Accuracy (K)
± 1 (v > 0, 5 m / s)
Accuracy [K]
± 1 (v > 0, 5 m/s)
Analog Current Output (Ma)
4...20
Analog current output [mA]
4...20; (skalierbar)
Analog End Point (µS/Cm)
20000...100000
Analog end point [µS/cm]
20000...100000
Analog Start Point (µS/Cm)
0...80000
Analog start point [µS/cm]
0...80000
Binary Switching Information
8
BLOB
Binary Large Object Transfer
Communication Interface
IO-Link
Conductivity
32
Connector
1 x M12; coding: A; Contacts: gold-plated
Current Consumption (Ma)
250
Current consumption [mA]
250; (24V)
Damping Process Value dAP (S)
0...5
Damping process value dAP [s]
0...5
Diagnostic functions
Direction of flow detection; liquid detection
Dimensions (mm)
Ø 220.1 / L = 200
Dimensions [mm]
Ø 220.1 / L = 200
DIN IEC 68-2-27
20 g (18ms)
DIN IEC 68-2-6
5 g (10...2000Hz)
Display Range (µS/Cm)
0...10000000
Display range [µS/cm]
0...10000000
Display unit
Ft / °F
Electrical Design
PNP / NPN
Factory setting
°F
File Number UL
E174189
Flow
32
Housing
Tubular
In The Range of 100...20000 µS/Cm
±10% MW
In The Range of 20000...100000 µS/Cm
±20% MW
Inlet Pipe Length
5 x DN
IO-Link Revision
1.1.3
Materials (Wetted Parts)
Pipe section: PFA; electrodes: stainless steel (1.4435 / 316L)
Max. load [Ω]
500
Max. voltage drop switching output DC [V]
2
Maximum Load (Ω)
500
Maximum Voltage Drop Switching Output DC (V)
2
Measuring Principle
Magnetic-inductive
Measuring Range (µS/Cm)
100...100000
Measuring range [µS/cm]
100...100000
Media
Conductive Liquids; Water; Water-based Media
Min. process cycle time [ms]
1.9
Minimum Process Cycle Time (Ms)
1.9
MTTF (Years)
81
MTTF [years]
81
Nominal Diameter
DN125 (5“)
Number of Analog Outputs
1
Number of Digital Outputs
2
Operating Status
LED ring, three-color
Operating Voltage (V)
18...32 DC
Operating voltage [V]
18...32 DC
Outlet Pipe Length
2 x DN
Overload Protection
Yes
Pack quantity
1 pcs.
Permanent Current Rating of Switching Output DC (Ma)
100
Permanent current rating of switching output DC [mA]
100
Power-on Delay Time (S)
< 5
Power-on delay time [s]
< 5
Process Connection
Ifm-specific Device Flange
Process data analog
6
Process data binary
8
Process Value
full graphics TFT display, multi-color 3, 5" 320 x 240 Pixel
Protection
IP 67; IP 69
Protection Class
III
Pulse Length (S)
0.00005...2
Pulse length [s]
0.00005...2
Pulse Output
Flow Rate Meter
Pulse Value
0.038...99990000 I
Repeatability
± 5% MW
Repeatability [K]
± 0, 5 (v > 0, 5 m/s)
Required master port class
A
Resolution (µS/Cm)
1
Resolution [µS/cm]
1
Resolution of Analog Output
0.38 µA
Response Time (S)
< 2
Response time [s]
< 0.3
Reverse Polarity Protection
Yes
SDCI Standard
IEC 61131-9
Short-circuit Protection
Yes
SIO mode
Yes
Special feature
Gold-plated contacts
Standard
± (0, 5 % MW + 1, 5 mm / s)
Status
4
Surface Characteristics Ra/Rz of The Wetted Parts
Ra < 0.4 μm
Switching Frequency DC (Hz)
0...10000
Switching frequency DC [Hz]
0...10000
Temperature
32
Total Number of Inputs and Outputs
2
Total Number of Outputs
2
Totalizer
32
Transmission type
COM3 (230, 4 kBaud)
Type of Short-circuit Protection
Yes (Non-latching)
with Optional Factory Calibration (Availability Is Being Planned)
± (0, 2 % MW + 2 mm / s)
- Magnetic-inductive flow meter (SM Foodmag series) for the food and beverage industry
- Measured variables: flow rate, total volume, temperature, conductivity and fluid detection
- Easy to set up thanks to app-based menu, guided installation and hygienic pushbuttons
- Reduced cabling by combining supply voltage and output signals via an M12 connection
- Housing design increases shock and vibration resistance
PLCs have evolved over the years to become crucial components for driving industrial automation. This post provides insights into the PLCs to help you understand how they work. Remember that you need to pick the right PLC for your system and ensure it is installed by an expert for proper performance.
Read MoreWhen selecting a PLC for industrial application, it is prudent to consider your system requirements and targeted control. It is also prudent to work with a technical expert and only acquire the PLC that guarantees better results.
Read More