IFM SBY233 Flow meter with integrated backflow prevention and display
MODEL SBY233
$423.61 Each
Prices are subject to change
FREE SHIPPING ON ORDERS OVER $100
Select Quantity
Returnable: Yes
Accuracy (K)
3 K (25°C; Q > 1 l / min)
Accuracy [K]
3 K (25°C; Q > 1 l/min)
Ambient Temperature (°C)
0...60
Ambient temperature [°C]
0...60
Analog Current Output (Ma)
4...20
Analog current output [mA]
4...20
Communication Interface
IO-Link
Connector
1 x M12; coding: A; Contacts: 4, gold-plated
Current Consumption (Ma)
< 50
Current consumption [mA]
< 50
Damping for The Analog Output dAA (S)
0...5
Damping for the analog output dAA [s]
0...5
Damping Process Value dAP (S)
0...5
Damping process value dAP [s]
0...5
Display Range (°C)
-32...122
Display range [°C]
-32...122
Display Unit
3 x LED, green
Dp
Pressure Loss
Dynamic Response T05 / T09 (S)
T09 = 120 (Q > 1 l / min)
Dynamic response T05 / T09 [s]
T09 = 120 (Q > 1 l/min)
File Number UL
E174189
Frequency At The End Point FRP (Hz)
10...10000
Frequency at the end point FRP [Hz]
10...10000
Frequency End Point, FEP (°C)
12...100
Frequency end point, FEP [°C]
12...100
Frequency of The Output (Hz)
0...10000
Frequency of the output [Hz]
0...10000
Frequency Start Point, FSP (°C)
-10...78
Frequency start point, FSP [°C]
-10...78
In Steps of (°C)
1
In steps of [°C]
1
IO-Link Revision
1.1
MAWP (for Applications According To CRN) (Bar)
40
MAWP (for applications according to CRN) [bar]
40
Max. load [Ω]
500
Max. voltage drop switching output DC [V]
2
Maximum Load (Ω)
500
Maximum Voltage Drop Switching Output DC (V)
2
Measured Values
alphanumeric display, red / green 4-digit
Measuring Dynamics
1:50
Measuring Range (°C)
-10...100
Measuring range [°C]
-10...100
Media
Liquids; Water; Glycol Solutions; Coolants
Medium Temperature (°C)
-10...100
Medium temperature [°C]
-10...100
Min. process cycle time [ms]
3.2
Minimum Process Cycle Time (Ms)
3.2
MTTF (Years)
145
MTTF [years]
145
Notes
Please note the changed housing design!
Number of Analog Outputs
1
Number of Digital Outputs
2
Number of inputs and outputs
Number of digital outputs: 2; Number of analog outputs: 1
Operating Voltage (V)
18...30 DC
Operating voltage [V]
18...30 DC; (to SELV/PELV)
Output Function
Normally Open / Closed
Overload Protection
Yes
Pack quantity
1 pcs.
Permanent Current Rating of Switching Output DC (Ma)
150; (per output 2 x 200 (...60 °C); 2 x 250 (...40 °C))
Permanent current rating of switching output DC [mA]
150; (per output 2 x 200 (...60 °C); 2 x 250 (...40 °C))
Power-on Delay Time (S)
< 3
Power-on delay time [s]
< 3
Process Connection
Threaded Connection Rp 3 / 4 Internal Thread
Process data analog
2
Process data binary
2
Programming
alphanumeric display, 4-digit
Protection
IP 65; IP 67
Protection Class
III
Q
Volumetric Flow Quantity
Repeatability
± 1 % MEW
Required master port class
A
Reset Point Rp (°C)
-10...99
Reset point rP [°C]
-10...99
Resolution (°C)
1
Resolution [°C]
1
Response Time (S)
0.01
Response time [s]
0.01
Reverse Polarity Protection
Yes
SDCI Standard
IEC 61131-9 CDV
Set Point SP (°C)
-9...100
Set point SP [°C]
-9...100
Short-circuit Protection
Yes
SIO mode
Yes
Special feature
Gold-plated contacts
Storage Temperature (°C)
-15...80
Storage temperature [°C]
-15...80
Switching Cycles (Mechanical)
10 million
Switching Status
2 x LED, yellow
Temperature Drift
0, 029 °C / K
Total Number of Outputs
2
Transmission type
COM2 (38, 4 kBaud)
- Flow meter with integrated backflow prevention and display
- Operating voltage 18...30 DC
- (according to EN 50178 SELV/PELV) V
- M12 Connector
- Gold-plated contacts
- for industrial applications
The industrial sensor is an industrial device category used to serve its stated function within industrial automation equipment. It is incorporated into equipment arrangements where that general function is needed. The configuration details in the list identify this cataloged item and should be considered with the product technical documentation and applicable machine requirements. Catalog number SBY233 distinguishes this item in the equipment record. This paragraph provides general device context only; product-specific technical details are limited to the listed source information.
PLCs have evolved over the years to become crucial components for driving industrial automation. This post provides insights into the PLCs to help you understand how they work. Remember that you need to pick the right PLC for your system and ensure it is installed by an expert for proper performance.
Read MoreWhen selecting a PLC for industrial application, it is prudent to consider your system requirements and targeted control. It is also prudent to work with a technical expert and only acquire the PLC that guarantees better results.
Read MoreBrand
Flowtrend
Model
H76943
Brand
SealMaster
Model
SCHB-320
Brand
Martin Sprocket
Model
D08B72
Brand
Browning
Model
H6017X 1 5/8
Brand
Siemens Controls
Model
3NA3824
Brand
Thomson Linear
Model
K2RAG20-24V-SNL
Brand
Timken
Model
25006-5092
Brand
Thomson Linear
Model
HD12B100-0150EXP2MMS