Accuracy (in the measuring range)
Medium and operating temperature: +71, 6 °F ± 4K)
Accuracy (K)
3 K (77 °F; Q > 1 l / min)
Accuracy [K]
3 K (77 °F
Ambient Temperature (°F)
32...140
Ambient temperature [°F]
32...140
Analog Current Output (Ma)
4...20
Analog current output [mA]
4...20
Communication Interface
IO-Link
Connector
1 x M12; coding: A; Contacts: 4, gold-plated
Current Consumption (Ma)
< 50
Current consumption [mA]
< 50
Damping for The Analog Output dAA (S)
0...5
Damping for the analog output dAA [s]
0...5
Damping Process Value dAP (S)
0...5
Damping process value dAP [s]
0...5
Display Range (°F)
-26...252
Display range [°F]
-26...252
Display Unit
3 x LED, green
Dp
Pressure Loss
Dynamic Response T05 / T09 (S)
T09 = 120 (Q > 1 l / min)
Dynamic response T05 / T09 [s]
T09 = 120 (Q > 1 l/min)
File Number UL
E174189
Frequency At The End Point FRP (Hz)
10...10000
Frequency at the end point FRP [Hz]
10...10000
Frequency End Point, FEP (°F)
54...212
Frequency end point, FEP [°F]
54...212
Frequency of The Output (Hz)
0...10000
Frequency of the output [Hz]
0...10000
Frequency Start Point, FSP (°F)
14...172
Frequency start point, FSP [°F]
14...172
In Steps of (°F)
2
In steps of [°F]
2
IO-Link Revision
1.1
MAWP (for Applications According To CRN) (Bar)
40
MAWP (for applications according to CRN) [bar]
40
Max. load [Ω]
500
Max. voltage drop switching output DC [V]
2
Maximum Load (Ω)
500
Maximum Voltage Drop Switching Output DC (V)
2
Measured Values
alphanumeric display, red / green 4-digit
Measuring Dynamics
1:50
Measuring Range (°F)
14...212
Measuring range [°F]
14...212
Media
Liquids; Water; Glycol Solutions; Coolants
Medium Temperature (°F)
14...212
Medium temperature [°F]
14...212
Min. process cycle time [ms]
3.2
Minimum Process Cycle Time (Ms)
3.2
MTTF (Years)
145
MTTF [years]
145
Notes
Please note the changed housing design!
Number of Analog Outputs
1
Number of Digital Outputs
2
Number of inputs and outputs
Number of digital outputs: 2; Number of analog outputs: 1
Operating Voltage (V)
18...30 DC
Operating voltage [V]
18...30 DC; (to SELV/PELV)
Output Function
Normally Open / Closed
Overload Protection
Yes
Pack quantity
1 pcs.
Permanent Current Rating of Switching Output DC (Ma)
150; (per output 2 x 200 (...140 °F); 2 x 250 (...104 °F))
Permanent current rating of switching output DC [mA]
150; (per output 2 x 200 (...140 °F); 2 x 250 (...104 °F))
Power-on Delay Time (S)
< 3
Power-on delay time [s]
< 3
Process Connection
threaded connection 3 / 4" NPT Internal thread
Process data analog
2
Process data binary
2
Programming
alphanumeric display, 4-digit
Protection
IP 65; IP 67
Protection Class
III
Q
Volumetric Flow Quantity
Repeatability
± 1 % MEW
Required master port class
A
Reset Point Rp (°F)
14...210
Reset point rP [°F]
14...210
Resolution (°F)
2
Resolution [°F]
2
Response Time (S)
0.01
Response time [s]
0.01
Reverse Polarity Protection
Yes
SDCI Standard
IEC 61131-9 CDV
Set Point SP (°F)
16...212
Set point SP [°F]
16...212
Short-circuit Protection
Yes
SIO mode
Yes
Special feature
Gold-plated contacts
Storage Temperature (°F)
5...176
Storage temperature [°F]
5...176
Switching Cycles (Mechanical)
10 million
Switching Status
2 x LED, yellow
Temperature Drift
0, 9802 °F / K
Total Number of Outputs
2
Transmission type
COM2 (38, 4 kBaud)
- Precise detection of flow in pipes
- Suitable for water, oils and glycol solutions
- Precise linearized analog output
- Robust housing with very high pressure resistance
- Lifespan of more than 10 million pressure cycles
PLCs have evolved over the years to become crucial components for driving industrial automation. This post provides insights into the PLCs to help you understand how they work. Remember that you need to pick the right PLC for your system and ensure it is installed by an expert for proper performance.
Read MoreWhen selecting a PLC for industrial application, it is prudent to consider your system requirements and targeted control. It is also prudent to work with a technical expert and only acquire the PLC that guarantees better results.
Read MoreBrand
FEIN
Model
31324000201
Brand
Meltric
Model
22-14047
Brand
Timken
Model
23550-4665
Brand
Berliss
Model
PA97948
Brand
Timken
Model
29602-4325
Brand
FEIN
Model
63130130010
Brand
Dodge
Model
295808