Accuracy (In The Measuring Range)
± (2 % MW + 0, 5 % MEW)
Accuracy [K]
± 2, 5 (Q > 0, 5 l/min)
Accuracy Class
-
Ambient Temperature (°C)
-10...60
Ambient temperature [°C]
-10...60
Analog Current Output (Ma)
4...20
Analog current output [mA]
4...20; (scalable)
Analog End Point (°C)
0...80
Analog end point [°C]
0...80
Analog End Point AEP (Ml/Min)
600...3000
Analog end point AEP [ml/min]
600...3000
Analog Start Point (°C)
-20...60
Analog start point [°C]
-20...60
Analog Start Point ASP (Ml/Min)
0...2400
Analog start point ASP [ml/min]
0...2400
Analog Voltage Output (V)
0...10
Analog voltage output [V]
0...10; (scalable)
Communication Interface
IO-Link
Connector
1 x M12; coding: A; Contacts: gold-plated
Current Consumption (Ma)
< 80
Current consumption [mA]
< 80
Damping Process Value dAP (S)
0...5
Damping process value dAP [s]
0...5
Delay Time Programmable Ds, Dr (S)
0...50
Delay time programmable dS, dr [s]
0...50
Dimensions (mm)
Ø 54 / L = 110
Dimensions [mm]
Ø 54 / L = 110
DIN IEC 68-2-27
20 g (11 ms)
DIN IEC 68-2-6
5 g (10...2000 Hz)
Display Range (Ml/Min)
-1999...3600
Display range [ml/min]
-1999...3600
Display Unit
6 x LED, green (ml / min, l / h, l, m³, °C, 10³)
Dp
Pressure Loss
Dynamic Response T05 / T09 (S)
T09 = 40 (Q > 1 l / min)
Dynamic response T05 / T09 [s]
T09 = 40 (Q > 1 l/min)
Electrical Design
PNP / NPN
In Steps of (°C)
0.2
In steps of [°C]
0.2
Inlet Pipe Length
3 x DN
Inputs
Counter Reset
Installation
Connection to pipe by means of an adapter
IO-Link Revision
1.1
Low Flow Cut-off LFC (Ml/Min)
< 60
Low flow cut-off LFC [ml/min]
< 60
Material
stainless steel (1.4404 / 316L); PBT-GF20; PC; FKM; TPE
Materials (Wetted Parts)
stainless steel (1.4404 / 316L); PEEK; FKM
Max. load [Ω]
500
Max. voltage drop switching output DC [V]
2
Maximum Allowable Error
± 2, 5 % FS
Maximum Load (Ω)
500
Maximum Voltage Drop Switching Output DC (V)
2
Measured Values
alphanumeric display, 4-digit
Measuring Principle
Magnetic-inductive
Measuring Range (°C)
-20...80
Measuring range [°C]
-20...80
Media
Conductive Liquids; Water; Water-based Media
Medium Temperature (°C)
0...60
Medium temperature [°C]
0...60
Min. load resistance [Ω]
2000
Min. process cycle time [ms]
5
Minimum Load Resistance (Ω)
2000
Minimum Process Cycle Time (Ms)
5
Model Number
007MI
MTTF (Years)
144
MTTF [years]
144
Number of Analog Outputs
1
Number of Digital Outputs
2
Number of inputs and outputs
Number of digital outputs: 2; Number of analog outputs: 1
Operating Voltage (V)
18...30 DC
Operating voltage [V]
18...30 DC; (to SELV/PELV)
Outlet Pipe Length
1 x DN
Output Function
Normally Open / Closed
Overload Protection
Yes
Pack quantity
1 pcs.
Permanent Current Rating of Switching Output DC (Ma)
200
Permanent current rating of switching output DC [mA]
200
Power-on Delay Time (S)
5
Power-on delay time [s]
5
Process Connection
threaded connection G 1 / 4 external thread DN6 flat seal
Process data analog
3
Process data binary
2
Programming
alphanumeric display, 4-digit
Protection
IP 67
Protection Class
III
Pulse Length (S)
0, 008...2
Pulse length [s]
0, 008...2
Pulse Output
Flow Rate Meter
Pulse Value
1...3000 ml
Q (Min)
0, 0003 m³ / h
Repeatability
± 0, 2% MEW
Required master port class
A
Reset Point Rp (Ml/Min)
5...2984
Reset point rP [ml/min]
5...2984
Reset point rP [°C]
-19.6...79.6
Resolution (Ml/Min)
1
Resolution [ml/min]
1
Resolution [°C]
0.2
Response Time (S)
0.15
Response time [s]
0.15; (dAP = 0, T19)
Reverse Polarity Protection
Yes
SDCI Standard
IEC 61131-9
Set Point SP (Ml/Min)
20...3000
Set point SP [ml/min]
20...3000
Set point SP [°C]
-19.2...80
Short-circuit Protection
Yes
SIO mode
Yes
Special feature
Gold-plated contacts
Storage Temperature (°C)
-25...80
Storage temperature [°C]
-25...80
Switching Status
2 x LED, yellow
Total Number of Outputs
2
Transmission type
COM2 (38, 4 kBaud)
Type of Short-circuit Protection
Yes (Non-latching)
- Precise measurement of flow, consumption and medium temperature
- High accuracy, repeatability and measurement dynamics
- With switching output, analog output and pulse output
- Clearly visible numerical display
PLCs have evolved over the years to become crucial components for driving industrial automation. This post provides insights into the PLCs to help you understand how they work. Remember that you need to pick the right PLC for your system and ensure it is installed by an expert for proper performance.
Read MoreWhen selecting a PLC for industrial application, it is prudent to consider your system requirements and targeted control. It is also prudent to work with a technical expert and only acquire the PLC that guarantees better results.
Read MoreBrand
Regal Cutting Tools
Model
092421PS
Brand
TB Woods
Model
4430V780
Brand
Remke
Model
503K0265AB
Brand
Orbit Industries
Model
PC-1T
Brand
Cle-Line
Model
C67226
Brand
MRO Supply
Model
40-1OL
Brand
JET Tools
Model
577102K
Brand
NAE
Model
33-100-26-U