Ambient Temperature (°C)
-25...80
Ambient temperature [°C]
-25...80
Binary Switching Information
2
Communication Interface
IO-Link
Connector
1 x M12; coding: A
Correction Factor
steel: 1 / stainless steel: 1 / brass: 0.4 / aluminum: 0.4 / copper: 0.3
Current Consumption (Ma)
< 17
Current consumption [mA]
< 17
Device Status
4
Dimensions (mm)
40 x 40 x 54
Dimensions [mm]
40 x 40 x 54
Electrical Design
PNP / NPN
Embedded Software Included
Yes
Enclosure Type
Type 1
File Number UL
E174191
Housing
Rectangular
Hysteresis (% of Sr)
3...15
Hysteresis [% of Sr]
3...15
IO-Link Revision
1.1
Linearity Error IO-Link (%)
± 2
Linearity error IO-Link [%]
± 2; (of the final value of the measuring range)
Max. voltage drop switching output DC [V]
2.5
Maximum Voltage Drop Switching Output DC (V)
2.5
Measuring Range IO-Link (mm)
2.6...26
Measuring range IO-Link [mm]
2.6...26
Min. process cycle time [ms]
3.2
Minimum Process Cycle Time (Ms)
3.2
Mounting
Non-flush Mountable
MTTF (Years)
577
MTTF [years]
577
Operating Voltage (V)
10...30 DC
Operating voltage [V]
10...30 DC
Output Function
Normally Open / Closed
Overload Protection
Yes
Pack quantity
1 pcs.
Permanent Current Rating of Switching Output DC (Ma)
100
Permanent current rating of switching output DC [mA]
100
Process Value
16
Protection
IP 67
Protection Class
III
Repeatability Analog Output (%)
± 1
Repeatability analog output [%]
± 1; (of the final value of the measuring range)
Required master port class
A
Reverse Polarity Protection
Yes
SDCI Standard
IEC 61131-9
Short-circuit Protection
Yes
SIO mode
Yes
Switch Point IO-Link (mm)
4.9...24.3
Switch point IO-Link [mm]
4.9...24.3; (configurable)
Switching Frequency DC (Hz)
100
Switching frequency DC [Hz]
100
Switching Status
4 x LED, yellow lights
Ta
-25...70 °C
Temperature Coefficient (%/K Vom MEW)
± 0, 3
Temperature coefficient [%/K vom MEW]
± 0, 3
Temperature Drift
± 10 %
Transmission type
COM2 (38, 4 kBaud)
Voltage Supply
Limited Voltage / Current
- Long sensing range for use in conveying
- IO-Link communication and additional digital switching signal
- Five selectable positions of the sensing face
PLCs have evolved over the years to become crucial components for driving industrial automation. This post provides insights into the PLCs to help you understand how they work. Remember that you need to pick the right PLC for your system and ensure it is installed by an expert for proper performance.
Read MoreWhen selecting a PLC for industrial application, it is prudent to consider your system requirements and targeted control. It is also prudent to work with a technical expert and only acquire the PLC that guarantees better results.
Read MoreBrand
Rollway
Model
7305 B
Brand
Dichtomatik
Model
75115200
Brand
Dormer Pramet
Model
5966765
Brand
Champion
Model
738-5/8
Brand
Timken
Model
UCT213
Brand
Bridgeport
Model
LR-46CGC
Brand
Timken
Model
6006-ZZ