SA4300

Image for Illustration purposes only. Actual product may vary

View in markdown

IFM SA4300 Flow sensor

MODEL SA4300

BRAND

IFM

SKU

96944222

UOM

each

$524.04 Each

Prices are subject to change

FREE SHIPPING ON ORDERS OVER $100

Select Quantity

GET A QUOTE

Returnable: Yes

Accuracy (K)

± 0, 3 / ± 1

Ambient Temperature (°C)

-40...80

Ambient temperature [°C]

-40...80

Analog Current Output (Ma)

4...20

Analog current output [mA]

4...20; (scalable)

Communication Interface

IO-Link

Connector

1 x M12; coding: A; Contacts: gold-plated

Current Consumption (Ma)

< 100

Current consumption [mA]

< 100

Dimensions (mm)

Ø 8 / L = 292

Dimensions [mm]

Ø 8 / L = 292

Display Unit

6 x LED, green (%, m / s, l / min, m³ / h, °C, 10³)

Dynamic Response T05 / T09 (S)

1, 5 (T09)

Dynamic response T05 / T09 [s]

1, 5 (T09); (water; Flow velocity: 0, 3...3 m/s)

Electrical Design

PNP / NPN

Factory Setting / Mode = (REL)

533

File Number UL

E174189

Frequency of The Output (Hz)

0...1000

Frequency of the output [Hz]

0...1000

Greatest Sensitivity (M/S)

30...100

Greatest sensitivity [m/s]

0.04...3

Housing

Tubular

IO-Link Revision

1.1

Material

stainless steel (1.4404 / 316L); PBT-GF20; PBT-GF30

Materials (Wetted Parts)

Stainless Steel (1.4404 / 316L)

MAWP (for Applications According To CRN) (Bar)

50

MAWP (for applications according to CRN) [bar]

50

Max. load [Ω]

350

Max. temperature gradient of medium [K/min]

100

Max. voltage drop switching output DC [V]

2.5

Maximum Load (Ω)

350

Maximum Temperature Gradient of Medium (K/Min)

100

Maximum Voltage Drop Switching Output DC (V)

2.5

Measured Values

alphanumeric display, red / green 4-digit

Measuring Principle

Calorimetric

Measuring Range (°C)

-20...100

Measuring range [°C]

-20...100

Media

Water; Glycol Solutions; Air; Oils

Medium Temperature (°C)

-20...100

Medium temperature [°C]

-20...100

Min. process cycle time [ms]

3

Minimum Process Cycle Time (Ms)

3

Mode = (GAS)

547

MTTF (Years)

180

MTTF [years]

180

Number of Analog Outputs

1

Number of Digital Outputs

2

Number of inputs and outputs

Number of digital outputs: 2; Number of analog outputs: 1

Operating Mode

Relative; Absolutely Liquid; Absolutely Gaseous

Operating Voltage (V)

18...30 DC

Operating voltage [V]

18...30 DC

Output Function

Normally Open / Closed

Overload Protection

Yes

Pack quantity

1 pcs.

Permanent Current Rating of Switching Output DC (Ma)

250

Permanent current rating of switching output DC [mA]

250

Power-on Delay Time (S)

10

Power-on delay time [s]

10

Probe Length L (mm)

200

Probe length L [mm]

200

Process Connection

Clamp fitting Ø 8 mm

Process data analog

2

Process data binary

2

Protection

IP 65; IP 67

Protection Class

III

Repeatability

0, 05 m / s

Required master port class

A

Resolution (°C)

0.2

Resolution [°C]

0.2

Response Time (S)

0.5

Reverse Polarity Protection

Yes

SDCI Standard

IEC 61131-9

Setting Range (M/S)

2...200

Setting range [m/s]

0.04...3

Short-circuit Protection

Yes

SIO mode

Yes

Special feature

Gold-plated contacts

Storage Temperature (°C)

-40...100

Storage temperature [°C]

-40...100

Switching Status

2 x LED, yellow

Temperature drift

± 0, 005 K/°C

Temperature Drift (Cm/S X 1/K)

0, 003 m / s x 1 / K (< 20 °C; > 70 °C)

Temperature drift [cm/s x 1/K]

0, 003 m/s x 1/K (< 20 °C; > 70 °C)

Total Number of Outputs

2

Transmission type

COM2 (38, 4 kBaud)

Type of Short-circuit Protection

Yes (Non-latching)

  • Measurement of flow and temperature at the same time
  • Optimized for water, oils and air
  • Red/green display for clear identification of the acceptable range
  • With switching output, analog signal and IO-Link
  • The process connection can be rotated for optimum alignment

Aug. 15, 2019

PLCs have evolved over the years to become crucial components for driving industrial automation. This post provides insights into the PLCs to help you understand how they work. Remember that you need to pick the right PLC for your system and ensure it is installed by an expert for proper performance.

Read More

 
Aug. 14, 2019

When selecting a PLC for industrial application, it is prudent to consider your system requirements and targeted control. It is also prudent to work with a technical expert and only acquire the PLC that guarantees better results.

Read More

 
Recently Viewed
EM5134RD-BOX

#2849432

Brand

Cooper Wiring

Model

EM5134RD-BOX

$7.46 Each
Free Shipping orders over $100
AY10EAC408

#97175860

Brand

Senco

Model

AY10EAC408

$10.29 Each
Free Shipping orders over $100
25003-5347

#5088845

Brand

Timken

Model

25003-5347

$87.07 Each
Free Shipping orders over $100
31324000392

#97181189

Brand

FEIN

Model

31324000392

$8.02 Each
Free Shipping orders over $100
63734002010

#97186752

Brand

FEIN

Model

63734002010

$65.67 Each
Free Shipping orders over $100
31298330160

#97180800

Brand

FEIN

Model

31298330160

$201.00 Each
Free shipping
24600-4582

#5090564

Brand

Timken

Model

24600-4582

$25.07 Each
Free Shipping orders over $100
RW17BPE

#97179475

Brand

Senco

Model

RW17BPE

$33.72 Each
Free Shipping orders over $100