IFM PI2305 PI-004-REZ02-MFRKG/US/ /P Flush pressure sensor with display
MODEL PI2305
$1,219.24 Each
Prices are subject to change
FREE SHIPPING ON ORDERS OVER $100
Select Quantity
Returnable: Yes
Ambient Temperature (°C)
-25...65
Ambient temperature [°C]
-25...80
Analog Current Output (Ma)
4...20, invertible
Analog current output [mA]
4...20, invertible; (scalable)
Characteristics Deviation (% of The Span)
< ± 0, 2
Communication Interface
IO-Link
Connector
1 x M12; coding: A; Contacts: 4, gold-plated
Current Consumption (Ma)
< 45
Current consumption [mA]
3.6...21
Damping for The Analog Output dAA (S)
0.01...99.99
Damping for the analog output dAA [s]
0.01...99.99
Damping Process Value dAP (S)
0...30
Damping process value dAP [s]
0...30
Diaphragm Diameter (mm)
47.5
Diaphragm diameter [mm]
47.5
Dimensions (mm)
Ø 50 / L = 163
Dimensions [mm]
Ø 50 / L = 163
Display unit
Psi
Display, Switching Output
0, 2
Electrical Design
PNP / NPN
Fill Fluid for Pressure Transfer
NEOBEE (food grade, FDA compliant)
Function Display
alphanumeric display, 4-digit
Housing
Tubular
Hysteresis Deviation (% of The Span)
< ± 0, 15
Hysteresis deviation [% of the span]
< ± 0, 15; (Turn down 1:1)
Integrated Watchdog
Yes
IO-Link Revision
1
IO-Link, Analog Output
0, 15
Linearity Deviation (% of The Span)
< ± 0, 15
Linearity deviation [% of the span]
< ± 0, 15; (Turn down 1:1)
Long-term Stability (% of The Span)
< ± 0, 1
Long-term stability [% of the span]
< ± 0, 1; (Turn down 1:1; per year)
Material
stainless steel (1.4404 / 316L); stainless steel (1.4435 / 316L); PBT; PEI; PFA
Materials (Wetted Parts)
Stainless Steel (1.4435 / 316L)
Max. load [Ω]
300
Max. voltage drop switching output DC [V]
2
Maximum Load (Ω)
(Ub - 10 V) / 20 mA
Maximum Voltage Drop Switching Output DC (V)
2
Measured Values
alphanumeric display, 4-digit
Medium Temperature (°C)
-20...200
Medium temperature [°C]
-20...200; (-20...90 < 0 bar)
Min. insulation resistance [MΩ]
100; (500 V DC)
Min. pressure cycles
10 million
Min. process cycle time [ms]
2.3
Min. response time of switching output (dAP) [ms]
3
Minimum Insulation Resistance (MΩ)
100
Minimum Pressure Cycles
10 million
Minimum Process Cycle Time (Ms)
2.3
Minimum Response Time of Switching Output (dAP) (Ms)
3
MTTF (Years)
149
MTTF [years]
149
Number of Analog Outputs
1
Number of Digital Outputs
2
Number of inputs and outputs
Number of digital outputs: 2; Number of analog outputs: 1
Operating Voltage (V)
18...32 DC
Operating voltage [V]
20...32 DC
Output Function
Normally Open / Closed
Output Signal
switching signal; analog signal; IO-Link
Overload Protection
Yes
Pack quantity
1 pcs.
Permanent Current Rating of Switching Output DC (Ma)
250
Permanent current rating of switching output DC [mA]
250
Power-on Delay Time (S)
0.5
Power-on delay time [s]
1
Process Connection
Clamp DN50 (2") DIN 32676 (ISO 2852)
Process data analog
1
Process data binary
2
Protection
IP 67; IP 68; IP 69K
Protection Class
III
Repeatability (% of The Span)
< ± 0, 1
Required master port class
A
Reverse Polarity Protection
Yes
Short-circuit Protection
Yes
SIO mode
Yes
Special feature
Gold-plated contacts
Step Response Time Analog Output (Ms)
7
Step response time analog output [ms]
45
Storage Temperature (°C)
-25...100
Storage temperature [°C]
-25...100
Surface Characteristics Ra/Rz of The Wetted Parts
Ra < 0.38 µm
Switch Point Accuracy (% of The Span)
< ± 0, 2
Switch point accuracy [% of the span]
< ± 0, 2; (Turn down 1:1)
Switching Frequency DC (Hz)
125
Switching frequency DC [Hz]
125
Switching Status
LED, yellow
Temperature Coefficient Span (% of The Span / 10 K)
< ± 0, 15
Temperature coefficient span [% of the span / 10 K]
< ± 0, 15; (0...200 °C)
Temperature Coefficient Zero Point (% of The Span / 10 K)
< ± 0, 2
Temperature coefficient zero point [% of the span / 10 K]
< ± 0, 2; (0...200 °C)
Total Number of Outputs
2
Transmission type
COM2 (38, 4 kBaud)
Type of Pressure
Relative Pressure; Vacuum
Type of Short-circuit Protection
Yes (Non-latching)
- 2 wires DC / 3 wires DC PNP/NPN
- Function programmable
- Diaphragm diameter: 47.5 mm
- Fill fluid for pressure transfer: medical white oil (suited for use in food, Fda compliant)
- Connector
- 4-digit alphanumeric display
- 2-wire connection technology: analogue output
- 3-wire connection technology: 2 outputs
- OUT1 = switching output
- OUT2 = switching output or analogue output
PLCs have evolved over the years to become crucial components for driving industrial automation. This post provides insights into the PLCs to help you understand how they work. Remember that you need to pick the right PLC for your system and ensure it is installed by an expert for proper performance.
Read MoreWhen selecting a PLC for industrial application, it is prudent to consider your system requirements and targeted control. It is also prudent to work with a technical expert and only acquire the PLC that guarantees better results.
Read MoreBrand
Dodge
Model
WSTU-IP-400LE
Brand
Dodge
Model
334841
Brand
Hubbell Wiring
Model
HBL2152STRTR
Brand
Timken
Model
24148EMBW33W45AC3
Brand
Thomson Linear
Model
HD24B026-0250ELP1EMS
Brand
Cleveland
Model
C81905
Brand
Berliss
Model
09422