We never sell your data to third parties
$836.00 Each
Prices are subject to change
FREE SHIPPING ON ORDERS OVER $100
Select Quantity
Returnable: Yes
Accuracy (K)
± 0.8 + (0.16 x (ambient temperature - medium temperature))
Accuracy [K]
± 0.8 + (0.16 x (ambient temperature - medium temperature))
Ambient Temperature (°C)
-25...70
Ambient temperature [°C]
-25...70
Analog Current Output (Ma)
4...20, invertible
Analog current output [mA]
4...20, invertible; (scalable)
Binary Switching Information Pressure
2
Binary Switching Information Temperature
2
BLOB
Binary Large Object Transfer
Characteristics Deviation (% of The Span)
< ± 0, 2
Communication Interface
IO-Link
Connector
1 x M12; coding: A; Contacts: gold-plated
Current Consumption (Ma)
25...260
Current consumption [mA]
25...260
Damping for The Analog Output dAA (S)
0...99.99
Damping for the analog output dAA [s]
0...99.99
Damping Process Value dAP (S)
0...99.99
Damping process value dAP [s]
0...99.99
Device Status
LED, red / green
Dimensions (mm)
155 x 100 x 57
Display
display rotation: 320°
Display Unit
bar; psi; °C; °F
Display, Switching Output
0, 2
Dynamic Response T05 / T09 (S)
< 55 / < 270
Dynamic response T05 / T09 [s]
< 55 / < 270; (DIN EN 60751 water ; > 0, 9 m/s)
Electrical Design
PNP / NPN
Embedded Software Included
Yes
File Number UL
E174189
Housing
Manometer Housing
Hysteresis Deviation (% of The Span)
< ± 0, 15
Hysteresis deviation [% of the span]
< ± 0, 15; (Turn down 1:1)
Integrated Watchdog
Yes
IO-Link Resolution Pressure (Bar)
0.0005
IO-Link resolution pressure [bar]
0.0005
IO-Link Resolution Temperature (K)
0.1
IO-Link resolution temperature [K]
0.1
IO-Link Revision
1.1
IO-Link, Analog Output
0, 1
LED Bar Graph
Multi-color; 72 Steps
Linearity Deviation (% of The Span)
< ± 0, 15
Linearity deviation [% of the span]
< ± 0, 15; (Turn down 1:1)
Long-term Stability (% of The Span)
< ± 0, 1
Long-term stability [% of the span]
< ± 0, 1; (Turn down 1:1; per year)
Max. load [Ω]
500
Max. voltage drop switching output DC [V]
2
Maximum Load (Ω)
500
Maximum Voltage Drop Switching Output DC (V)
2
Measured Values
alphanumeric display, white 4-digit
Measuring Element
Ceramic-capacitive Pressure Measuring Cell
Medium Temperature (°C)
-25...150
Medium temperature [°C]
-25...150
Min. insulation resistance [MΩ]
100; (500 V DC)
Min. process cycle time [ms]
1.3
Min. response time of switching output (dAP) [ms]
3
Minimum Insulation Resistance (MΩ)
100
Minimum Pressure Cycles
100 million
Minimum Process Cycle Time (Ms)
1.3
Minimum Response Time of Switching Output (dAP) (Ms)
3
MTTF (Years)
115
MTTF [years]
115
NO Dead Space
Yes
Notes on the accuracy / deviation
For further details see section Diagrams and graphs
Number of Analog Outputs
1
Number of Digital Outputs
1
Number of inputs and outputs
Number of digital outputs: 1; Number of analog outputs: 1
Operating Voltage (V)
18...30 DC
Operating voltage [V]
18...30 DC
Output Function
Normally Open / Closed
Output Signal
switching signal; analog signal; IO-Link
Overload Protection
Yes
Permanent Current Rating of Switching Output DC (Ma)
100
Permanent current rating of switching output DC [mA]
100
Pointer
LED, white; 72 steps
Power-on Delay Time (S)
< 0.5
Power-on delay time [s]
< 0.5
Pressure
32
Process Connection
Threaded Connection G 1 External Thread Mit Dichtkontur Aseptoflex Vario
Protection
IP 67; IP 69
Protection Class
III
Repeatability (% of The Span)
< ± 0, 1
Repeatability [K]
± 0, 2
Required master port class
A
Resolution of Display (K)
1
Resolution of display [K]
1
Reverse Polarity Protection
Yes
SDCI Standard
IEC 61131-9
Short-circuit Protection
Yes
SIO mode
Yes
Special feature
Gold-plated contacts
Step Response Time Analog Output (Ms)
7
Step response time analog output [ms]
7
Storage Temperature (°C)
-40...100
Storage temperature [°C]
-40...100
Switch Point Accuracy (% of The Span)
< ± 0, 2
Switch point accuracy [% of the span]
< ± 0, 2; (DIN EN IEC 62828-1; Turn down 1:1)
Switching Frequency DC (Hz)
125
Switching frequency DC [Hz]
125
Switching Status
LED, yellow
Temperature
32
Temperature Range
Total Deviation
Tightening Torque (Nm)
35
Total Number of Outputs
2
Transmission type
COM3 (230, 4 kBaud)
Type of Pressure
Relative Pressure; Vacuum
Type of Short-circuit Protection
Yes (Non-latching)
X
Temperature
Y
Total Deviation
- Manometer display, pressure switch and transmitter in one unit
- Excellent readability also over a long distance
- Rotatable display with LED indication for flexible visualisation
- Hygienic, robust stainless steel housing for the requirements of the food and beverage industry
- Flush process connection for use in CIP and SIP processes
PLCs have evolved over the years to become crucial components for driving industrial automation. This post provides insights into the PLCs to help you understand how they work. Remember that you need to pick the right PLC for your system and ensure it is installed by an expert for proper performance.
Read MoreWhen selecting a PLC for industrial application, it is prudent to consider your system requirements and targeted control. It is also prudent to work with a technical expert and only acquire the PLC that guarantees better results.
Read MoreBrand
Greenfield Threading
Model
330147
Brand
Berkeley
Model
SL5P4EJ-06
Brand
RAB Lighting
Model
LLD4B
Brand
Bondhus
Model
43207
Brand
Schunk
Model
194122
Brand
Littelfuse
Model
702R1C3.8