Accuracy (K)
± 0, 3 / ± 1
Ambient Temperature (°C)
-40...80
Ambient temperature [°C]
-40...80
Analog Current Output (Ma)
4...20
Analog current output [mA]
4...20; (scalable)
Communication Interface
IO-Link
Connector
1 x M12; coding: A; Contacts: gold-plated
Current Consumption (Ma)
< 100
Current consumption [mA]
< 100
Dimensions (mm)
Ø 34 / L = 142
Dimensions [mm]
Ø 34 / L = 142
Display Unit
6 x LED, green (%, m / s, l / min, m³ / h, °C, 10³)
Dynamic Response T05 / T09 (S)
1, 5 (T09)
Dynamic response T05 / T09 [s]
1, 5 (T09); (water; Flow velocity: 0, 3...3 m/s)
Electrical Design
PNP / NPN
Factory Setting / Mode = (REL)
533
File Number UL
E174189
Frequency of The Output (Hz)
0...1000
Frequency of the output [Hz]
0...1000
Greatest Sensitivity (M/S)
30...100
Greatest sensitivity [m/s]
0.04...3
Housing
Tubular
Installation Length EL (mm)
45
Installation length EL [mm]
45
IO-Link Revision
1.1
Materials (Wetted Parts)
stainless steel (1.4404 / 316L); Gasket: FKM
MAWP (for Applications According To CRN) (Bar)
100
MAWP (for applications according to CRN) [bar]
100
Max. load [Ω]
350
Max. temperature gradient of medium [K/min]
100
Max. voltage drop switching output DC [V]
2.5
Maximum Load (Ω)
350
Maximum Temperature Gradient of Medium (K/Min)
100
Maximum Voltage Drop Switching Output DC (V)
2.5
Measured Values
alphanumeric display, red / green 4-digit
Measuring Principle
Calorimetric
Measuring Range (°C)
-20...90
Measuring range [°C]
-20...90
Media
Water; Glycol Solutions; Air; Oils
Medium Temperature (°C)
-20...90
Medium temperature [°C]
-20...90
Min. process cycle time [ms]
3
Minimum Process Cycle Time (Ms)
3
Mode = (GAS)
547
MTTF (Years)
132
MTTF [years]
132
Number of Analog Outputs
1
Number of Digital Outputs
2
Number of inputs and outputs
Number of digital outputs: 2; Number of analog outputs: 1
Operating Mode
Relative; Absolutely Liquid; Absolutely Gaseous
Operating Voltage (V)
18...30 DC
Operating voltage [V]
18...30 DC
Output Function
Normally Open / Closed
Overload Protection
Yes
Pack quantity
1 pcs.
Permanent Current Rating of Switching Output DC (Ma)
250
Permanent current rating of switching output DC [mA]
250
Power-on Delay Time (S)
10
Power-on delay time [s]
10
Probe Diameter (mm)
8
Probe diameter [mm]
8
Probe Length L (mm)
45
Probe length L [mm]
45
Process Connection
threaded connection M18 x 1, 5 Internal thread
Process data analog
2
Process data binary
2
Protection
IP 65; IP 67
Protection Class
III
Repeatability
0, 05 m / s
Required master port class
A
Resolution (°C)
0.2
Resolution [°C]
0.2
Response Time (S)
0.5
Reverse Polarity Protection
Yes
SDCI Standard
IEC 61131-9
Setting Range (M/S)
2...200
Setting range [m/s]
0.04...3
Short-circuit Protection
Yes
SIO mode
Yes
Special feature
Gold-plated contacts
Storage Temperature (°C)
-40...100
Storage temperature [°C]
-40...100
Switching Status
2 x LED, yellow
Temperature drift
± 0, 005 K/°C
Temperature Drift (Cm/S X 1/K)
0, 003 m / s x 1 / K (< 20 °C; > 70 °C)
Temperature drift [cm/s x 1/K]
0, 003 m/s x 1/K (< 20 °C; > 70 °C)
Total Number of Outputs
2
Transmission type
COM2 (38, 4 kBaud)
Type of Short-circuit Protection
Yes (Non-latching)
- Measurement of flow and temperature at the same time
- Optimized for water, oils and air
- Red/green display for clear identification of the acceptable range
- With switching output, analog signal and IO-Link
- The process connection can be rotated for optimum alignment
PLCs have evolved over the years to become crucial components for driving industrial automation. This post provides insights into the PLCs to help you understand how they work. Remember that you need to pick the right PLC for your system and ensure it is installed by an expert for proper performance.
Read MoreWhen selecting a PLC for industrial application, it is prudent to consider your system requirements and targeted control. It is also prudent to work with a technical expert and only acquire the PLC that guarantees better results.
Read MoreBrand
Remke
Model
RSSS-625
Brand
EXAIR
Model
902382
Brand
Timken
Model
29519-6908
Brand
Walter
Model
090549
Brand
Walter
Model
15W512
Brand
Te-Co
Model
52813