
Measured Values
alphanumeric display, 4-digit
Measuring Range (°C)
0...60
Measuring range [°C]
0...60
Media
Compressed Air
Medium Temperature (°C)
0...60
Medium temperature [°C]
0...60
Min. process cycle time [ms]
4.1
Minimum Process Cycle Time (Ms)
4.1
Model Number
002TG
MTTF (Years)
227
MTTF [years]
227
Number of Analog Outputs
1
Number of Digital Outputs
2
Number of inputs and outputs
Number of digital outputs: 2; Number of analog outputs: 1
Operating Voltage (V)
18...30 DC
Operating voltage [V]
18...30 DC; (to SELV/PELV)
Output Function
Normally Open / Closed
Overload Protection
Yes
Pack quantity
1 pcs.
Permanent Current Rating of Switching Output DC (Ma)
250
Permanent current rating of switching output DC [mA]
250; (per output)
Power-on Delay Time (S)
1
Power-on delay time [s]
1
Process Connection
threaded connection R 1 external thread DN25
Process data analog
3
Process data binary
2
Programming
alphanumeric display, 4-digit
Protection
IP 65
Protection Class
III
Pulse Length (S)
0, 02...2
Pulse length [s]
0, 02...2
Pulse Output
Consumed Quantity Meter
Pulse Value
0.003...3000000 m³
Q (Min)
0, 7 m³ / h
Repeatability (% of The Measured Value)
± 1, 5
Repeatability [% of the measured value]
± 1, 5
Required master port class
A
Response Time (S)
0.1
Response time [s]
0.1; (dAP = 0)
Reverse Polarity Protection
Yes
SDCI Standard
IEC 61131-9 CDV
Short-circuit Protection
Yes
SIO mode
Yes
Storage Temperature (°C)
-20...85
Storage temperature [°C]
-20...85
Switching Status
2 x LED, yellow
Total Number of Outputs
2
Transmission type
COM2 (38, 4 kBaud)
Type of Short-circuit Protection
Yes (Non-latching)
- Precise measurement of flow, consumption and medium temperature
- High accuracy, repeatability and measurement dynamics
- For detecting compressed air in industrial use
- With switching output, analog output and pulse output
- Clearly visible numerical display
PLCs have evolved over the years to become crucial components for driving industrial automation. This post provides insights into the PLCs to help you understand how they work. Remember that you need to pick the right PLC for your system and ensure it is installed by an expert for proper performance.
Read MoreWhen selecting a PLC for industrial application, it is prudent to consider your system requirements and targeted control. It is also prudent to work with a technical expert and only acquire the PLC that guarantees better results.
Read MoreBrand
Drillco
Model
20N005CP
Brand
Cle-Line
Model
C43129
Brand
Dormer Pramet
Model
7647831
Brand
Zero-Max
Model
ETP-S45
Brand
M.K. Morse
Model
CTS72
Brand
Berkeley
Model
BVMX33-3-204
Brand
Orbit Industries
Model
STS-50