We never sell your data to third parties
IFM IG6215 IGK4012-FRKG/IO/US-104 Inductive sensor with IO-Link
MODEL IG6215
$120.23 Each
Prices are subject to change
FREE SHIPPING ON ORDERS OVER $100
Select Quantity
Returnable: Yes
Ambient Temperature (°C)
-40...85
Ambient temperature [°C]
-40...85
Binary Switching Information
2
Communication Interface
IO-Link
Connector
1 x M12; coding: A
Correction Factor
steel: 1 / stainless steel: 0.7 / brass: 0.5 / aluminum: 0.5 / copper: 0.4
Current Consumption (Ma)
< 15
Current consumption [mA]
< 15
Device Status
4
Dimensions (mm)
M18 x 1 / L = 60
Dimensions [mm]
M18 x 1 / L = 60
Electrical Design
PNP / NPN
Embedded Software Included
Yes
Enclosure Type
Type 1
File Number UL
E174191
Housing
Threaded Type
Hysteresis (% of Sr)
3...15
Hysteresis [% of Sr]
3...15
IO-Link Revision
1.1
Linearity Error IO-Link (%)
± 2
Linearity error IO-Link [%]
± 2; (of the final value of the measuring range)
Max. voltage drop switching output DC [V]
2.5
Maximum Voltage Drop Switching Output DC (V)
2.5
Measuring Range IO-Link (mm)
1.3...13
Measuring range IO-Link [mm]
1.3...13
Min. process cycle time [ms]
3.2
Minimum Process Cycle Time (Ms)
3.2
Mounting
Non-flush Mountable
MTTF (Years)
599
MTTF [years]
599
Operating Voltage (V)
10...30 DC
Operating voltage [V]
10...30 DC
Output Function
Normally Open / Closed
Overload Protection
Yes
Pack quantity
1 pcs.
Permanent Current Rating of Switching Output DC (Ma)
100
Permanent current rating of switching output DC [mA]
100
Process Value
16
Protection
IP 65; IP 66; IP 67; IP 68; IP 69K
Protection Class
III
Repeatability Analog Output (%)
± 1
Repeatability analog output [%]
± 1; (of the final value of the measuring range)
Required master port class
A
Reverse Polarity Protection
Yes
SDCI Standard
IEC 61131-9
Short-circuit Protection
Yes
SIO mode
Yes
Switch Point IO-Link (mm)
2.4...12.1
Switch point IO-Link [mm]
2.4...12.1; (configurable)
Switching Frequency DC (Hz)
300
Switching frequency DC [Hz]
300
Switching Status
4 x LED, yellow lights
Ta
-25...70 °C
Temperature Coefficient (%/K Vom MEW)
± 0, 3
Temperature coefficient [%/K vom MEW]
± 0, 3
Temperature Drift
± 10 %
Thread Designation
M18 X 1
Transmission type
COM2 (38, 4 kBaud)
Voltage Supply
Limited Voltage / Current
- For a precise position monitoring on machines
- Wide operating temperature range
- Very high repeatability
PLCs have evolved over the years to become crucial components for driving industrial automation. This post provides insights into the PLCs to help you understand how they work. Remember that you need to pick the right PLC for your system and ensure it is installed by an expert for proper performance.
Read MoreWhen selecting a PLC for industrial application, it is prudent to consider your system requirements and targeted control. It is also prudent to work with a technical expert and only acquire the PLC that guarantees better results.
Read MoreBrand
Goulds
Model
4BF1JBK0
Brand
Timken
Model
29502-5960
Brand
RAB Lighting
Model
GN3LED26YADW
Brand
Goulds
Model
2ST2C4D4
Brand
Timken
Model
3MM206WI SUM
Brand
U.S.Tsubaki
Model
16B15F-1F