Accuracy (In The Measuring Range)
± (0, 8 % MW + 0, 2 % MEW)
Accuracy [K]
± 2, 5 (Q > 5 % MEW)
Ambient Temperature (°F)
-4...140
Ambient temperature [°F]
-4...140
Analog Current Output (Ma)
4...20
Analog current output [mA]
4...20; (scalable)
Analog End Point (°F)
35.6...194
Analog end point [°F]
35.6...194
Analog Start Point (°F)
-4...154.4
Analog start point [°F]
-4...154.4
Communication Interface
IO-Link
Connector
1 x M12; coding: A; Contacts: gold-plated
Current Consumption (Ma)
< 80
Current consumption [mA]
< 80
Damping Process Value dAP (S)
0...5
Damping process value dAP [s]
0...5
Dimensions (mm)
110 x 48 x 73
Dimensions [mm]
110 x 48 x 73
DIN IEC 68-2-27
20 g (11 ms)
DIN IEC 68-2-6:
5 g (10...2000 Hz)
Display Range (°F)
-43.6...233.6
Display range [°F]
-43.6...233.6
Electrical Design
PNP / NPN
File Number UL
E174189
Frequency At The End Point FRP (Hz)
1...10000
Frequency at the end point FRP [Hz]
1...10000
Housing
Rectangular
In Steps of (°F)
0.1
In steps of [°F]
0.1
Inputs
Counter Reset
IO-Link Revision
1.1
Material
stainless steel (1.4408 / 316); stainless steel (1.4404 / 316L); PC; PBT+PC-GF30
Materials (Wetted Parts)
stainless steel (1.4404 / 316L); PEEK; carbon fiber PEEK; FKM
Max. load [Ω]
500
Max. voltage drop switching output DC [V]
2
Maximum Load (Ω)
500
Maximum Voltage Drop Switching Output DC (V)
2
Measuring Principle
Magnetic-inductive
Measuring Range (°F)
-4...194
Measuring range [°F]
-4...194
Media
Conductive Liquids; Water; Water-based Media
Medium Temperature (°F)
-4...194
Medium temperature [°F]
-4...194
Min. process cycle time [ms]
8
Minimum Process Cycle Time (Ms)
8
MTTF (Years)
114
MTTF [years]
114
Number of Analog Outputs
1
Number of Digital Outputs
2
Number of inputs and outputs
Number of digital outputs: 2; Number of analog outputs: 1
Operating Voltage (V)
18...30 DC
Operating voltage [V]
18...30 DC; (to SELV/PELV)
Output Function
Normally Open / Closed
Overload Protection
Yes
Pack quantity
1 pcs.
Permanent Current Rating of Switching Output DC (Ma)
100
Permanent current rating of switching output DC [mA]
100
Power-on Delay Time (S)
5
Power-on delay time [s]
5
Process Connection
threaded connection 1 / 2" NPT Internal thread DN15
Process data analog
3
Process data binary
2
Protection
IP 65; IP 67
Protection Class
III
Pulse Length (S)
0.001...2
Pulse length [s]
0.001...2
Pulse Output
Flow Rate Meter
Pulse Value
0.001...99990000 I
Repeatability
± 0, 2 % MEW
Required master port class
A
Reset Point Rp (°F)
-4...193.3
Reset point rP [°F]
-4...193.3
Resolution (°F)
0.1
Resolution [°F]
0.1
Response Time (S)
15
Response time [s]
< 0.25; (dAP = 0, T09)
Reverse Polarity Protection
Yes
SDCI Standard
IEC 61131-9
Set Point SP (°F)
-3.3...194
Set point SP [°F]
-3.3...194
Short-circuit Protection
Yes
SIO mode
Yes
Special feature
Gold-plated contacts
Start-up Delay (S)
0...50
Start-up delay [s]
0...50
Storage Temperature (°F)
-13...176
Storage temperature [°F]
-13...176
Total Number of Outputs
2
Transmission type
COM2 (38, 4 kBaud)
Type of Short-circuit Protection
Yes (Non-latching)
- Precise measurement of flow, consumption and medium temperature
- High accuracy, repeatability and measurement dynamics
- With switching output, analog output and pulse output
- Clearly readable color display with red/green color change
- No inlet and output pipe lengths required
PLCs have evolved over the years to become crucial components for driving industrial automation. This post provides insights into the PLCs to help you understand how they work. Remember that you need to pick the right PLC for your system and ensure it is installed by an expert for proper performance.
Read MoreWhen selecting a PLC for industrial application, it is prudent to consider your system requirements and targeted control. It is also prudent to work with a technical expert and only acquire the PLC that guarantees better results.
Read MoreBrand
Browning
Model
1109362
Brand
Flowtrend
Model
180472
Brand
Flowtrend
Model
40MRTCV
Brand
Schunk
Model
1451153
Brand
Thomson Linear
Model
511P15C3NC
Brand
Thomson Linear
Model
511P35E1N
Brand
EXAIR
Model
4780