SMF550

Image for Illustration purposes only. Actual product may vary

View in markdown

IFM SMF550 SMG65KGFFRKG/UST Magnetic-inductive flow meter

MODEL SMF550

BRAND

IFM

SKU

96944381

UOM

each

$3,002.67 Each

Prices are subject to change

FREE SHIPPING ON ORDERS OVER $100

Select Quantity

GET A QUOTE

Returnable: Yes

Accuracy (K)

± 1 (v > 0, 5 m / s)

Accuracy [K]

± 1 (v > 0, 5 m/s)

Accuracy Class

0, 5

Analog Current Output (Ma)

4...20

Analog current output [mA]

4...20; (skalierbar)

Analog End Point (µS/Cm)

20000...100000

Analog end point [µS/cm]

20000...100000

Analog Start Point (µS/Cm)

0...80000

Analog start point [µS/cm]

0...80000

Binary Switching Information

8

BLOB

Binary Large Object Transfer

Communication Interface

IO-Link

Conductivity

32

Connector

1 x M12; coding: A; Contacts: gold-plated

Current Consumption (Ma)

250

Current consumption [mA]

250; (24V)

Damping Process Value dAP (S)

0...5

Damping process value dAP [s]

0...5

Diagnostic functions

Direction of flow detection; liquid detection

Dimensions (mm)

Ø 154 / L = 140

Dimensions [mm]

Ø 154 / L = 140

DIN IEC 68-2-27

20 g (18ms)

DIN IEC 68-2-6

5 g (10...2000Hz)

Electrical Design

PNP / NPN

Factory setting

M³/h; °C; μS/cm

Flow

32

Housing

Tubular

In The Range of 100...20000 µS/Cm

±10% MW

In The Range of 20000...100000 µS/Cm

±20% MW

Inlet Pipe Length

5 x DN

IO-Link Revision

1.1.3

Materials (Wetted Parts)

Pipe section: PFA; electrodes: stainless steel (1.4435 / 316L)

Max. load [Ω]

500

Max. voltage drop switching output DC [V]

2

Maximum Load (Ω)

500

Maximum Voltage Drop Switching Output DC (V)

2

Measuring Principle

Magnetic-inductive

Measuring Range (µS/Cm)

100...100000

Measuring range [µS/cm]

100...100000

Media

Conductive Liquids; Water; Water-based Media

Medium Temperature (°C)

-20...150

Medium temperature [°C]

-20...150

Min. process cycle time [ms]

1.9

Minimum Process Cycle Time (Ms)

1.9

Model Number

SMF

MTTF (Years)

82

MTTF [years]

82

Nominal Diameter

DN65 (2 1 / 2“)

Number of Analog Outputs

1

Number of Digital Outputs

2

Operating Status

LED ring, three-color

Operating Voltage (V)

18...32 DC

Operating voltage [V]

18...32 DC

Outlet Pipe Length

2 x DN

Overload Protection

Yes

Pack quantity

1 pcs.

Permanent Current Rating of Switching Output DC (Ma)

100

Permanent current rating of switching output DC [mA]

100

Power-on Delay Time (S)

< 5

Power-on delay time [s]

< 5

Process Connection

Ifm-specific Device Flange

Process data analog

6

Process data binary

8

Protection

IP 67; IP 69

Protection Class

III

Pulse Length (S)

0.00005...2

Pulse length [s]

0.00005...2

Pulse Output

Flow Rate Meter

Pulse Value

0.004...99999000 I

Repeatability

± 5% MW

Repeatability [K]

± 0, 5 (v > 0, 5 m/s)

Required master port class

A

Resolution (µS/Cm)

1

Resolution [µS/cm]

1

Resolution of Analog Output

0.38 µA

Response Time (S)

< 2

Response time [s]

< 0.3

Reverse Polarity Protection

Yes

SDCI Standard

IEC 61131-9

Short-circuit Protection

Yes

SIO mode

Yes

Special feature

Gold-plated contacts

Standard

± (0, 5 % MW + 1, 5 mm / s)

Status

4

Surface Characteristics Ra/Rz of The Wetted Parts

Ra < 0.4 μm

Switching Frequency DC (Hz)

0...10000

Switching frequency DC [Hz]

0...10000

Temperature

32

Total Number of Inputs and Outputs

2

Total Number of Outputs

2

Totalizer

32

Transmission type

COM3 (230, 4 kBaud)

Type of Short-circuit Protection

Yes (Non-latching)

with Optional Factory Calibration (Availability Is Being Planned)

± (0, 2 % MW + 2 mm / s)

  • Magnetic-inductive flow meter (SM Foodmag series) for the food and beverage industry
  • Measured variables: flow rate, total volume, temperature, conductivity and fluid detection
  • Reduced cabling by combining supply voltage and output signals via an M12 connection
  • Housing design increases shock and vibration resistance

Aug. 15, 2019

PLCs have evolved over the years to become crucial components for driving industrial automation. This post provides insights into the PLCs to help you understand how they work. Remember that you need to pick the right PLC for your system and ensure it is installed by an expert for proper performance.

Read More

 
Aug. 14, 2019

When selecting a PLC for industrial application, it is prudent to consider your system requirements and targeted control. It is also prudent to work with a technical expert and only acquire the PLC that guarantees better results.

Read More

 
Recently Viewed
046166

#128031

Brand

Dodge

Model

046166

$28.42 Each
Free Shipping orders over $100
070937

#128228

Brand

Dodge

Model

070937

$1,561.48 Each Add to cart for a lower price
Free shipping
20E000FS

#6266066

Brand

Drillco

Model

20E000FS

$29.49 Each
Free Shipping orders over $100
012418

#97211355

Brand

Walter

Model

012418

$2.07 Each
Free Shipping orders over $100
73A110C

#6271454

Brand

Drillco

Model

73A110C

$20.93 Each
Free Shipping orders over $100
66278WH2

#1980098

Brand

Hydraulic Technologies

Model

66278WH2

$477.33 Each
Free shipping
6040MB

#6420958

Brand

Timken

Model

6040MB

$2,287.86 Each
Free shipping
33461-2

#5071446

Brand

Timken

Model

33461-2

$84.76 Each
Free Shipping orders over $100