We never sell your data to third parties
IFM LR7320 LR0000--BN34AQPKG/US Continuous level sensor (guided wave radar)
MODEL LR7320
$548.68 Each
Prices are subject to change
FREE SHIPPING ON ORDERS OVER $100
Select Quantity
Returnable: Yes
Active Range A (mm)
L-40
Active range A [mm]
L-40
Ambient Temperature (°C)
-25...60
Ambient temperature [°C]
-25...60
Communication Interface
IO-Link
Connector
1 x M12; coding: A; Contacts: gold-plated
Current Consumption (Ma)
< 25
Current consumption [mA]
< 25
Dielectric Constant of The Medium
> 5
Electrical Design
PNP / NPN
File Number UL
E174191
Hysteresis (mm)
> 5
Hysteresis [mm]
> 5
In Steps of (mm)
5
In steps of [mm]
5
Inactive Range I1 / I2 (mm)
30 / 10
Inactive range I1 / I2 [mm]
30 / 10
IO-Link Revision
1.1
Material
stainless steel (1.4301 / 304); stainless steel (1.4404 / 316L); FKM; PEI
Max. voltage drop switching output DC [V]
2.5
Maximum Voltage Drop Switching Output DC (V)
2.5
Measuring Error (mm)
± 7
Measuring error [mm]
± 7
Measuring Principle
Guided Wave Radar
Media
Liquids
Min. process cycle time [ms]
3.2
Minimum Process Cycle Time (Ms)
3.2
MTTF (Years)
286
MTTF [years]
286
Number of Digital Outputs
2
Number of inputs and outputs
Number of digital outputs: 2
Offset Error (mm)
5
Offset error [mm]
5
Operating Voltage (V)
18...30 DC
Operating voltage [V]
18...30 DC
Output Function
Normally Open / Closed
Output Signal
switching signal; IO-Link
Overload Protection
Yes
Pack quantity
1 pcs.
Permanent Current Rating of Switching Output DC (Ma)
200
Permanent current rating of switching output DC [mA]
200
Power-on Delay Time (S)
< 3
Power-on delay time [s]
< 3
Probe Length L (mm)
100...2000
Probe length L [mm]
100...2000
Process Connection
threaded connection 3 / 4" NPT external thread
Process data analog
3
Process data binary
2
Process Temperature (°C)
-25...80
Process temperature [°C]
-25...80; (90 < 1 h ; see note under remarks)
Protection
IP 68; IP 69K
Protection Class
III
Recommended media
Water; water-based media
Repeatability (mm)
5
Repeatability [mm]
5
Required master port class
A
Reset Point Rp (mm)
10... L-35
Reset point rP [mm]
10... L-35
Resolution (mm)
1
Resolution [mm]
1
Reverse Polarity Protection
Yes
Sampling Rate (Hz)
4
Sampling rate [Hz]
4
SDCI Standard
IEC 61131-9
Set Point SP (mm)
15...L-30
Set point SP [mm]
15...L-30
Short-circuit Protection
Yes
SIO mode
Yes
Special feature
Gold-plated contacts
Storage Temperature (°C)
-40...85
Storage temperature [°C]
-40...85
Temperature Drift Per 10 K
± 0.2 %
Total Number of Outputs
2
Transmission type
COM2 (38, 4 kBaud)
Type of Short-circuit Protection
Yes (Non-latching)
- For the reliable level control in tanks and containers
- Suitable for water and water-based media
- Modular system consisting of evaluation unit and probe
- Probes may be cut to length for application flexibility
PLCs have evolved over the years to become crucial components for driving industrial automation. This post provides insights into the PLCs to help you understand how they work. Remember that you need to pick the right PLC for your system and ensure it is installed by an expert for proper performance.
Read MoreWhen selecting a PLC for industrial application, it is prudent to consider your system requirements and targeted control. It is also prudent to work with a technical expert and only acquire the PLC that guarantees better results.
Read MoreBrand
RAB Lighting
Model
A17-5T100/3PRS
Brand
Walter
Model
075006
Brand
Berkeley
Model
B87080
Brand
Dodge
Model
290058
Brand
Thomson Linear
Model
HD12B045-0500EXP2MMS
Brand
Thomson Linear
Model
512P55A3C
Brand
Goulds
Model
2BF20734V
Brand
Cle-Line
Model
C97336