We never sell your data to third parties
IFM PG2734 PG-010KREA01-MFRKG/US/ /P Flush pressure sensor with analogue display
MODEL PG2734
$921.36 Each
Prices are subject to change
FREE SHIPPING ON ORDERS OVER $100
Select Quantity
Returnable: Yes
Ambient Temperature (°C)
-25...80
Ambient temperature [°C]
-25...80
Analog Current Output (Ma)
4...20, invertible
Analog current output [mA]
4...20, invertible; (scalable)
Analog End Point (Kpa)
150...1600
Analog end point [kPa]
150...1600
Analog Start Point (Kpa)
-100...1350
Analog start point [kPa]
-100...1350
Characteristics Deviation (% of The Span)
< ± 0, 2
Connector
1 x M12; coding: A; Contacts: 4, gold-plated
Current Consumption (Ma)
< 70
Current consumption [mA]
< 70; (24 V)
Damping for The Analog Output dAA (S)
0.01...30
Damping for the analog output dAA [s]
0.01...30
Damping Process Value dAP (S)
0.01...30
Damping process value dAP [s]
0.01...30
Dimensions (mm)
153 x 100 x 57
Dimensions [mm]
153 x 100 x 57
Display Unit
2 x LED, green
Electrical Design
PNP / NPN
Function Display
alphanumeric display, red 4-digit
Hysteresis Deviation (% of The Span)
< ± 0, 15
Hysteresis deviation [% of the span]
< ± 0, 15; (Turn down 1:1)
In Steps of (Kpa)
1
In steps of [kPa]
1
Integrated Watchdog
Yes
Linearity Deviation (% of The Span)
< ± 0, 15
Linearity deviation [% of the span]
< ± 0, 15; (Turn down 1:1)
Long-term Stability (% of The Span)
< ± 0, 1
Long-term stability [% of the span]
< ± 0, 1; (Turn down 1:1; per year)
MAWP (for Applications According To CRN) (Bar)
50
MAWP (for applications according to CRN) [bar]
50
Max. load [Ω]
(Ub - 10 V) / 20 mA
Max. voltage drop switching output DC [V]
2
Maximum Load (Ω)
(Ub - 10 V) / 20 mA
Maximum Voltage Drop Switching Output DC (V)
2
Measured Values
alphanumeric display, red 4-digit
Medium Temperature (°C)
-25...125
Medium temperature [°C]
-25...125; (145 max. 1h)
Min. insulation resistance [MΩ]
100; (500 V DC)
Min. pressure cycles
100 million
Minimum Insulation Resistance (MΩ)
100
Minimum Pressure Cycles
100 million
MTTF (Years)
100
MTTF [years]
100
NO Dead Space
Yes
Number of Analog Outputs
1
Number of Digital Outputs
1
Number of inputs and outputs
Number of digital outputs: 1; Number of analog outputs: 1
Operating Voltage (V)
18...32 DC
Operating voltage [V]
18...32 DC
Output Function
Normally Open / Closed
Output Signal
Switching Signal; Analog Signal
Overload Protection
Yes
Pack quantity
1 pcs.
Permanent Current Rating of Switching Output DC (Ma)
250
Permanent current rating of switching output DC [mA]
250
Power-on Delay Time (S)
6
Power-on delay time [s]
6
Process Connection
Threaded Connection G 1 External Thread Mit Dichtkontur Aseptoflex Vario
Protection
IP 67; IP 69K
Protection Class
III
Repeatability (% of The Span)
< ± 0, 1
Reset Point Rp (Kpa)
-100...1598
Reset point rP [kPa]
-100...1598
Response Time (Ms)
< 10
Response time [ms]
< 10
Reverse Polarity Protection
Yes
Set Point SP (Kpa)
-98...1600
Set point SP [kPa]
-98...1600
Short-circuit Protection
Yes
Special feature
Gold-plated contacts
Step Response Time Analog Output (Ms)
25
Step response time analog output [ms]
25
Storage Temperature (°C)
-40...100
Storage temperature [°C]
-40...100
Switch Point Accuracy (% of The Span)
< ± 0, 2
Switch point accuracy [% of the span]
< ± 0, 2; (Turn down 1:1)
Switch Points
LED ring, red
Switching Frequency DC (Hz)
50
Switching frequency DC [Hz]
50
Switching Status
LED, yellow
Temperature Coefficient Span (% of The Span / 10 K)
< ± 0, 15
Temperature coefficient span [% of the span / 10 K]
< ± 0, 15; (0...70 °C)
Temperature Coefficient Zero Point (% of The Span / 10 K)
< ± 0, 05
Temperature coefficient zero point [% of the span / 10 K]
< ± 0, 05; (0...70 °C)
Total Number of Outputs
2
Type of Pressure
Relative Pressure; Vacuum
Type of Short-circuit Protection
Yes (Non-latching)
- Electronic pressure sensor
- with analogue display
- DC PNP/NPN
- Suitable for all standard Cip and Sip processes
- Analogue display 0...350° rotatable
- Resolution 0.25%
- Pointer not visible when unit disconnected
- no dead space
- Connector
- analogue display
- 4-digit alphanumeric display
- 2 outputs
- OUT1 = switching output
- OUT2 = analogue output
PLCs have evolved over the years to become crucial components for driving industrial automation. This post provides insights into the PLCs to help you understand how they work. Remember that you need to pick the right PLC for your system and ensure it is installed by an expert for proper performance.
Read MoreWhen selecting a PLC for industrial application, it is prudent to consider your system requirements and targeted control. It is also prudent to work with a technical expert and only acquire the PLC that guarantees better results.
Read MoreBrand
Whitney Tool
Model
01582
Brand
WEG
Model
JCCB07-2P/2R
Brand
Timken
Model
H313
Brand
RAB Lighting
Model
A22-5T320/MVS
Brand
Berkeley
Model
BVM33-3-2-102
Brand
Flowtrend
Model
5144A
Brand
Drillco
Model
1000F135