We never sell your data to third parties
IFM PG2458 PG-25BREB12-MFRKG/US/ /P Pressure sensor with analogue display
MODEL PG2458
$729.96 Each
Prices are subject to change
FREE SHIPPING ON ORDERS OVER $100
Select Quantity
Returnable: Yes
Ambient Temperature (°C)
-20...80
Ambient temperature [°C]
-20...80
Analog Current Output (Ma)
4...20, invertible
Analog current output [mA]
4...20, invertible; (scalable)
Characteristics Deviation (% of The Span)
< ± 0, 25 (BFSL) / < ± 0, 5 (LS)
Connector
1 x M12; coding: A; Contacts: gold-plated
Current Consumption (Ma)
< 70
Current consumption [mA]
< 70; (24 V)
Damping for The Analog Output dAA (S)
0.01...30
Damping for the analog output dAA [s]
0.01...30
Damping Process Value dAP (S)
0.01...30
Damping process value dAP [s]
0.01...30
Dimensions (mm)
169 x 100 x 57
Dimensions [mm]
169 x 100 x 57
Display Unit
2 x LED, green
Electrical Design
PNP / NPN
Function Display
alphanumeric display, red 4-digit
Hysteresis Deviation (% of The Span)
< ± 0, 25
Hysteresis deviation [% of the span]
< ± 0, 25; (Turn down 1:1)
Integrated Watchdog
Yes
Long-term Stability (% of The Span)
< ± 0, 1
Long-term stability [% of the span]
< ± 0, 1; (Turn down 1:1; per 6 months)
Materials (Wetted Parts)
Al2O3 (ceramics); FKM; stainless steel (1.4404 / 316L)
Max. load [Ω]
(Ub - 10 V) / 20 mA
Max. voltage drop switching output DC [V]
2
Maximum Load (Ω)
(Ub - 10 V) / 20 mA
Maximum Voltage Drop Switching Output DC (V)
2
Measured Values
alphanumeric display, red 4-digit
Media
Liquids and Gases
Medium Temperature (°C)
-25...80
Medium temperature [°C]
-25...80
Min. insulation resistance [MΩ]
100; (500 V DC)
Min. pressure cycles
100 million
Minimum Insulation Resistance (MΩ)
100
Minimum Pressure Cycles
100 million
MTTF (Years)
103
MTTF [years]
103
Number of Analog Outputs
1
Number of Digital Outputs
1
Number of inputs and outputs
Number of digital outputs: 1; Number of analog outputs: 1
Operating Voltage (V)
18...32 DC
Operating voltage [V]
18...32 DC
Output Function
Normally Open / Closed
Output Signal
Switching Signal; Analog Signal
Overload Protection
Yes
Pack quantity
1 pcs.
Permanent Current Rating of Switching Output DC (Ma)
250
Permanent current rating of switching output DC [mA]
250
Power-on Delay Time (S)
6
Power-on delay time [s]
6
Process Connection
Threaded Connection G 1 / 2 External Thread
Protection
IP 67; IP 69K
Protection Class
III
Repeatability (% of The Span)
< ± 0, 1
Response Time (Ms)
< 9
Response time [ms]
< 9
Restrictor Element Integrated
No (Can Be Retrofitted)
Reverse Polarity Protection
Yes
Short-circuit Protection
Yes
Special feature
Gold-plated contacts
Step Response Time Analog Output (Ms)
28
Step response time analog output [ms]
28
Storage Temperature (°C)
-40...100
Storage temperature [°C]
-40...100
Switch Point Accuracy (% of The Span)
< ± 0, 5
Switch point accuracy [% of the span]
< ± 0, 5; (Turn down 1:1)
Switch Points
LED ring, red
Switching Frequency DC (Hz)
75
Switching frequency DC [Hz]
75
Switching Status
LED, yellow
Temperature Coefficient Span (% of The Span / 10 K)
< ± 0, 2
Temperature coefficient span [% of the span / 10 K]
< ± 0, 2; (0...70 °C)
Temperature Coefficient Zero Point (% of The Span / 10 K)
< ± 0, 2
Temperature coefficient zero point [% of the span / 10 K]
< ± 0, 2; (0...70 °C)
Total Number of Outputs
2
Type of Pressure
Relative Pressure
Type of Short-circuit Protection
Yes (Non-latching)
with Scale
Yes
- analog display, pressure switch and transmitter in one unit
- Excellent readability also over a long distance
- Rotatable display with LED bar graph for switch point indication
- Programmable switching output and scalable analog output
- Robust stainless steel housing for use in harsh industrial environments
PLCs have evolved over the years to become crucial components for driving industrial automation. This post provides insights into the PLCs to help you understand how they work. Remember that you need to pick the right PLC for your system and ensure it is installed by an expert for proper performance.
Read MoreWhen selecting a PLC for industrial application, it is prudent to consider your system requirements and targeted control. It is also prudent to work with a technical expert and only acquire the PLC that guarantees better results.
Read MoreBrand
Remke
Model
RSM-20105-E
Brand
Browning
Model
1108851
Brand
Flowtrend
Model
2122859
Brand
Thomson Linear
Model
511P20B3V
Brand
Flowtrend
Model
H76926
Brand
Walter
Model
07F508
Brand
Timken
Model
VR511
Brand
Flowtrend
Model
3139-BO