We never sell your data to third parties
$1,142.24 Each
Prices are subject to change
FREE SHIPPING ON ORDERS OVER $100
Select Quantity
Returnable: Yes
Accuracy (In The Measuring Range)
± (2 % MW + 0, 5 % MEW)
Accuracy [K]
± 2, 5 (Q > 5 l/min)
Accuracy Class
-
Ambient Temperature (°C)
-10...60
Ambient temperature [°C]
-10...60
Analog Current Output (Ma)
4...20
Analog current output [mA]
4...20; (scalable)
Analog End Point (°C)
0...80
Analog end point [°C]
0...80
Analog Start Point (°C)
-20...60
Analog start point [°C]
-20...60
Analog Voltage Output (V)
0...10
Analog voltage output [V]
0...10; (scalable)
Connector
1 x M12; coding: A; Contacts: gold-plated
Current Consumption (Ma)
95
Current consumption [mA]
95; (24 V)
Damping Process Value dAP (S)
0...5
Damping process value dAP [s]
0...5
Delay Time Programmable Ds, Dr (S)
0...50
Delay time programmable dS, dr [s]
0...50
Dimensions (mm)
Ø 54 / L = 110
Dimensions [mm]
Ø 54 / L = 110
DIN IEC 68-2-27
20 g (11 ms)
DIN IEC 68-2-6
5 g (10...2000 Hz)
Display Unit
6 x LED, green (l / min, m³ / h, l, m³, 10³, °C)
Dp
Pressure Loss
Dynamic Response T05 / T09 (S)
T09 = 30 (Q > 5 l / min)
Dynamic response T05 / T09 [s]
T09 = 30 (Q > 5 l/min)
Electrical Design
PNP / NPN
Housing
Tubular
In Steps of (°C)
0.2
In steps of [°C]
0.2
Inlet Pipe Length
5 x DN
Inputs
Counter Reset
Material
stainless steel (1.4404 / 316L); PBT-GF20; PC; EPDM / X
Materials (Wetted Parts)
stainless steel (1.4404 / 316L); PEEK; EPDM / X
Max. load [Ω]
500
Max. voltage drop switching output DC [V]
2
Maximum Allowable Error
± 2, 5 % FS
Maximum Load (Ω)
500
Maximum Voltage Drop Switching Output DC (V)
2
Measured Values
alphanumeric display, 4-digit
Measuring Principle
Magnetic-inductive
Measuring Range (°C)
-20...80
Measuring range [°C]
-20...80
Media
Conductive Liquids; Water; Water-based Media
Medium Temperature (°C)
-10...70
Medium temperature [°C]
-10...70
Min. insulation resistance [MΩ]
100; (500 V DC)
Min. load resistance [Ω]
2000
Minimum Insulation Resistance (MΩ)
100
Minimum Load Resistance (Ω)
2000
Model Number
009MI
MTTF (Years)
130
MTTF [years]
130
Number of Analog Outputs
1
Number of Digital Outputs
2
Number of inputs and outputs
Number of digital outputs: 2; Number of analog outputs: 1
Operating Voltage (V)
18...30 DC
Operating voltage [V]
18...30 DC; (to SELV/PELV)
Outlet Pipe Length
2 x DN
Output Function
Normally Open / Closed
Output Signal
Switching Signal; Analog Signal; Pulse Signal
Overload Protection
Yes
Pack quantity
1 pcs.
Permanent Current Rating of Switching Output DC (Ma)
200
Permanent current rating of switching output DC [mA]
200
Power-on Delay Time (S)
5
Power-on delay time [s]
5
Process Connection
threaded connection G 1 external thread DN25 flat seal
Programming
alphanumeric display, 4-digit
Protection
IP 67
Protection Class
III
Pulse Length (S)
0, 025...2
Pulse length [s]
0, 025...2
Pulse Output
Flow Rate Meter
Pulse Value
0.1 l...100 000 m³
Q (Min)
0, 01 m³ / h
Repeatability
± 0, 2% MEW
Reset Point Rp (°C)
-19.6...79.6
Reset point rP [°C]
-19.6...79.6
Resolution (°C)
0.2
Resolution [°C]
0.2
Response Time (S)
0.15
Response time [s]
0.15; (dAP = 0)
Reverse Polarity Protection
Yes
Set Point SP (°C)
-19.2...80
Set point SP [°C]
-19.2...80
Short-circuit Protection
Yes
Special feature
Gold-plated contacts
Storage Temperature (°C)
-25...80
Storage temperature [°C]
-25...80
Switching Status
2 x LED, yellow
Total Number of Outputs
2
Type of Short-circuit Protection
Yes (Non-latching)
- Operating voltage 18...30 DC
- (according to EN 50178 SELV/PELV) V
- PNP/NPN
- M12 Connector
- Gold-plated contacts
- empty pipe detection, totaliser function, for industrial applications
The industrial sensor is an industrial device category used to serve its stated function within industrial automation equipment. It is incorporated into equipment arrangements where that general function is needed. The configuration details in the list identify this cataloged item and should be considered with the product technical documentation and applicable machine requirements. Catalog number SM0505 distinguishes this item in the equipment record. This paragraph provides general device context only; product-specific technical details are limited to the listed source information.
PLCs have evolved over the years to become crucial components for driving industrial automation. This post provides insights into the PLCs to help you understand how they work. Remember that you need to pick the right PLC for your system and ensure it is installed by an expert for proper performance.
Read MoreWhen selecting a PLC for industrial application, it is prudent to consider your system requirements and targeted control. It is also prudent to work with a technical expert and only acquire the PLC that guarantees better results.
Read MoreBrand
SKF Seals
Model
30003
Brand
Timken
Model
29602-6967
Brand
Berkeley
Model
BVM64-3-1-300
Brand
Timken
Model
21086-2276
Brand
RAB Lighting
Model
ALEDXL4TWMB
Brand
FEIN
Model
63135191133
Brand
Senco
Model
AY10EAC477