Accuracy (K)
± 0, 3 / ± 1
Ambient Temperature (°F)
-40...176
Ambient temperature [°F]
-40...176
Analog Current Output (Ma)
4...20
Analog current output [mA]
4...20; (scalable)
Communication Interface
IO-Link
Connector
1 x M12; coding: A; Contacts: gold-plated
Current Consumption (Ma)
< 100
Current consumption [mA]
< 100
Dimensions (mm)
Ø 34 / L = 133.4
Dimensions [mm]
Ø 34 / L = 133.4
Display Unit
6 x LED, green (%, fps, gpm, cfm, °F, 10³)
Dynamic Response T05 / T09 (S)
1, 5 (T09)
Dynamic response T05 / T09 [s]
1, 5 (T09); (water; Flow velocity: 1...9, 85 fps)
Electrical Design
PNP / NPN
Factory Setting / Mode = (REL)
537
File Number UL
E174189
Frequency of The Output (Hz)
0...1000
Frequency of the output [Hz]
0...1000
Greatest Sensitivity (Ft/S)
6...328
Greatest sensitivity [ft/s]
0.15...9.85
Housing
Tubular
Installation Length EL (mm)
26.6
Installation length EL [mm]
26.6
IO-Link Revision
1.1
Materials (Wetted Parts)
Stainless Steel (1.4404 / 316L)
MAWP (for Applications According To CRN) (Bar)
100
MAWP (for applications according to CRN) [bar]
100
Max. load [Ω]
350
Max. temperature gradient of medium [K/min]
100
Max. voltage drop switching output DC [V]
2.5
Maximum Load (Ω)
350
Maximum Temperature Gradient of Medium (K/Min)
100
Maximum Voltage Drop Switching Output DC (V)
2.5
Measured Values
alphanumeric display, red / green 4-digit
Measuring Principle
Calorimetric
Measuring Range (°F)
-4...194
Measuring range [°F]
-4...194
Media
Water; Glycol Solutions; Air; Oils
Medium Temperature (°F)
-4...194
Medium temperature [°F]
-4...194
Min. process cycle time [ms]
3
Minimum Process Cycle Time (Ms)
3
Mode = (GAS)
551
MTTF (Years)
143
MTTF [years]
143
Number of Analog Outputs
1
Number of Digital Outputs
2
Number of inputs and outputs
Number of digital outputs: 2; Number of analog outputs: 1
Operating Mode
Relative; Absolutely Liquid; Absolutely Gaseous
Operating Voltage (V)
18...30 DC
Operating voltage [V]
18...30 DC
Output Function
Normally Open / Closed
Overload Protection
Yes
Pack quantity
1 pcs.
Permanent Current Rating of Switching Output DC (Ma)
250
Permanent current rating of switching output DC [mA]
250
Power-on Delay Time (S)
10
Power-on delay time [s]
10
Probe Diameter (mm)
5
Probe diameter [mm]
5
Probe Length L (mm)
26.6
Probe length L [mm]
26.6
Process Connection
threaded connection 1 / 2" NPT external thread
Process data analog
2
Process data binary
2
Protection
IP 65; IP 67
Protection Class
III
Repeatability
0, 05 m / s
Required master port class
A
Resolution (°F)
0.5
Resolution [°F]
0.5
Response Time (S)
0.5
Reverse Polarity Protection
Yes
SDCI Standard
IEC 61131-9
Setting Range (Ft/S)
6...656
Setting range [ft/s]
0...9.85
Short-circuit Protection
Yes
SIO mode
Yes
Special feature
Gold-plated contacts
Storage Temperature (°F)
-40...212
Storage temperature [°F]
-40...212
Switching Status
2 x LED, yellow
Temperature drift
± 0, 003 K/°F
Temperature Drift (Cm/S X 1/K)
0, 01 fps x 1 / K (< 68 °F; > 158 °F)
Temperature drift [cm/s x 1/K]
0, 01 fps x 1/K (< 68 °F; > 158 °F)
Total Number of Outputs
2
Transmission type
COM2 (38, 4 kBaud)
Type of Short-circuit Protection
Yes (Non-latching)
- Measurement of flow and temperature at the same time
- Optimized for water, oils and air
- Red/green display for clear identification of the acceptable range
- With switching output, analog signal and IO-Link
- The process connection can be rotated for optimum alignment
PLCs have evolved over the years to become crucial components for driving industrial automation. This post provides insights into the PLCs to help you understand how they work. Remember that you need to pick the right PLC for your system and ensure it is installed by an expert for proper performance.
Read MoreWhen selecting a PLC for industrial application, it is prudent to consider your system requirements and targeted control. It is also prudent to work with a technical expert and only acquire the PLC that guarantees better results.
Read MoreBrand
Thomson Linear
Model
HD24B045-0200EXP1MMS
Brand
Berkeley
Model
BVMX10-2-500
Brand
Walter
Model
9700-72
Brand
Dodge
Model
077304
Brand
Dodge
Model
MB45X1/2
Brand
Dodge
Model
295003
Brand
JET Tools
Model
708733