We never sell your data to third parties
IFM PF1509 PF-1-1BREA12-MFRKG/US//P Pressure sensor with display
MODEL PF1509
$500.50 Each
Prices are subject to change
FREE SHIPPING ON ORDERS OVER $100
Select Quantity
Returnable: Yes
Accuracy (K)
± 2 + (0, 045 x ( Ambient temperature - Medium temperature ))
Accuracy [K]
± 2 + (0, 045 x ( Ambient temperature - Medium temperature ))
Ambient Temperature (°C)
-25...80
Ambient temperature [°C]
-25...80
Analog Current Output (Ma)
4...20
Analog current output [mA]
4...20; (scalable 1:10)
Analog Voltage Output (V)
0...10
Analog voltage output [V]
0...10; (scalable 1:10)
Binary Switching Information Pressure
2
Binary Switching Information Temperature
2
Characteristics Deviation (% of The Span)
< ± 0, 5
Communication Interface
IO-Link
Connector
1 x M12; coding: A; Contacts: 4, gold-plated
Current Consumption (Ma)
15...40
Current consumption [mA]
15...40; (240 at max. load current)
Damping for The Analog Output dAA (S)
0...99.99
Damping for the analog output dAA [s]
0...99.99
Damping Process Value dAP (S)
0...99.99
Damping process value dAP [s]
0...99.99
Device Status
4
Dimensions (mm)
Ø 34 / L = 117.8
Dimensions [mm]
Ø 34 / L = 117.8
Display Unit
2x LED, green (mbar, kPa)
Display, Switching Output
0, 25
Dynamic Response T05 / T09 (S)
< 10 / < 45
Dynamic response T05 / T09 [s]
< 10 / < 45; (DIN EN 60751 water; > 0, 9 m/s)
Electrical Design
PNP / NPN
Embedded Software Included
Yes
Housing
Tubular
Hysteresis Deviation (% of The Span)
< ± 0, 15
Hysteresis deviation [% of the span]
< ± 0, 15; (Turn down 1:1)
Integrated Watchdog
Yes
IO-Link Resolution Pressure (Mbar)
0.5
IO-Link resolution pressure [mbar]
0.5
IO-Link Resolution Temperature (K)
0.2
IO-Link resolution temperature [K]
0.2
IO-Link Revision
1.1
IO-Link, Analog Output
0
Linearity Deviation (% of The Span)
< ± 0, 15
Linearity deviation [% of the span]
< ± 0, 15; (Turn down 1:1)
Long-term Stability
< ± 0, 1
Max. load [Ω]
500
Max. voltage drop switching output DC [V]
2
Maximum Load (Ω)
500
Maximum Voltage Drop Switching Output DC (V)
2
Measured Values
alphanumeric display, red / green 4-digit
Measuring Element
Ceramic-capacitive Pressure Measuring Cell
Medium Temperature (°C)
-25...80
Min. insulation resistance [MΩ]
100; (500 V DC)
Min. load resistance [Ω]
2000
Min. pressure cycles
100 million
Min. process cycle time [ms]
1
Minimum Insulation Resistance (MΩ)
100
Minimum Load Resistance (Ω)
2000
Minimum Pressure Cycles
100 million
MTTF (Years)
245
MTTF [years]
245
NO Dead Space
Yes
Number of Analog Outputs
1
Number of Digital Outputs
2
Number of inputs and outputs
Number of digital outputs: 2; Number of analog outputs: 1
Operating Voltage (V)
18...32 DC
Operating voltage [V]
18...32 DC
Output Function
Normally Open / Closed
Output Signal
switching signal; analog signal; IO-Link
Overload Protection
Yes
Permanent Current Rating of Switching Output DC (Ma)
100
Permanent current rating of switching output DC [mA]
100
Power-on Delay Time (S)
0.5
Power-on delay time [s]
0.5
Pressure
16
Process Connection
Threaded Connection G 1 / 2 External Thread
Protection
IP 65; IP 67; IP 69
Protection Class
III
Repeatability (% of The Span)
< ± 0, 1
Repeatability [K]
± 0, 2
Required master port class
A
Response Time (Ms)
< 3
Response time [ms]
< 3
Reverse Polarity Protection
Yes
SDCI Standard
IEC 61131-9
Short-circuit Protection
Yes
SIO mode
Yes
Special feature
Gold-plated contacts
Step Response Time Analog Output (Ms)
3
Step response time analog output [ms]
3
Storage Temperature (°C)
-40...100
Storage temperature [°C]
-40...100
Switch Point Accuracy (% of The Span)
< ± 0, 5
Switch point accuracy [% of the span]
< ± 0, 5; (DIN EN IEC 62828-1; Turn down 1:1)
Switching Frequency DC (Hz)
< 170
Switching frequency DC [Hz]
< 170
Switching Status
2 x LED, yellow
Temperature
16
Temperature Coefficient Zero Point and Span (% of The Span / 10 K)
< ± 0, 1
Temperature coefficient zero point and span [% of the span / 10 K]
< ± 0, 1; (-25...80 °C)
Temperature Monitoring
Yes
Tightening Torque (Nm)
25
Tightening torque [Nm]
25
Total Number of Outputs
2
Transmission type
COM3 (230, 4 kBaud)
Type of Pressure
Relative Pressure; Vacuum
Type of Short-circuit Protection
Yes (Non-latching)
- Robust ceramic measuring cell integrated flush in the process connection
- process connection with versatile sealing options
- Alternating red/green display for clear indication of acceptable ranges
- The process connection can be rotated for optimum alignment
- Suitable for use in drinking water applications
PLCs have evolved over the years to become crucial components for driving industrial automation. This post provides insights into the PLCs to help you understand how they work. Remember that you need to pick the right PLC for your system and ensure it is installed by an expert for proper performance.
Read MoreWhen selecting a PLC for industrial application, it is prudent to consider your system requirements and targeted control. It is also prudent to work with a technical expert and only acquire the PLC that guarantees better results.
Read MoreBrand
FEIN
Model
32624094032
Brand
Thomson Linear
Model
HD24B026-0500CNO2EES
Brand
FEIN
Model
63131068010
Brand
Timken
Model
24600-2820
Brand
FEIN
Model
30712088029
Brand
Dodge
Model
NSTU-SCEZ-20M-SHSS
Brand
Dodge
Model
108345
Brand
Dichtomatik
Model
75054609