Accuracy (K)
± 0, 3 / ± 1
Ambient Temperature (°F)
-40...176
Ambient temperature [°F]
-40...176
Analog Current Output (Ma)
4...20
Analog current output [mA]
4...20; (scalable)
Analog End Point (°F)
39...212
Analog end point [°F]
39...212
Analog End Point AEP (Ft/S)
64...328
Analog end point AEP [ft/s]
1.9...9.85
Analog Start Point (°F)
-4...169
Analog start point [°F]
-4...169
Analog Start Point ASP (Ft/S)
0...264
Analog start point ASP [ft/s]
0...7.95
Connector
1 x M12; coding: A; Contacts: gold-plated
Current Consumption (Ma)
< 100
Current consumption [mA]
< 100
Dimensions (mm)
Ø 8 / L = 292
Dimensions [mm]
Ø 8 / L = 292
Display Unit
6 x LED, green (%, fps, gpm, cfm, °F, 10³)
Dynamic Response T05 / T09 (S)
1, 5 (T09)
Dynamic response T05 / T09 [s]
1, 5 (T09); (water; Flow velocity: 1...9, 85 fps)
File Number UL
E174189
Greatest Sensitivity (Ft/S)
6...328
Greatest sensitivity [ft/s]
0.15...9.85
Housing
Tubular
In Steps of (°F)
0.5
In steps of [°F]
0.5
Material
stainless steel (1.4404 / 316L); PBT-GF20; PBT-GF30
Materials (Wetted Parts)
Stainless Steel (1.4404 / 316L)
Max. load [Ω]
350
Max. temperature gradient of medium [K/min]
100
Maximum Load (Ω)
350
Maximum Temperature Gradient of Medium (K/Min)
100
Measured Values
alphanumeric display, red / green 4-digit
Measuring Principle
Calorimetric
Measuring Range (°F)
-4...212
Measuring range [°F]
-4...212
Media
Water; Glycol Solutions; Air; Oils
Medium Temperature (°F)
-4...212
Medium temperature [°F]
-4...212
MTTF (Years)
179
MTTF [years]
179
Number of Analog Outputs
2
Number of inputs and outputs
Number of analog outputs: 2
Operating Mode
Relative; Absolutely Liquid; Absolutely Gaseous
Operating Voltage (V)
18...30 DC
Operating voltage [V]
18...30 DC
Output Signal
Analog Signal
Overload Protection
Yes
Pack quantity
1 pcs.
Power-on Delay Time (S)
10
Power-on delay time [s]
10
Probe Length L (mm)
200
Probe length L [mm]
200
Process Connection
Clamp fitting Ø 8 mm
Protection
IP 65; IP 67
Protection Class
III
Repeatability
0, 05 m / s
Resolution (Ft/S)
2
Resolution [ft/s]
0.05
Resolution [°F]
0.5
Response Time (S)
0.5
Reverse Polarity Protection
Yes
Setting Range (Ft/S)
6...656
Setting range [ft/s]
0.15...9.85
Short-circuit Protection
Yes
Special feature
Gold-plated contacts
Storage Temperature (°F)
-40...212
Storage temperature [°F]
-40...212
Temperature drift
± 0, 003 K/°F
Temperature Drift (Cm/S X 1/K)
0, 01 fps x 1 / K (< 68 °F; > 158 °F)
Temperature drift [cm/s x 1/K]
0, 01 fps x 1/K (< 68 °F; > 158 °F)
Total Number of Outputs
2
Type of Short-circuit Protection
Yes (Non-latching)
- Measurement of flow and temperature at the same time
- Optimized for water, oils and air
- Clearly visible numerical display
- With two scalable analog outputs
- The process connection can be rotated for optimum alignment
PLCs have evolved over the years to become crucial components for driving industrial automation. This post provides insights into the PLCs to help you understand how they work. Remember that you need to pick the right PLC for your system and ensure it is installed by an expert for proper performance.
Read MoreWhen selecting a PLC for industrial application, it is prudent to consider your system requirements and targeted control. It is also prudent to work with a technical expert and only acquire the PLC that guarantees better results.
Read MoreBrand
Timken
Model
25003-1256
Brand
Linn Gear
Model
35AR48
Brand
Drillco
Model
91SE132K
Brand
Dodge
Model
FB-SCEZ-104-PSS MODS
Brand
Ebm-papst
Model
6424
Brand
Timken
Model
FLCT 3/4
Brand
Rexnord
Model
817.30.16