SD8601

Image for Illustration purposes only. Actual product may vary

View in markdown

IFM SD8601 Industrial gas counter

MODEL SD8601

BRAND

IFM

SKU

96944174

UOM

each

$1,191.74 Each

Prices are subject to change

FREE SHIPPING ON ORDERS OVER $100

Select Quantity

GET A QUOTE

Returnable: Yes

Accuracy (In The Measuring Range)

± (6 % MW + 0, 6 % MEW)

Ambient Temperature (°F)

32...140

Ambient temperature [°F]

32...140

Analog Current Output (Ma)

4...20

Analog current output [mA]

4...20; (scalable)

Analog End Point (Psi)

32...232

Analog end point [psi]

32...232

Analog Start Point (Psi)

-15...186

Analog start point [psi]

-15...186

Characteristics Deviation (% of The Final Value)

< ± 0, 5

Characteristics deviation [% of the final value]

< ± 0, 5; (BFSL = Best Fit Straight Line)

Communication Interface

IO-Link

Connector

1 x M12; coding: A; Contacts: 4

Current Consumption (Ma)

< 80

Current consumption [mA]

< 80

Damping Process Value dAP (S)

0...5

Damping process value dAP [s]

0...5

Dimensions (mm)

475 x 45.4 x 83.1

Display Range (Psi)

-15...290

Display range [psi]

-15...290

Dynamic Response T05 / T09 (S)

T09 = 0, 5

Dynamic response T05 / T09 [s]

T09 = 0, 5

Electrical Design

PNP / NPN

File Number UL

E174189

Greatest TEMPCO of The Span (% MEW / 10 K)

± 0, 3

Greatest TEMPCO of the span [% MEW / 10 K]

± 0, 3

Greatest TEMPCO of The Zero Point (% MEW / 10 K)

± 0, 1

Greatest TEMPCO of the zero point [% MEW / 10 K]

± 0, 1

Housing

Rectangular

In Steps of (Psi)

1

In steps of [psi]

1

Inputs

Counter Reset

IO-Link Revision

1.1

MAWP (for Applications According To CRN) (Bar)

10.5

MAWP (for applications according to CRN) [bar]

10.5

Max. load [Ω]

500

Max. relative air humidity [%]

90

Max. voltage drop switching output DC [V]

2.5

Maximum Load (Ω)

500

Maximum Relative Air Humidity (%)

90

Maximum Voltage Drop Switching Output DC (V)

2.5

Measuring Range (Psi)

-15...232

Measuring range [psi]

-15...232

Media

Argon (Ar); carbon dioxide (CO2); nitrogen (N2); compressed air

Medium Temperature (°F)

14...140

Medium temperature [°F]

14...140

Min. burst pressure [psi]

928

Min. process cycle time [ms]

7.2

Minimum Burst Pressure (Psi)

928

Minimum Process Cycle Time (Ms)

7.2

MTTF (Years)

183

MTTF [years]

183

Number of Analog Outputs

1

Number of Digital Outputs

2

Number of inputs and outputs

Number of digital outputs: 2; Number of analog outputs: 1

Operating Voltage (V)

18...30 DC

Operating voltage [V]

18...30 DC; (to SELV/PELV)

Output Function

Normally Open / Closed

Overload Protection

Yes

Permanent Current Rating of Switching Output DC (Ma)

150

Permanent current rating of switching output DC [mA]

150; (per output)

Power-on Delay Time (S)

1

Power-on delay time [s]

1

Pressure Equipment Directive

Sound Engineering Practice; Can Be Used for Stable Gases Fluid Group 2

Pressure Rating (Psi)

232

Pressure rating [psi]

232

Process Connection

threaded connection 1" NPT external thread DN25

Process data analog

8

Process data binary

2

Protection

IP 65; IP 67

Protection Class

III

Pulse Length (S)

0.007...2

Pulse length [s]

0.007...2

Pulse Output

Consumed Quantity Meter

Repeatability

± (0, 4 % MW + 0, 1 % MEW)

Repeatability [% of the final value]

± 0, 2

Required master port class

A

Reset Point Rp (Psi)

-15...231

Reset point rP [psi]

-15...231

Resolution (Psi)

1

Resolution [psi]

1

Response Time (S)

0.05

Response time [s]

< 0.1; (dAP = 0, T09)

Reverse Polarity Protection

Yes

SDCI Standard

IEC 61131-9 CDV

Set Point SP (Psi)

-13...232

Set point SP [psi]

-13...232

Short-circuit Protection

Yes

SIO mode

Yes

Storage Temperature (°C)

-4...185

Storage temperature [°C]

-4...185

Temperature Coefficient (1/K)

± 0, 07 % MW

Temperature coefficient [1/K]

± 0, 07 % MW

Transmission type

COM2 (38, 4 kBaud)

Type of Short-circuit Protection

Yes (Non-latching)

  • Precise measurement of flow, consumption, pressure and medium temperature
  • High accuracy, repeatability and measurement dynamics
  • For detecting argon (Ar), carbon dioxide (CO2), nitrogen (N2) and compressed air
  • Red/green display for clear identification of the acceptable range
  • Display can be rotated for optimum alignment

Aug. 15, 2019

PLCs have evolved over the years to become crucial components for driving industrial automation. This post provides insights into the PLCs to help you understand how they work. Remember that you need to pick the right PLC for your system and ensure it is installed by an expert for proper performance.

Read More

 
Aug. 14, 2019

When selecting a PLC for industrial application, it is prudent to consider your system requirements and targeted control. It is also prudent to work with a technical expert and only acquire the PLC that guarantees better results.

Read More

 
Recently Viewed
25010-6367

#5085869

Brand

Timken

Model

25010-6367

$245.08 Each
Free shipping
C4100B9WA

#97201726

Brand

Hubbell Wiring

Model

C4100B9WA

$390.67 Each
Free shipping
21702-4507

#5085635

Brand

Timken

Model

21702-4507

$3,126.70 Each
Free shipping
29520-8479

#5083216

Brand

Timken

Model

29520-8479

$1,104.28 Each
Free shipping
203C0250G

#5776026

Brand

Remke

Model

203C0250G

$68.89 Each
Free Shipping orders over $100
NSTU-GTM-30M

#127684

Brand

Dodge

Model

NSTU-GTM-30M

$210.38 Each Add to cart for a lower price
Free shipping
RSSS-512-E

#5781115

Brand

Remke

Model

RSSS-512-E

$581.65 Each
Free shipping