IFM SM6601 SMN12GGXFRKG/US-100 Magnetic-inductive flow meter
MODEL SM6601
$829.73 Each
Prices are subject to change
FREE SHIPPING ON ORDERS OVER $100
Select Quantity
Typically Ships in: 1 day
Returnable: Yes
Accuracy (In The Measuring Range)
± (0, 8 % MW + 0, 5 % MEW)
Accuracy [K]
± 2, 5 (Q > 0, 26 gpm)
Ambient Temperature (°F)
14...140
Ambient temperature [°F]
14...140
Analog Current Output (Ma)
4...20
Analog current output [mA]
4...20; (scalable)
Analog End Point (°F)
31.5...176
Analog end point [°F]
31.5...176
Analog Start Point (°F)
-4...140.5
Analog start point [°F]
-4...140.5
Analog Voltage Output (V)
0...10
Analog voltage output [V]
0...10; (scalable)
Communication Interface
IO-Link
Connector
1 x M12; coding: A; Contacts: gold-plated
Current Consumption (Ma)
95
Current consumption [mA]
95; (24 V)
Damping Process Value dAP (S)
0...5
Damping process value dAP [s]
0...5
Delay Time Programmable Ds, Dr (S)
0...50
Delay time programmable dS, dr [s]
0...50
Dimensions (mm)
Ø 54 / L = 110
Dimensions [mm]
Ø 54 / L = 110
Display Unit
6 x LED, green (gpm, gph, gal, °F, 10³, 1000 x 10³)
Dp
Pressure Loss
Dynamic Response T05 / T09 (S)
T09 = 20 (Q > 0, 26 gpm)
Dynamic response T05 / T09 [s]
T09 = 20 (Q > 0, 26 gpm)
Electrical Design
PNP / NPN
Housing
Tubular
In Steps of (°F)
0.5
In steps of [°F]
0.5
Inlet Pipe Length
3 x DN
Inputs
Counter Reset
IO-Link Revision
1.1
Material
stainless steel (1.4404 / 316L); PBT-GF20; PC; FKM; TPE
Materials (Wetted Parts)
stainless steel (1.4404 / 316L); PEEK; FKM
Max. load [Ω]
500
Max. voltage drop switching output DC [V]
2
Maximum Load (Ω)
500
Maximum Voltage Drop Switching Output DC (V)
2
Measured Values
alphanumeric display, 4-digit
Measuring Principle
Magnetic-inductive
Measuring Range (°F)
-4...176
Measuring range [°F]
-4...176
Media
Conductive Liquids; Water; Water-based Media
Medium Temperature (°F)
14...158
Medium temperature [°F]
14...158
Min. insulation resistance [MΩ]
100; (500 V DC)
Min. load resistance [Ω]
2000
Min. process cycle time [ms]
5
Minimum Insulation Resistance (MΩ)
100
Minimum Load Resistance (Ω)
2000
Minimum Process Cycle Time (Ms)
5
MTTF (Years)
145
MTTF [years]
145
Number of Analog Outputs
1
Number of Digital Outputs
2
Number of inputs and outputs
Number of digital outputs: 2; Number of analog outputs: 1
Operating Voltage (V)
18...30 DC
Operating voltage [V]
18...30 DC; (to SELV/PELV)
Outlet Pipe Length
1 x DN
Output Function
Normally Open / Closed
Overload Protection
Yes
Pack quantity
1 pcs.
Permanent Current Rating of Switching Output DC (Ma)
200
Permanent current rating of switching output DC [mA]
200
Power-on Delay Time (S)
5
Power-on delay time [s]
5
Process Connection
threaded connection 1 / 2" NPT Internal thread DN15
Process data analog
3
Process data binary
2
Programming
alphanumeric display, 4-digit
Protection
IP 67
Protection Class
III
Pulse Length (S)
0, 01...2
Pulse length [s]
0, 01...2
Pulse Output
Flow Rate Meter
Pulse Value
0.01...30 000 000 gal
Q
Volumetric Flow Quantity
Repeatability
± 0, 2% MEW
Required master port class
A
Reset Point Rp (°F)
-3.5...175
Reset point rP [°F]
-3.5...175
Resolution (°F)
0.1
Resolution [°F]
0.1
Response Time (S)
0.15
Response time [s]
0.15; (dAP = 0, T19)
Reverse Polarity Protection
Yes
SDCI Standard
IEC 61131-9
Set Point SP (°F)
-2.5...176
Set point SP [°F]
-2.5...176
Short-circuit Protection
Yes
SIO mode
Yes
Special feature
Gold-plated contacts
Storage Temperature (°F)
-13...176
Storage temperature [°F]
-13...176
Switching Status
2 x LED, yellow
Total Number of Outputs
2
Transmission type
COM2 (38, 4 kBaud)
Type of Short-circuit Protection
Yes (Non-latching)
- Precise measurement of flow, consumption and medium temperature
- High accuracy, repeatability and measurement dynamics
- With switching output, analog output and pulse output
- Clearly visible numerical display
PLCs have evolved over the years to become crucial components for driving industrial automation. This post provides insights into the PLCs to help you understand how they work. Remember that you need to pick the right PLC for your system and ensure it is installed by an expert for proper performance.
Read MoreWhen selecting a PLC for industrial application, it is prudent to consider your system requirements and targeted control. It is also prudent to work with a technical expert and only acquire the PLC that guarantees better results.
Read MoreBrand
Hanson
Model
21521
Brand
Enerpac
Model
RLP1202
Brand
Wiegmann
Model
HW-J121005CHQRW