We never sell your data to third parties
$503.36 Each
Prices are subject to change
FREE SHIPPING ON ORDERS OVER $100
Select Quantity
Returnable: Yes
Accuracy (K)
± 0, 3 / ± 1
Ambient Temperature (°F)
-40...176
Ambient temperature [°F]
-40...176
Analog Current Output (Ma)
4...20
Analog current output [mA]
4...20; (scalable)
Analog End Point (°F)
39...212
Analog end point [°F]
39...212
Analog End Point AEP (Ft/S)
64...328
Analog end point AEP [ft/s]
1.9...9.85
Analog Start Point (°F)
-4...169
Analog start point [°F]
-4...169
Analog Start Point ASP (Ft/S)
0...264
Analog start point ASP [ft/s]
0...7.95
Connector
1 x M12; coding: A; Contacts: gold-plated
Current Consumption (Ma)
< 100
Current consumption [mA]
< 100
Dimensions (mm)
Ø 34 / L = 133.4
Dimensions [mm]
Ø 34 / L = 133.4
Display Unit
6 x LED, green (%, fps, gpm, cfm, °F, 10³)
Dynamic Response T05 / T09 (S)
1, 5 (T09)
Dynamic response T05 / T09 [s]
1, 5 (T09); (water; Flow velocity: 1...9, 85 fps)
File Number UL
E174189
Greatest Sensitivity (Ft/S)
6...328
Greatest sensitivity [ft/s]
0.15...9.85
Housing
Tubular
In Steps of (°F)
0.5
In steps of [°F]
0.5
Installation Length EL (mm)
26.6
Installation length EL [mm]
26.6
Materials (Wetted Parts)
Stainless Steel (1.4404 / 316L)
MAWP (for Applications According To CRN) (Bar)
100
MAWP (for applications according to CRN) [bar]
100
Max. load [Ω]
350
Max. temperature gradient of medium [K/min]
100
Maximum Load (Ω)
350
Maximum Temperature Gradient of Medium (K/Min)
100
Measured Values
alphanumeric display, red / green 4-digit
Measuring Principle
Calorimetric
Measuring Range (°F)
-4...194
Measuring range [°F]
-4...194
Media
Water; Glycol Solutions; Air; Oils
Medium Temperature (°F)
-4...194
Medium temperature [°F]
-4...194
MTTF (Years)
180
MTTF [years]
180
Number of Analog Outputs
2
Number of inputs and outputs
Number of analog outputs: 2
Operating Mode
Relative; Absolutely Liquid; Absolutely Gaseous
Operating Voltage (V)
18...30 DC
Operating voltage [V]
18...30 DC
Output Signal
Analog Signal
Overload Protection
Yes
Pack quantity
1 pcs.
Power-on Delay Time (S)
10
Power-on delay time [s]
10
Probe Diameter (mm)
5
Probe diameter [mm]
5
Probe Length L (mm)
26.6
Probe length L [mm]
26.6
Process Connection
threaded connection 1 / 2" NPT external thread
Protection
IP 65; IP 67
Protection Class
III
Repeatability
0, 05 m / s
Resolution (Ft/S)
2
Resolution [ft/s]
0.05
Resolution [°F]
0.5
Response Time (S)
0.5
Reverse Polarity Protection
Yes
Setting Range (Ft/S)
6...656
Setting range [ft/s]
0...9.85
Short-circuit Protection
Yes
Special feature
Gold-plated contacts
Storage Temperature (°F)
-40...212
Storage temperature [°F]
-40...212
Temperature drift
± 0, 003 K/°F
Temperature Drift (Cm/S X 1/K)
0, 01 fps x 1 / K (< 68 °F; > 158 °F)
Temperature drift [cm/s x 1/K]
0, 01 fps x 1/K (< 68 °F; > 158 °F)
Total Number of Outputs
2
Type of Short-circuit Protection
Yes (Non-latching)
- Measurement of flow and temperature at the same time
- Optimized for water, oils and air
- Clearly visible numerical display
- With two scalable analog outputs
- The process connection can be rotated for optimum alignment
PLCs have evolved over the years to become crucial components for driving industrial automation. This post provides insights into the PLCs to help you understand how they work. Remember that you need to pick the right PLC for your system and ensure it is installed by an expert for proper performance.
Read MoreWhen selecting a PLC for industrial application, it is prudent to consider your system requirements and targeted control. It is also prudent to work with a technical expert and only acquire the PLC that guarantees better results.
Read MoreBrand
Thomson Linear
Model
512S35C1ES5
Brand
FEIN
Model
63134158111
Brand
Hubbell Wiring
Model
FB2527
Brand
Walter
Model
059836
Brand
Dodge
Model
042039
Brand
Timken
Model
21158-0771
Brand
Timken
Model
25010-5367
Brand
Timken
Model
24715-6686