Accuracy (In The Measuring Range)
± (0, 8 % MW + 0, 5 % MEW)
Accuracy [K]
± 2, 5 (Q > 5 l/min)
Accuracy Class
-
Ambient Temperature (°C)
-10...60
Ambient temperature [°C]
-10...60
Analog Current Output (Ma)
4...20
Analog current output [mA]
4...20; (scalable)
Analog End Point (°C)
0...80
Analog end point [°C]
0...80
Analog Start Point (°C)
-20...60
Analog start point [°C]
-20...60
Analog Voltage Output (V)
0...10
Analog voltage output [V]
0...10; (scalable)
Communication Interface
IO-Link
Connector
1 x M12; coding: A; Contacts: gold-plated
Current Consumption (Ma)
95
Current consumption [mA]
95; (24 V)
Damping Process Value dAP (S)
0...5
Damping process value dAP [s]
0...5
Delay Time Programmable Ds, Dr (S)
0...50
Delay time programmable dS, dr [s]
0...50
Dimensions (mm)
Ø 54 / L = 110
Dimensions [mm]
Ø 54 / L = 110
DIN IEC 68-2-27
20 g (11 ms)
DIN IEC 68-2-6
5 g (10...2000 Hz)
Display Unit
6 x LED, green (l / min, m³ / h, l, m³, 10³, °C)
Dp
Pressure Loss
Dynamic Response T05 / T09 (S)
T09 = 20 (Q > 5 l / min)
Dynamic response T05 / T09 [s]
T09 = 20 (Q > 5 l/min)
Electrical Design
PNP / NPN
Housing
Tubular
In Steps of (°C)
0.2
In steps of [°C]
0.2
Inlet Pipe Length
3 x DN
Inputs
Counter Reset
Installation
Connection to pipe by means of an adapter
IO-Link Revision
1.1
Material
stainless steel (1.4404 / 316L); PBT-GF20; PC; FKM; TPE
Materials (Wetted Parts)
stainless steel (1.4404 / 316L); PEEK; FKM
Max. load [Ω]
500
Max. voltage drop switching output DC [V]
2
Maximum Allowable Error
± 1, 5 % FS
Maximum Load (Ω)
500
Maximum Voltage Drop Switching Output DC (V)
2
Measured Values
alphanumeric display, 4-digit
Measuring Principle
Magnetic-inductive
Measuring Range (°C)
-20...80
Measuring range [°C]
-20...80
Media
Conductive Liquids; Water; Water-based Media
Medium Temperature (°C)
-10...70
Medium temperature [°C]
-10...70
Min. load resistance [Ω]
2000
Min. process cycle time [ms]
5
Minimum Load Resistance (Ω)
2000
Minimum Process Cycle Time (Ms)
5
Model Number
001MI
MTTF (Years)
145
MTTF [years]
145
Number of Analog Outputs
1
Number of Digital Outputs
2
Number of inputs and outputs
Number of digital outputs: 2; Number of analog outputs: 1
Operating Voltage (V)
18...30 DC
Operating voltage [V]
18...30 DC; (to SELV/PELV)
Outlet Pipe Length
1 x DN
Output Function
Normally Open / Closed
Overload Protection
Yes
Pack quantity
1 pcs.
Permanent Current Rating of Switching Output DC (Ma)
200
Permanent current rating of switching output DC [mA]
200
Power-on Delay Time (S)
5
Power-on delay time [s]
5
Process Connection
threaded connection G 3 / 4 external thread DN20 flat seal
Process data analog
3
Process data binary
2
Programming
alphanumeric display, 4-digit
Protection
IP 67
Protection Class
III
Pulse Length (S)
0, 005...2
Pulse length [s]
0, 005...2
Pulse Output
Flow Rate Meter
Pulse Value
0.00001...50 000 m³
Q (Min)
0, 01 m³ / h
Repeatability
± 0, 2% MEW
Required master port class
A
Reset Point Rp (°C)
-19.6...79.6
Reset point rP [°C]
-19.6...79.6
Resolution (°C)
0.2
Resolution [°C]
0.2
Response Time (S)
0.15
Response time [s]
0.15; (dAP = 0, T19)
Reverse Polarity Protection
Yes
SDCI Standard
IEC 61131-9
Set Point SP (°C)
-19.2...80
Set point SP [°C]
-19.2...80
Short-circuit Protection
Yes
SIO mode
Yes
Special feature
Gold-plated contacts
Storage Temperature (°C)
-25...80
Storage temperature [°C]
-25...80
Switching Status
2 x LED, yellow
Total Number of Outputs
2
Transmission type
COM2 (38, 4 kBaud)
Type of Short-circuit Protection
Yes (Non-latching)
- Operating voltage 18...30 DC
- (according to EN 50178 SELV/PELV) V
- PNP/NPN
- M12 Connector
- Gold-plated contacts
- totaliser function, for industrial applications
The industrial sensor is an industrial device category used to serve its stated function within industrial automation equipment. It is incorporated into equipment arrangements where that general function is needed. The configuration details in the list identify this cataloged item and should be considered with the product technical documentation and applicable machine requirements. Catalog number SM7000 distinguishes this item in the equipment record. This paragraph provides general device context only; product-specific technical details are limited to the listed source information.
PLCs have evolved over the years to become crucial components for driving industrial automation. This post provides insights into the PLCs to help you understand how they work. Remember that you need to pick the right PLC for your system and ensure it is installed by an expert for proper performance.
Read MoreWhen selecting a PLC for industrial application, it is prudent to consider your system requirements and targeted control. It is also prudent to work with a technical expert and only acquire the PLC that guarantees better results.
Read MoreBrand
Cleveland
Model
C81016
Brand
Senco
Model
AX13EAC360
Brand
Dormer Pramet
Model
A13053/64
Brand
RAB Lighting
Model
ALEDXL5TWMN
Brand
SKF Seals
Model
11344
Brand
U.S.Tsubaki
Model
H160B27
Brand
Dodge
Model
SN-513X60MM