We never sell your data to third parties
IFM PG1415 PG-006-REB12-MFRKG/US/ /P Pressure sensor with analogue display
MODEL PG1415
$634.04 Each
Prices are subject to change
FREE SHIPPING ON ORDERS OVER $100
Select Quantity
Returnable: Yes
Ambient Temperature (°C)
-25...70
Ambient temperature [°C]
-25...70
Analog Current Output (Ma)
4...20, invertible
Analog current output [mA]
4...20, invertible; (scalable)
Binary Switching Information Pressure
2
BLOB
Binary Large Object Transfer
Characteristics Deviation (% of The Span)
< ± 0, 5
Communication Interface
IO-Link
Connector
1 x M12; coding: A; Contacts: gold-plated
Current Consumption (Ma)
25...260
Current consumption [mA]
25...260
Damping for The Analog Output dAA (S)
0...99.99
Damping for the analog output dAA [s]
0...99.99
Damping Process Value dAP (S)
0...99.99
Damping process value dAP [s]
0...99.99
Device Status
LED, red / green
Dimensions (mm)
160 x 100 x 57
Dimensions [mm]
160 x 100 x 57
Display
display rotation: 320°
Display Unit
Bar; Psi
Display, Switching Output
0, 1
Electrical Design
PNP / NPN
Embedded Software Included
Yes
File Number UL
E174189
Housing
Manometer Housing
Hysteresis Deviation (% of The Span)
< ± 0, 15
Hysteresis deviation [% of the span]
< ± 0, 15; (Turn down 1:1 -25...80°C)
Integrated Watchdog
Yes
IO-Link Resolution Pressure (Bar)
0.0002
IO-Link resolution pressure [bar]
0.0002
IO-Link Revision
1.1
IO-Link, Analog Output
0, 2
LED Bar Graph
Multi-color; 72 Steps
Long-term Stability (% of The Span)
< ± 0, 1
Long-term stability [% of the span]
< ± 0, 1; (Turn down 1:1; per year)
Max. load [Ω]
500
Max. voltage drop switching output DC [V]
2
Maximum Load (Ω)
500
Maximum Voltage Drop Switching Output DC (V)
2
Measured Values
alphanumeric display, white 4-digit
Media
Liquids and Gases
Medium Temperature (°C)
-25...80
Medium temperature [°C]
-25...80; (higher temperature upon request)
Min. insulation resistance [MΩ]
100; (500 V DC)
Min. pressure cycles
100 million
Min. process cycle time [ms]
1.3
Min. response time of switching output (dAP) [ms]
3
Minimum Insulation Resistance (MΩ)
100
Minimum Pressure Cycles
100 million
Minimum Process Cycle Time (Ms)
1.3
Minimum Response Time of Switching Output (dAP) (Ms)
3
MTTF (Years)
115
MTTF [years]
115
Number of Analog Outputs
1
Number of Digital Outputs
1
Number of inputs and outputs
Number of digital outputs: 1; Number of analog outputs: 1
Operating Voltage (V)
18...30 DC
Operating voltage [V]
18...30 DC
Output Function
Normally Open / Closed
Output Signal
switching signal; analog signal; IO-Link
Overload Protection
Yes
Pack quantity
1 pcs.
Permanent Current Rating of Switching Output DC (Ma)
100
Permanent current rating of switching output DC [mA]
100
Pointer
LED, white; 72 steps
Power-on Delay Time (S)
< 0.5
Power-on delay time [s]
< 0.5
Pressure
32
Process Connection
threaded connection G 1 / 2 external thread DIN EN 837-1
Protection
IP 67; IP 69
Protection Class
III
Repeatability (% of The Span)
< ± 0, 1
Required master port class
A
Restrictor Element Integrated
No (Can Be Retrofitted)
Reverse Polarity Protection
Yes
SDCI Standard
IEC 61131-9
Short-circuit Protection
Yes
SIO mode
Yes
Special feature
Gold-plated contacts
Step Response Time Analog Output (Ms)
7
Step response time analog output [ms]
7
Storage Temperature (°C)
-40...100
Storage temperature [°C]
-40...100
Switch Point Accuracy (% of The Span)
< ± 0, 5
Switch point accuracy [% of the span]
< ± 0, 5; (DIN EN IEC 62828-1; Turn down 1:1)
Switching Frequency DC (Hz)
125
Switching frequency DC [Hz]
125
Switching Status
LED, yellow
Temperature Coefficient Span (% of The Span / 10 K)
< ± 0, 25
Temperature coefficient span [% of the span / 10 K]
< ± 0, 25; (0...70 °C)
Temperature Coefficient Zero Point (% of The Span / 10 K)
< ± 0, 25
Temperature coefficient zero point [% of the span / 10 K]
< ± 0, 25; (0...70 °C)
Total Number of Outputs
2
Transmission type
COM3 (230, 4 kBaud)
Type of Pressure
Relative Pressure; Vacuum
Type of Short-circuit Protection
Yes (Non-latching)
- Manometer display, pressure switch and transmitter in one unit
- Excellent readability also over a long distance
- Rotatable display with LED indication for flexible visualisation
- Programmable switching output and scalable analog output
- Robust stainless steel housing for use in harsh industrial environments
PLCs have evolved over the years to become crucial components for driving industrial automation. This post provides insights into the PLCs to help you understand how they work. Remember that you need to pick the right PLC for your system and ensure it is installed by an expert for proper performance.
Read MoreWhen selecting a PLC for industrial application, it is prudent to consider your system requirements and targeted control. It is also prudent to work with a technical expert and only acquire the PLC that guarantees better results.
Read MoreBrand
Thomson Linear
Model
511H20D2DN
Brand
Thomson Linear
Model
512U45D3G2
Brand
Walter
Model
071111
Brand
Thomson Linear
Model
511P15C1ZC
Brand
Berkeley
Model
B87239
Brand
Remke
Model
110G0200A
Brand
Drillco
Model
445E138
Brand
IFM
Model
EVT001