SM6000

Image for Illustration purposes only. Actual product may vary

View in markdown

IFM SM6000 Magnetic-inductive flow meter

MODEL SM6000

BRAND

IFM

SKU

96944333

UOM

each

$829.73 Each

Prices are subject to change

FREE SHIPPING ON ORDERS OVER $100

Select Quantity

GET A QUOTE

Returnable: Yes

Accuracy (In The Measuring Range)

± (0, 8 % MW + 0, 5 % MEW)

Accuracy [K]

± 2, 5 (Q > 1 l/min)

Accuracy Class

-

Ambient Temperature (°C)

-10...60

Ambient temperature [°C]

-10...60

Analog Current Output (Ma)

4...20

Analog current output [mA]

4...20; (scalable)

Analog End Point (°C)

0...80

Analog end point [°C]

0...80

Analog Start Point (°C)

-20...60

Analog start point [°C]

-20...60

Analog Voltage Output (V)

0...10

Analog voltage output [V]

0...10; (scalable)

Communication Interface

IO-Link

Connector

1 x M12; coding: A; Contacts: gold-plated

Current Consumption (Ma)

95

Current consumption [mA]

95; (24 V)

Damping Process Value dAP (S)

0...5

Damping process value dAP [s]

0...5

Delay Time Programmable Ds, Dr (S)

0...50

Delay time programmable dS, dr [s]

0...50

Dimensions (mm)

Ø 54 / L = 110

Dimensions [mm]

Ø 54 / L = 110

DIN IEC 68-2-27

20 g (11 ms)

DIN IEC 68-2-6

5 g (10...2000 Hz)

Display Unit

6 x LED, green (l / min, m³ / h, l, m³, 10³, °C)

Dp

Pressure Loss

Dynamic Response T05 / T09 (S)

T09 = 20 (Q > 1 l / min)

Dynamic response T05 / T09 [s]

T09 = 20 (Q > 1 l/min)

Electrical Design

PNP / NPN

Housing

Tubular

In Steps of (°C)

0.2

In steps of [°C]

0.2

Inlet Pipe Length

3 x DN

Inputs

Counter Reset

Installation

Connection to pipe by means of an adapter

IO-Link Revision

1.1

Material

stainless steel (1.4404 / 316L); PBT-GF20; PC; FKM; TPE

Materials (Wetted Parts)

stainless steel (1.4404 / 316L); PEEK; FKM

Max. load [Ω]

500

Max. voltage drop switching output DC [V]

2

Maximum Allowable Error

± 1, 5 % FS

Maximum Load (Ω)

500

Maximum Voltage Drop Switching Output DC (V)

2

Measured Values

alphanumeric display, 4-digit

Measuring Principle

Magnetic-inductive

Measuring Range (°C)

-20...80

Measuring range [°C]

-20...80

Media

Conductive Liquids; Water; Water-based Media

Medium Temperature (°C)

-10...70

Medium temperature [°C]

-10...70

Min. insulation resistance [MΩ]

100; (500 V DC)

Min. load resistance [Ω]

2000

Min. process cycle time [ms]

5

Minimum Insulation Resistance (MΩ)

100

Minimum Load Resistance (Ω)

2000

Minimum Process Cycle Time (Ms)

5

Model Number

001MI

MTTF (Years)

162

MTTF [years]

162

Number of Analog Outputs

1

Number of Digital Outputs

2

Number of inputs and outputs

Number of digital outputs: 2; Number of analog outputs: 1

Operating Voltage (V)

18...30 DC

Operating voltage [V]

18...30 DC; (to SELV/PELV)

Outlet Pipe Length

1 x DN

Output Function

Normally Open / Closed

Overload Protection

Yes

Pack quantity

1 pcs.

Permanent Current Rating of Switching Output DC (Ma)

200

Permanent current rating of switching output DC [mA]

200

Power-on Delay Time (S)

5

Power-on delay time [s]

5

Process Connection

threaded connection G 1 / 2 external thread DN15 flat seal

Process data analog

3

Process data binary

2

Programming

alphanumeric display, 4-digit

Protection

IP 67

Protection Class

III

Pulse Length (S)

0, 01...2

Pulse length [s]

0, 01...2

Pulse Output

Flow Rate Meter

Pulse Value

0.00001...30 000 m³

Q (Min)

0, 005 m³ / h

Repeatability

± 0, 2% MEW

Required master port class

A

Reset Point Rp (°C)

-19.6...79.6

Reset point rP [°C]

-19.6...79.6

Resolution (°C)

0.2

Resolution [°C]

0.2

Response Time (S)

0.15

Response time [s]

0.15; (dAP = 0, T19)

Reverse Polarity Protection

Yes

SDCI Standard

IEC 61131-9

Set Point SP (°C)

-19.2...80

Set point SP [°C]

-19.2...80

Short-circuit Protection

Yes

SIO mode

Yes

Special feature

Gold-plated contacts

Storage Temperature (°C)

-25...80

Storage temperature [°C]

-25...80

Switching Status

2 x LED, yellow

Total Number of Outputs

2

Transmission type

COM2 (38, 4 kBaud)

Type of Short-circuit Protection

Yes (Non-latching)

  • Precise measurement of flow, consumption and medium temperature
  • High accuracy, repeatability and measurement dynamics
  • With switching output, analog output and pulse output
  • Clearly visible numerical display

Aug. 15, 2019

PLCs have evolved over the years to become crucial components for driving industrial automation. This post provides insights into the PLCs to help you understand how they work. Remember that you need to pick the right PLC for your system and ensure it is installed by an expert for proper performance.

Read More

 
Aug. 14, 2019

When selecting a PLC for industrial application, it is prudent to consider your system requirements and targeted control. It is also prudent to work with a technical expert and only acquire the PLC that guarantees better results.

Read More

 
Recently Viewed
E43227

#96941143

Brand

IFM

Model

E43227

$56.21 Each
Free Shipping orders over $100
HT8507-12

#521271

Brand

Rexnord

Model

HT8507-12

Call for pricing
21086-3945

#5089447

Brand

Timken

Model

21086-3945

$343.51 Each
Free shipping
526490

#2574232

Brand

SKF Seals

Model

526490

$771.77 Each
Free shipping
40B48F-1C

#394616

Brand

U.S.Tsubaki

Model

40B48F-1C

$78.43 Each
Free Shipping orders over $100
12005-010

#6244772

Brand

Balax

Model

12005-010

$22.50 Each